Setting up CO2 Corrections
Temperature, water vapor in the patient's breath, barometric pressure, and the proportions of O
and Helium in the mixture all influence CO
that the monitor is using the appropriate corrections.
Correction
Altitude
(M3014A only)
O
2
(M3014A only)
Humidity
N
O
2
(M3015A/B
microstream only)
Gas
(M3014A only)
Agent
(M3014A only)
Suppressing Sampling (not Mainstream CO2)
To temporarily stop sampling, in the
SmartKey if available.
Selecting
To re-start the pump, in the
Changing CO2 Alarms
This refers to CO
To change the etCO
Touch the high limit on the alarm limits menu key.
1
Choose the high alarm limit from the pop-up list that opens.
2
Touch the low limit on the alarm limits menu key.
3
Choose the low alarm limit from the pop-up list that opens.
4
Altitude is set during installation. The monitor automatically applies an
appropriate correction.
In the
Setup CO₂
100%, the default value is 20%.
At installation, the monitor is configured to automatically apply either Body
Temperature Pressure Saturated (BTPS) or Ambient Temperature Pressure
Dry (ATPD). To see which, go to the
look at
Hum. Corr
In the
Setup CO₂
in the ventilation gas mixture, you must turn this on.
If the N
O correction is not available in the
2
measurement in your MMS Extension does not require N
is setup with
In the
Setup CO₂
Helium or N
appropriate selection.
If the Gas correction is not available in the
measurement in your MMS Extension does not require N
correction or the N
In the
Setup CO₂
anesthetic agent (between 0.0% and 20.0%). If an anesthetic agent is present
in the ventilation gas mixture, you must select the appropriate concentration.
again before fifteen minutes have passed resets the timer to fifteen minutes.
Pump 15min Off
Setup CO₂
specific alarms. See the Alarms section for general alarm information.
2
alarm limits, in the
2
absorption. If values seem inaccurately high or low, check
2
menu, select
Oxy. Corr
or
Humidity Corr.
.
menu, select
N₂O Corr.
Gas Corr.
(see below).
menu, select
Gas Corr.
O is present in the ventilation gas mixture, you must make the
2
O correction is setup with
2
menu, select
Agt. Corr
Setup CO₂
menu, select
Pump 15min Off
menu, select
Pump On
.
menu:
Setup CO₂
14 Monitoring Carbon Dioxide
and select a value between 20% and
menu, and scroll down to
Setup CO₂
and turn on or off. If N
2
Setup CO₂
menu, the CO
O correction or it
2
and select
,
or turn off. If
Helium
N₂O
Setup CO₂
menu, the CO
O or Helium
2
N₂O Corr.
(see above).
and select the concentration of the
or use the
CO₂ Pump Off
N
O
2,
2
O is present
2
2
211