5. TROUBLESHOOTING
5.4

If no sampling data is obtained from DOSCP

No.
No sampling data is obtained. (The waveform is not detected.) The SSCNET communication driver is not set up correctly.
1
5.5

When SNETP is booted, "Not enogh memory" error occurs

No.
When SNETP is booted, "Not enogh memory" error occurs.
1
Phenomenon
Phenomenon
To perform communication over SSCNET, set up the
SSCNET communication driver.
To do this, refer to section 4.1 "SSCNET communication
driver setup procedure."
When SNETP is booted in the order of SW6RN-SNETP Ver.
00B or later and SW3RN-SNETP Ver. 00G or earlier,
SW3RN-SNETP displays the error given on the left and does
not start. Exit from SW3RN-SNETP.
5 − 6
Cause and remedy
Cause and remedy