Troubleshooting; Gsv[ ][ ]P Or Doscp Does Not Start Or It Is Terminated During Operation - Mitsubishi Electric MELSEC System Q Installation Manual

Motion controller
Hide thumbs Also See for MELSEC System Q:
Table of Contents

Advertisement

5. TROUBLESHOOTING

5. TROUBLESHOOTING
5.1

GSV[ ][ ]P or DOSCP does not start or it is terminated during operation

No
Phenomenon
.
When monitor, DOSCP or other application is
started from the menu, the following message
describing failure to find "sscpdr.dll" is displayed.
• Windows NT/2000
1
• Windows 98
The communication starting procedure causes the
following error and termination of the process.
2
Even when a Jump icon (monitor, digital oscilloscope
or other applications for performing communication)
of GSV[ ][ ]P is clicked on, jumping does not occur.
(However, no error is caused.)
3
Remedies for trouble are described in this section.
Refer to this section when you are in trouble.
Corresponding
Version
1) SNETP is not installed.
Even if communication with the CPU is not made
actually, SNETP must be installed.
Refer to section 3.4.6(1) to install the best SNETP.
If communication is made only with the A motion,
install SW3RN-SNETP.
• A list of applications for communication with the
SW3RN-
GSV[ ][ ]P
CPU is displayed.
SW3RN-
The following applications cause the phenomenon
DOSCP
described to the left. (Applications other than
those listed below operate without SNETP.)
GSV[ ][ ]P
SW3RN-DOSCP: Digital oscilloscope
2) The PATH specified as the long name has been
described in AUTOEXEC.BAT.
*: Long name: Folder name of 9 or more characters
Describe the SNETP PATH before the PATH
specified as the long name, and always add
"%PATH%" before the part where the long name has
been specified. It is not required if it has already
been described.
SW3RN-
(Example)
• Before change
GSV[ ][ ]P
SET PATH="C:\Program Files\ABC;"
SET PATH=%PATH%;C:\PROGRA~1\Snetp;
• After change
SET PATH=%PATH%;"C:\PROGRA~1\Snetp;"
SET PATH=%PATH%;"C:\Program Files\ABC;"
*: Always described the
(*1): Long name PATH
(*2): SNETP PATH
5 − 1
Cause and remedy
: Monitor, communication, program
editor, install, mechanical system
editor, test, backup, servo data
setting (for writing to servo
amplifier)
(*1)
(wiggly line) part.
(*2)