GE MiCOM P40 Agile Technical Manual page 453

Feeder management ied
Hide thumbs Also See for MiCOM P40 Agile:
Table of Contents

Advertisement

P14x
Object
Object
Variation
Number
Number
70
0
File Event - Any Variation
70
2
File Authentication
70
3
File Command
70
4
File Command Status
70
5
File Transfer
70
6
File Transfer Status
70
7
File Descriptor
80
1
Internal Indications
No Object (function code only)
No Object (function code only)
No Object (function code only)
Note:
A Default variation refers to the variation responded to when variation 0 is requested and/or in class 0, 1, 2, or 3 scans.
Note:
For static (non-change-event) objects, qualifiers 17 or 28 are only responded to when a request is sent with qualifiers 17 or
28, respectively. Otherwise, static object requests sent with qualifiers 00, 01, 06, 07, or 08, will be responded to with qualifiers
00 or 01. For change-event objects, qualifiers 17 or 28 are always responded to.
7.3.8.3
DNP3 INTERNAL INDICATIONS
The following table lists the DNP3.0 Internal Indications (IIN) and identifies those that are supported by the device.
The IIN form an information element used to convey the internal states and diagnostic results of a device. This
information can be used by a receiving station to perform error recovery or other suitable functions. The IIN is a
two-octet field that follows the function code in all responses from the device. When a request cannot be
processed due to formatting errors or the requested data is not available, the IIN is always returned with the
appropriate bits set.
Bit
Indication
0
All stations message received
P14xEd1-TM-EN-1
Function Codes (dec)
Description
22
(assign class)
1
(read)
22
(assign class)
29
(authenticate)
25
(open)
27
(delete)
26
(close)
30
(abort)
1
(read)
28
(get file info)
1
(read)
13
(cold restart)
14
(warm restart)
23
(delay meas.)
Set when a request is received with the destination address of the all stations
address (6553510). It is cleared after the next response (even if a response to a
global request is required).
This IIN is used to let the master station know that a "broadcast" message was
received by the relay.
Request
(Library will parse)
Qualifier Codes
(hex)
06
(no range, or all)
06
(no range, or all)
07, 08
(limited qty)
06
(no range, or all)
5b
(free-format)
5b
(free-format)
5b
(free-format)
5b
(free-format)
5b
(free-format)
00, 01
(start-stop)
Description
Octet 1
Chapter 18 - Communications
Response
(Library will respond with)
Function Codes
Qualifier Codes (hex)
(dec)
129 response
5B (free-format)
129 response
5B (free-format)
129 response
5B (free-format)
129 response
5B (free-format)
129 response
5B (free-format)
129 response
00, 01
(start-stop)
Supported
Yes
427

Hide quick links:

Advertisement

Table of Contents
loading