Measuring
No.
Item
instrument &
Input signals

2.10 EVR ADJUSTMENT

• After replacing the CCD image sensor or EEPROM, execute "Restore" in the EEPROM menu to write the initial value data
"TKC675_N.DAT"(U Ver.) or "TKC675_P.DAT"(E Ver.) in EEPROM before proceeding to the adjustment.
• Set the lens iris using the remote control software (refer to the instruction manual of the remote control software).
• To adjust items which require the adjustment software, select the required menu commands from the CAM. ADJ. menus using
the [Alt] key or mouse.
1
PLL control
• Oscilloscope
voltage
(H-rate 10:1)
adjustment
• It is not neces
sary to use the
infinity adjust
ment lens for
this adjustment.
2
Gain
• Gray scale chart
adjustment
(just scan)
• Oscilloscope
(H-rate 10:1)
3
OFD
• It is not neces-
adjustment
sary to use the
infinity adjust-
ment lens for
this adjustment.
• TV monitor
screen.
• Incandescent
lamp.
Smear
Monitor
2-5
Measuring point (
Adjustment parts (
Mode
Adjustment level (
TP1 (A-2B) [IF]
2Bh (PLL voltage)
2.75V DC
TP201 (B-1C) [PR]
LENS IRIS
0.7Vp-p
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
VIDEO output
36h (Y gain)
<U Ver. >
0.714Vp-p [100 IRE]
<E Ver.>
0.7Vp-p
Shutter
TV monitor screen
<U Ver.>
26h (V. sub)
1/100
Minimum blooming
<E Ver.>
1/60
Incandescent lamp
Blooming
Monitor
)
)
Adjustment procedure
)
1) Set S1-6 on the MD board to ON.
2) Adjust the PLL voltage data so that the volt-
age at TP1 [IF] is 2.75V DC.
3) Set S1-6 on the MD board to OFF.
1) Set lens iris so that the white level in the
center of the gray scale chart at TP201 [PR] is
0.7Vp-p.
2) Adjust the Y gain data so that the white level
in the center of the gray scale chart at VIDEO
output is 0.714 Vp-p [100 IRE] (U Ver.) or 0.7
Vp-p (E Ver.).
1) Set the shutter to "1/100" (U Ver.) or 1/60(E
Ver.).
2) Shoot an incandescent lamp and set the iris
to a position at which blooming becomes
most clear.
3) While observing the monitor screen, adjust
the V. sub data so that blooming disappears.
4) Set the shutter to "NORMAL".

Hide quick links: