*1: Soldered part must not have excess solder mound.
*2: The tail end of the contact must come into close contact with the cut
end of the insulating material. The contact must not be cutting in the
insulating material.
*3: Apply solder quickly so that the insulating material will not be
deformed by heat.
• Connector at the video camera and vision sensor
Use a connector applicable to the video camera or vision sensor
to be used.
(3) Precautions for cable preparation
The maximum cable length differs depending on the specifications of
the video camera and vision sensor to be used.
For details, refer to manuals for video camera and vision sensor.
When a cable length gets longer, video signals are attenuated, and
video images deteriorate.
When using a cable exceeding the length described in the following
table, it is recommended to correct video images using a video
signal amplifier.
Cable type
3C-2V
5C-2V
(4) Precautions for laying cable
Consider wiring using double-shielded coaxial cable in places that
are subject to large amounts of noise.
Double-shielded coaxial cable
Mitsubishi Cable ... 5C-2V-CCY
Grounding
The 5C-2V connector plug is applicable to double-shielded coaxial
cable.
Connect the 5C-2V connector plug to the coaxial cable inside a
double-shielded coaxial cable. Ground the shielded part outside a
double-shielded coaxial cable as shown in the above figure.
Cable length [m] (feet)
100 (328.1)
200 (656.2)
Enlarged view
of cable
Internal
conducter
Insulation
material
9
Sheath
Sheath
External
External
conductor
conductor
(Grounding)