Leader LV 5800 Instruction Manual

Multi monitor/ethernet
Hide thumbs Also See for LV 5800:

Advertisement

LV 5800
MULTI MONITOR
INSTRUCTION MANUAL
(ETHERNET)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LV 5800 and is the answer not in the manual?

Questions and answers

Summary of Contents for Leader LV 5800

  • Page 1 LV 5800 MULTI MONITOR INSTRUCTION MANUAL (ETHERNET)
  • Page 2: Table Of Contents

    Remote Control Using TELNET....................2 FTP File Transfer ........................3 Command Entry Procedure ...................... 4 TELNET Commands......................... 5 2.4.1 LV 5800 Commands (MULTI MONITOR) ................5 2.4.2 LV 58SER01A Commands (SDI INPUT) ................9 2.4.3 LV 58SER02 Commands (EYE PATTERN unit) .............. 25 2.4.4...
  • Page 3: Introduction

    1. INTRODUCTION INTRODUCTION This manual explains how to control an LV 5800 remotely over an Ethernet. For other explanations and notes, see the main LV 5800 instruction manual. About Network The remote control capability operation via the Ethernet is confirmed only under the local network environments;...
  • Page 4: Ethernet

    See the main LV 5800 instruction manual for Ethernet settings (*1) to the main frame. *1 For IP Address settings to LV 5800, press the SYS key to display the system menu. Then, press F・2 (PLATFORM SETUP) to display the tab menu to set up IP Address.
  • Page 5: Ftp File Transfer

    2. ETHERNET FTP File Transfer To transfer files from LV 5800 to PC connected to the network, FTP is used. For a description on how to start (*1) FTP, see the instruction manual that came with your PC. The user name and password cannot be changed on the LV 5800.
  • Page 6: Command Entry Procedure

    2. ETHERNET Command Entry Procedure The system of control commands used on the Ethernet network follows the menu structure. Reading this manual and the instruction manuals of each Unit of the LV 5800 will facilitate the process. ● Entry Method of the Command The entry method of the command is shown below.
  • Page 7: Telnet Commands

    2. ETHERNET TELNET Commands 2.4.1 LV 5800 Commands (MULTI MONITOR) ● Front Panel LV 5800 (MULTI MONITOR) Command Parameter1 Description DISPLAY Selects first area Selects second area Selects third area Selects fourth area Queries the selected area MULTI Selects multi screen display...
  • Page 8 2. ETHERNET ● PLATFORM SETUP (GENERAL SETUP) LV 5800 (MULTI MONITOR) Command Parameter1 Description SYS:PLATFORM:SOURCE_MODE SINGLE Sets the single input mode. MULTI Sets the multi input mode. (Doesn’t interlock with the line selection.) MULTI_LINE Sets the multi input mode. (Interlocks with the line selection.)
  • Page 9 2. ETHERNET ● PLATFORM SETUP (REMOTE) LV 5800 (MULTI MONITOR) Command Parameter1 Description SYS:PLATFORM:REMOTE_MODE Recalls the presets from No.1 to 8 by bit. BINARY Recalls the presets from No.1 to 60 by binary code. Queries the remote mode. SYS:PLATFORM:ALARM:POLARITY POSITIVE...
  • Page 10: System Information

    *1 Return value when REMOTE:REPLY is ON If the LV 5800 is in the factory default condition (REMOTE:REPLY = OFF), the LV 5800 does not return a value even when a command has an error during TELNET remote control. It only returns a value for queries using a “?”...
  • Page 11: Lv 58Ser01A Commands (Sdi Input)

    2. ETHERNET 2.4.2 LV 58SER01A Commands (SDI INPUT) ● UNIT SETUP (GENERAL SETUP) LV 58SER01A (SDI INPUT) Command Parameter1 Parameter2 Description SYS:UNIT:LINK_FORMAT 1,2,3,4 (*1) SINGLE Sets the link format to single link. DUAL Sets the link format to dual link. Sets the link format to 2048 ×...
  • Page 12 2. ETHERNET Command Parameter1 Parameter2 Description SYS:UNIT:MANUAL_FORMAT 1,2,3,4 720P/24 Sets the format to 720p/24 at the time of single link. 720P/23.98 Sets the format to 720p/23.98 at the time of single link. 525I/59.94 Sets the format to 525i/59.94 at the time of single link.
  • Page 13 2. ETHERNET ● UNIT SETUP (ERROR SETUP1) LV 58SER01A (SDI INPUT) Command Parameter1 Parameter2 Description SYS:UNIT:ERROR:TRS 1,2,3,4 Detects the TRS errors. Does not detect the TRS errors. Queries the presence of TRS error detection. SYS:UNIT:ERROR:HD_LINE 1,2,3,4 Detects the line number errors. Does not detect the line number errors.
  • Page 14 2. ETHERNET ● UNIT SETUP (ERROR SETUP2) LV 58SER01A (SDI INPUT) Command Parameter1 Parameter2 Description SYS:UNIT:ERROR:ANC:PARITY 1,2,3,4 Detects the parity errors in the ancillary data. Does not detect the parity errors in the ancillary data. Queries the presence of parity error detection in the ancillary data.
  • Page 15 2. ETHERNET ● UNIT SETUP (ERROR SETUP3) LV 58SER01A (SDI INPUT) Command Parameter1 Parameter2 Description SYS:UNIT:ERROR:GAMUT:LPF 1,2,3,4 HD1M_SD1M Sets the LPF for gamut error detection to 1 MHz. HD2.8M_SD1M Sets the LPF for gamut error detection to 2.8 MHz as for HD-SDI and to 1 MHz as for SD-SDI.
  • Page 16 2. ETHERNET ● UNIT SETUP (ERROR SETUP4) LV 58SER01A (SDI INPUT) Command Parameter1 Parameter2 Description SYS:UNIT:ERROR:FREEZE 1,2,3,4 Detects the freeze errors. Does not detect the freeze errors. Queries the presence of freeze error detection. SYS:UNIT:ERROR:FREEZE:UPPER 1,2,3,4 0 to 100 Sets the detection area (upper) for freeze error.
  • Page 17 2. ETHERNET ● UNIT SETUP (ERROR SETUP5) LV 58SER01A (SDI INPUT) Command Parameter1 Parameter2 Description SYS:UNIT:ERROR:LEVEL 1,2,3,4 Detects the level errors. Does not detect the level errors. Queries the presence of level error detection. SYS:UNIT:ERROR:LEVEL:RUMA:UPPER 1,2,3,4 -51 to 766 Sets the upper limit (mV) of luminance level.
  • Page 18 2. ETHERNET ● WFM - INTEN/SCALE LV 58SER01A (SDI INPUT) Command Parameter1 Description WFM:INTEN:WFM -128 to 127 Adjusts the intensity of the video waveforms. Queries the intensity of the video waveforms. WFM:COLOR WHITE Sets the waveform display color to white. GREEN Sets the waveform display color to green.
  • Page 19 2. ETHERNET Command Parameter1 Description WFM:SWEEP:H_MAG In case of line display, set the sweep magnification so that the waveform fits on the screen. In case of line display, set the sweep magnification to x10 with respect to x1. In case of line display, set the sweep magnification to x20 with respect to x1.
  • Page 20 2. ETHERNET Command Parameter1 Description WFM:BLANKING:NORMAL REMOVE Displays the active period for the component display. H_VIEW Displays the active period and the horizontal blanking period for the component display. V_VIEW Displays the active period and the vertical blanking period for the component display.
  • Page 21 2. ETHERNET ● VECTOR LV 58SER01A (SDI INPUT) Command Parameter1 Description VECTOR Displays vector waveforms. ● VECTOR - INTEN/SCALE LV 58SER01A (SDI INPUT) Command Parameter1 Description VECTOR:INTEN:VECTOR -128 to 127 Sets the intensity of the vector waveform. Queries the intensity of the vector waveform. VECTOR:COLOR WHITE Sets the waveform display color to white.
  • Page 22 2. ETHERNET ● VECTOR - COLOR SYSTEM LV 58SER01A (SDI INPUT) Command Parameter1 Description VECTOR:MATRIX COMPONENT Sets the color matrix to component display. COMPOSITE Sets the color matrix to pseudo-composite display. Queries the color matrix setting. VECTOR:MATRIX:COMPOSITE: AUTO Selects NTSC or PAL automatically when displaying the FORMAT pseudo-composite.
  • Page 23 2. ETHERNET ● PICTURE LV 58SER01A (SDI INPUT) Command Parameter1 Description PICTURE Displays the pictures. ● PICTURE - ADJUST LV 58SER01A (SDI INPUT) Command Parameter1 Description PICTURE:BRIGHT -30 to 30 Adjusts the brightness of the picture display (%). Queries the brightness of the picture display. PICTURE:CONTRAST 0.70 to 1.30 Adjusts the contrast of the picture display.
  • Page 24 2. ETHERNET Command Parameter1 Description PICTURE:LINE_NUMBER Example) Sets the line of the line select. 1 to 1125 (Depending on the format) Queries the selected line of the line select. ● PICTURE - DISPLAY LV 58SER01A (SDI INPUT) Command Parameter1 Description PICTURE:SIZE Displays the picture size optimized.
  • Page 25 Does not record the log when 5000 items are exceeded. Queries the operation that is taken when 5000 items are exceeded. MAKE Creates the error logs in the LV 5800 as a text file. ● STATUS - SDI ANALYSIS LV 58SER01A (SDI INPUT)
  • Page 26 2. ETHERNET ● STATUS - COUNTER LV 58SER01A (SDI INPUT) Command Parameter1 Description STATUS:COUNTER The error count is updated in unit of seconds, and it displays as number of times. FIELD The error count is updated in unit of fields, and it displays as number of times.
  • Page 27: Lv 58Ser02 Commands (Eye Pattern Unit)

    2. ETHERNET 2.4.3 LV 58SER02 Commands (EYE PATTERN unit) ● UNIT SETUP LV 58SER02 (EYE PATTERN unit) Command Parameter1 Parameter2 Description SYS:UNIT:ERROR:HD_AMP 1,2,3,4 (*1) Enables the amplitude error detection for HD. Disables the amplitude error detection for HD. Queries the presence of the amplitude error detection for HD.
  • Page 28 2. ETHERNET Command Parameter1 Parameter2 Description SYS:UNIT:ERROR:HD_TIMING_JIT:MAX 1,2,3,4 10 to 200 Sets the upper limit (%) of the timing jitter for HD. Queries the upper limit of the timing jitter for HD. SYS:UNIT:ERROR:HD_CURRENT_JIT 1,2,3,4 Detects the error of current jitter value for HD.
  • Page 29 2. ETHERNET Command Parameter1 Parameter2 Description SYS:UNIT:ERROR:SD_DELTA 1,2,3,4 Detects the error related to the difference between the rise time (Tr) and fall time (Tf) for SD. Does not detect the error (Tr-Tf) for Queries the presence of the error (Tr-Tf) detection for SD. SYS:UNIT:ERROR:SD_DELTA:MAX 1,2,3,4 40 to 140...
  • Page 30 2. ETHERNET ● EYE - EYE SETUP LV 58SER02 (EYE PATTERN unit) Command Parameter1 Description EYE:AUTO_MEASURE Automatically measures the eye pattern. Does not automatically measure the eye pattern. Queries the status of automatic measurement of eye pattern. EYE:GAIN:VAR Sets the gain of the eye pattern waveform to a constant value (×1).
  • Page 31 2. ETHERNET ● EYE - JITTER SETUP LV 58SER02 (EYE PATTERN unit) Command Parameter1 Description EYE:JITTER:PEAK_HOLD Holds the peak value of the jitter waveform. Does not hold the peak value of the jitter waveform. Queries the hold status of the peak value of the jitter waveform.
  • Page 32: Lv 58Ser03 Commands (Composite Video Input)

    2. ETHERNET 2.4.4 LV 58SER03 Commands (COMPOSITE VIDEO INPUT) ● LV 58SER03 (COMPOSITE VIDEO INPUT) Command Parameter1 Description Displays the video signal waveform. ● WFM - INTEN/SCALE LV 58SER03 (COMPOSITE VIDEO INPUT) Command Parameter1 Description WFM:INTEN:WFM -128 to 127 Adjusts the intensity of the video waveforms. Queries the intensity of the video waveforms.
  • Page 33 2. ETHERNET Command Parameter1 Description WFM:SWEEP:V_MAG In case of field display, set the sweep magnification so that the waveform fits on the screen. In case of field display, set the sweep magnification to x20 with respect to X1. In case of field display, set the sweep magnification to x40 with respect to X1.
  • Page 34 2. ETHERNET ● VECTOR - INTEN/SCALE LV 58SER03 (COMPOSITE VIDEO INPUT) Command Parameter1 Description VECTOR:INTEN:VECTOR -128 to 127 Sets the intensity of the vector waveform. Queries the intensity of the vector waveform. VECTOR:COLOR WHITE Sets the waveform display color to white. GREEN Sets the waveform display color to green.
  • Page 35 2. ETHERNET ● VECTOR - COLOR SYSTEM LV 58SER03 (COMPOSITE VIDEO INPUT) Command Parameter1 Description VECTOR:MATRIX:SETUP Sets the setup to exclude. 7.5P Sets the setup to 7.5%. Queries the setup value. VECTOR:MATRIX:COLORBAR 100P Sets the scale that maches the 100% color bar. Sets the scale that maches the 75% color bar.
  • Page 36 2. ETHERNET Command Parameter1 Description PICTURE:BIAS:R -0.30 to 0.30 Adjusts the bias of the R signal (×100%). Queries the bias of the R signal. PICTURE:BIAS:G -0.30 to 0.30 Adjusts the bias of the G signal (×100%). Queries the bias of the G signal. PICTURE:BIAS:B -0.30 to 0.30 Adjusts the bias of the B signal (×100%).
  • Page 37: Lv 58Ser04 Commands (Mpeg Decoder)

    2. ETHERNET 2.4.5 LV 58SER04 Commands (MPEG DECODER) ● UNIT SETUP LV 58SER04 (MPEG DECODER) Command Parameter1 Parameter2 Description SYS:UNIT:SEMI_AUTO 1,2,3,4 (*1) Sets the selection method of DECODE PID to an automatic setting. Sets the selection method of DECODE PID to a manual setting. Queries the selection method of DECODE PID.
  • Page 38 2. ETHERNET Command Parameter1 Parameter2 Description SYS:UNIT:ERROR:PCR 1,2,3,4 Detects the PCR error. Does not detect the PCR error. Queries the presence of detecting the PCR error. SYS:UNIT:ERROR:PCR:CYCLE 1,2,3,4 10 to 200 Sets the interval (msec) becoming the PCR error. Queries the interval becoming the PCR error.
  • Page 39 2. ETHERNET ● WFM - INTEN/SCALE LV 58SER04 (MPEG DECODER) Command Parameter1 Description WFM:INTEN:WFM -128 to 127 Adjusts the intensity of the video waveforms. Queries the intensity of the video waveforms. WFM:COLOR WHITE Sets the waveform display color to white. GREEN Sets the waveform display color to green.
  • Page 40 2. ETHERNET Command Parameter1 Description WFM:SWEEP:H_MAG In case of line display, set the sweep magnification so that the waveform fits on the screen. In case of line display, set the sweep magnification to x10 with respect to x1. ACTIVE In case of line display, magnifies and displays the waveform in the active interval.
  • Page 41 2. ETHERNET ● WFM - ARRANGE LV 58SER04 (MPEG DECODER) Command Parameter1 Description WFM:FILTER:NORMAL FLAT Sets the filter to Flat for the component display. LOWPASS Sets the filter to LPF for the component display. Queries the filter setting for the component display. WFM:FILTER:COMPOSITE FLAT Sets the filter to Flat and to parade display of the luminance...
  • Page 42 2. ETHERNET ● VECTOR LV 58SER04 (MPEG DECODER) Command Parameter1 Description VECTOR Displays vector waveforms. ● VECTOR - INTEN/SCALE LV 58SER04 (MPEG DECODER) Command Parameter1 Description VECTOR:INTEN:VECTOR -128 to 127 Sets the intensity of the vector waveform. Queries the intensity of the vector waveform. VECTOR:COLOR WHITE Sets the waveform display color to white.
  • Page 43 2. ETHERNET ● VECTOR - COLOR SYSTEM LV 58SER04 (MPEG DECODER) Command Parameter1 Description VECTOR:MATRIX COMPONENT Sets the color matrix to component display. COMPOSITE Sets the color matrix to pseudo-composite display. Queries the color matrix setting. VECTOR:MATRIX:COMPOSITE:FORMAT AUTO Selects NTSC or PAL automatically when displaying the pseudo-composite.
  • Page 44 2. ETHERNET ● PICTURE - MARKER LV 58SER04 (MPEG DECODER) Command Parameter1 Description PICTURE:MARKER:4_3 Displays the 4:3 aspect marker. Does not display the 4:3 aspect marker. Queries the presence of displaying the 4:3 aspect marker. PICTURE:MARKER:16_9 Displays the 16:9 aspect marker. Does not display the 16:9 aspect marker.
  • Page 45: Lv 58Ser40A Commands (Digital Audio)

    2. ETHERNET 2.4.6 LV 58SER40A Commands (DIGITAL AUDIO) ● UNIT SETUP LV 58SER40A (DIGITAL AUDIO) Command Parameter1 Parameter2 Description SYS:UNIT:EXT_BNC 1,2,3,4 (*1) INPUT Sets all rear BNC connector to input. OUTPUT Sets all rear BNC connector to output. Queries all rear BNC connector setting. SYS:UNIT:ERROR:LEVEL_OVER 1,2,3,4 Detects the level over error.
  • Page 46 2. ETHERNET ● AUDIO - CHANNEL SELECT LV 58SER40A (DIGITAL AUDIO) Command Parameter1 Description AUDIO:CH_SEL:NUMBER Sets the number of measurement channels to 8ch. 16CH Sets the number of measurement channels to 16ch. Queries the number of measurement channels. AUDIO:CH_SEL:DISPLAY 1_8CH Sets the channels that are measured to 1-8ch when the number of measurement channels is 8ch.
  • Page 47 2. ETHERNET Command Parameter1 Description AUDIO:METER:OVER_LEVEL -40.0 to 0.0 Sets the over level.(dBFS) Queries the over level. AUDIO:METER:WARNING_LEVEL -40.0 to 0.0 Sets the warning level. (dBFS) Queries the warning level. AUDIO:METER:REF_LEVEL -40.0 to 0.0 Sets the reference level. (dBFS) Queries the reference level. ●...
  • Page 48 2. ETHERNET Command Parameter1 Description AUDIO:LISSAJOU:MAP:MULTI_L3 CH1 to CH16 Sets the channel to be assigned to the L3 axis of the multi Lissajous waveform. Queries the channel to be assigned to the L3 axis of the multi Lissajous waveform. AUDIO:LISSAJOU:MAP:MULTI_R3 CH1 to CH16 Sets the channel to be assigned to the R3 axis of the multi Lissajous waveform.
  • Page 49 2. ETHERNET ● AUDIO - S.IMAGE SETUP LV 58SER40A (DIGITAL AUDIO) Command Parameter1 Description AUDIO:S_IMAGE:INTEN:S_IMAGE -128 to 127 Sets the intensity of the sound image waveform. Queries the intensity of the sound image waveform. AUDIO:S_IMAGE:INTEN:SCALE -8 to 7 Sets the intensity of the scale. Queries the intensity of the scale.
  • Page 50 2. ETHERNET ● AUDIO - STATUS SETUP LV 58SER40A (DIGITAL AUDIO) Command Parameter1 Description AUDIO:STATUS:DISPLAY DEFAULT Displays the status screen. CH_STATUS Displays the channel status screen. USER_BIT Displays the user bit screen. Queries the display formt of the status screen. AUDIO:DOLBY:E_META_PRM PRM1 to PRM8 Sets the program number in which metadata of the Dolby E...
  • Page 51 2. ETHERNET Command Parameter1 Description AUDIO:DOLBY:AUX_CH LTRT Sets the function of the AUX CH to LtRt. LORO Sets the function of the AUX CH to LoRo. MONO Sets the function of the AUX CH to MONO. MUTE Sets the function of the AUX CH to MUTE. Sets the function of the AUX CH.
  • Page 52: Ftp Commands

    2. ETHERNET FTP Commands Carries out the FTP command after carrying out the MAKE command of TELNET to retrieve each file by using the FTP. Example) Operation of retrieving a text file of the event log to a computer 1) Starts TELNET and carries out "MAKE LOG" of the TELNET command. 2) Starts FTP and carries out “GET”...
  • Page 53: Snmp

    3. SNMP SNMP Description SNMP (Simple Network Management Protocol) can be used to control the LV 5800 and notify SDI signal errors. The following sections describe how to set the LV 5800 and MIB (Management Information Base) when using SNMP.
  • Page 54: Setting The Lv 5800

    Be sure to disable the destinations that are not used. If you do not, it will cause unnecessary load in the communications. The default setting is "Disable." 5). Restart the LV 5800. 6). The standard SNMP trap “coldStart(0)” is sent when the LV 5800 starts up. Check that the trap is received by the SNMP manager.
  • Page 55: Mib

    The indications in the SUPPORT column in the tables are defined as follows: Supported as defined by the standard. ○ Only read is supported by the LV 5800 even though read and write are possible △ according to the standard.
  • Page 56 3. SNMP ● system group SYNTAX ACCESS SUPPORT sysDescr system.1 DisplayString ○ sysObjectID system.2 ObjectID ○ sysUpTime system.3 TimeTicks ○ sysContact (*1) system.4 DisplayString ○ sysName (*1) system.5 DisplayString ○ sysLocation (*1) system.6 DisplayString ○ sysServices system.7 INTEGER ○ *1 Set using up to 40 bytes. ●...
  • Page 57 3. SNMP ● ip group SYNTAX ACCESS SUPPORT ipForwarding ip.1 INTEGER ○ ipDefaultTTL ip.2 INTEGER ○ ipInReceives ip.3 Counter ○ ipInHdrErrors ip.4 Counter ○ ipInAddrErrors ip.5 Counter ○ ipForwDatagrams ip.6 Counter ○ ipInUnknownProtos ip.7 Counter ○ ipInDiscards ip.8 Counter ○ ipInDelivers ip.9 Counter...
  • Page 58 3. SNMP ● icmp group SYNTAX ACCESS SUPPORT icmpInMsgs icmp.1 Counter ○ icmpInErrors icmp.2 Counter ○ icmpInDestUnreachs icmp.3 Counter ○ icmpInTimeExcds icmp.4 Counter ○ icmpInParmProbs icmp.5 Counter ○ icmpInSrcQuenchs icmp.6 Counter ○ icmpInRedirects icmp.7 Counter ○ icmpInEchos icmp.8 Counter ○ icmpInEchoReps icmp.9 Counter...
  • Page 59 3. SNMP ● udp group SYNTAX ACCESS SUPPORT udpInDatagrams udp.1 Counter ○ udpNoPorts udp.2 Counter ○ udpInErrors udp.3 Counter ○ udpOutDatagrams udp.4 Counter ○ udpTable udp.5 Aggregate ○ udpEntry udpTable.1 Aggregate ○ udpLocalAddress udpEntry.1 IpAddress ○ udpLocalPort udpEntry.2 INTEGER ○ ●...
  • Page 60: Enterprise Mib

    For a description of how to use FTP, see section 2.2, “FTP File Transfer” in this Manual. ● Enterprise MIB Structure The enterprise MIB structure is shown below. On the LV 5800 that does not have option boards installed, the MIB for the options cannot be controlled. leader OBJECT IDENTIFIER ::= { enterprises 20111 }...
  • Page 61 3. SNMP ● l10basicTBL(1) group SYNTAX ACCESS VALUE/RANGE l10basDisplay l10basicTBL.1 INTEGER 1 = display1 2 = display2 3 = display3 4 = display4 l10basMulti l10basicTBL.2 INTEGER 1 = on 2 = off l10basInputTBL l10basicTBL.3 Aggregate l10basInputUnit l10basInputTBL.1 INTEGER 1 = unit1 2 = unit2 3 = unit3 4 = unit4...
  • Page 62 3. SNMP ● l10systemTBL(2) group LV 5800 (MULTI MONITOR) SYNTAX ACCESS VALUE/RANGE l10sysUnitTBL l10systemTBL.1 Aggregate l10sysUnitSetup (*1) l10sysUnitTBL.1 INTEGER 1 = unit1 2 = unit2 3 = unit3 4 = unit4 5 = unit5 6 = unit6 l10sysUnit1Info l10sysUnitTBL.2 INTEGER...
  • Page 63 3. SNMP SYNTAX ACCESS VALUE/RANGE l10sysUnitManualFormat l10sysUnitTBL.9 INTEGER 1 = 1080i/60 2 = 1080PsF/30 3 = 1080i/59.94 4 = 1080PsF/29.97 5 = 1080i/50 6 = 1080PsF/25 7 = 1080PsF/24 8 = 1080PsF/23.98 9 = 1080p/30 10 = 1080p/29.97 11 = 1080p/25 12 = 1080p/24 13 = 1080p/23.98 14 = 720p/60...
  • Page 64 3. SNMP SYNTAX ACCESS VALUE/RANGE l10sysPlatformAlarm1Unit l10sysPlatformTBL.12 INTEGER 1 = UNIT1 2 = UNIT2 3 = UNIT3 4 = UNIT4 5 = ALL l10sysPlatformAlarm2Unit l10sysPlatformTBL.13 INTEGER 1 = UNIT1 2 = UNIT2 3 = UNIT3 4 = UNIT4 5 = ALL l10sysPlatformAlarm3Unit l10sysPlatformTBL.14 INTEGER...
  • Page 65 3. SNMP ● l10systemTBL(2) group LV 58SER01A (SDI INPUT) SYNTAX ACCESS VALUE/RANGE l10sysUnitSdiTBL l10systemTBL.2 Aggregate l10sysUnitSdiLinkFormat l10sysUnitSdiTBL.1 INTEGER 1 = SINGLE 2 = DUAL 3 = 2K l10sysUnitSdiIPSF l10sysUnitSdiTBL.2 INTEGER 1 = INTERLACE 2 = SEG.FRAM l10sysUnitSdiDualTBL l10sysUnitSdiTBL.3 Aggregate l10sysUnitSdiDualSystem l10sysUnitSdiDualTBL.1 INTEGER 1 = GBR-444...
  • Page 66 3. SNMP SYNTAX ACCESS VALUE/RANGE l10sysUnitSdiErrAudTBL l10sysUnitSdiTBL.9 Aggregate l10sysUnitSdiErrAudioBch l10sysUnitSdiErrAudTBL.1 INTEGER 1 = ON 2 = OFF l10sysUnitSdiErrAudioDbn l10sysUnitSdiErrAudTBL.2 INTEGER 1 = ON 2 = OFF l10sysUnitSdiErrAudioParity l10sysUnitSdiErrAudTBL.3 INTEGER 1 = ON 2 = OFF l10sysUnitSdiErrAudioInhibit l10sysUnitSdiErrAudTBL.4 INTEGER 1 = ON 2 = OFF l10sysUnitSdiErrGamutTBL l10sysUnitSdiTBL.10...
  • Page 67 3. SNMP ● l10systemTBL(2) group LV 58SER40A (DIGITAL AUDIO) SYNTAX ACCESS VALUE/RANGE l10sysUnitAudioTBL l10systemTBL.3 Aggregate l10sysUnitAudioExtBnc l10sysUnitAudioTBL.1 INTEGER 1 = INPUT 2 = OUTPUT l10sysUnitAudioErrHdTBL l10sysUnitAudioTBL.2 Aggregate l10sysUnitAudioErrorLevelOver l10sysUnitAudioErrHdTBL.1 INTEGER 1 = ON 2 = OFF l10sysUnitAudioErrorClip l10sysUnitAudioErrHdTBL.2 INTEGER 1 = ON 2 = OFF l10sysUnitAudioErrorClipDuration l10sysUnitAudioErrHdTBL.3...
  • Page 68 3. SNMP ● l10systemTBL(2) group LV 58SER02 (EYE PATTERN unit) SYNTAX ACCESS VALUE/RANGE l10sysUnitEyeTBL l10systemTBL.4 Aggregate l10sysUnitEyeErrHdTBL l10sysUnitEyeTBL.1 Aggregate l10sysUnitEyeErrHdAmp l10sysUnitEyeErrHdTBL.1 INTEGER 1 = ON 2 = OFF l10sysUnitEyeErrHdAmpUpper l10sysUnitEyeErrHdTBL.2 INTEGER 80 to 140 l10sysUnitEyeErrHdAmpLower l10sysUnitEyeErrHdTBL.3 INTEGER 40 to 100 l10sysUnitEyeErrHdRise l10sysUnitEyeErrHdTBL.4 INTEGER...
  • Page 69 3. SNMP ● l10systemTBL(2) Group LV 58SER04 (MPEG DECODER) SYNTAX ACCESS VALUE/RANGE l10sysUnitMpegTBL l10systemTBL.11 Aggregate l10sysUnitMpegSemiAutoSearch l10sysUnitMpegTBL.1 INTEGER 1 = ON 2 = OFF l10sysUnitMpegErrSyncByte l10sysUnitMpegTBL.2 INTEGER 1 = ON 2 = OFF l10sysUnitMpegErrContinuity l10sysUnitMpegTBL.3 INTEGER 1 = ON 2 = OFF l10sysUnitMpegErrPat l10sysUnitMpegTBL.4 INTEGER...
  • Page 70 3. SNMP SYNTAX ACCESS VALUE/RANGE l10wfmScaleTBL l10wfmTBL.3 Aggregate l10wfmScaleUnit l10wfmScaleTBL.1 INTEGER 1 = HDV-SDP 2 = HDV-SDV 3 = HDP-SDP l10wfmScaleColor75per l10wfmScaleTBL.2 INTEGER 1 = ON 2 = OFF l10wfmScaleColor l10wfmScaleTBL.3 INTEGER 1 = WHITE 2 = YELLOW 3 = CYAN 4 = GREEN 5 = MAGENTA 6 = RED...
  • Page 71 3. SNMP SYNTAX ACCESS VALUE/RANGE l10wfmLineNumber l10wfmLineSelTBL.3 INTEGER 1 to 1125 l10wfmFilterTBL l10wfmTBL.7 Aggregate l10wfmFilterNormal l10wfmFilterTBL.1 INTEGER 1 = FLAT 2 = LOWPASS l10wfmFilterComposite l10wfmFilterTBL.2 INTEGER 1 = FLAT 2 = FLAT-LUM 3 = FLAT-CHROMA l10wfmBlankingTBL l10wfmTBL.8 Aggregate l10wfmBlankingNormal l10wfmBlankingTBL.1 INTEGER 1 = REMOVE 2 = H-VIEW...
  • Page 72 3. SNMP SYNTAX ACCESS VALUE/RANGE l10vecGainTBL l10vectorTBL.3 Aggregate l10vecGainVar l10vecGainTBL.1 INTEGER 1 = CAL 2 = VAR l10vecGainVal l10vecGainTBL.2 OctetStrin 0.200 to 2.000 l10vecGainMag l10vecGainTBL.3 INTEGER 1 = X1 2 = X5 3 = IQ l10vecLineSelTBL l10vectorTBL.4 Aggregate l10vecLineSelect l10vecLineSelTBL.1 INTEGER 1 = ON 2 = OFF...
  • Page 73 3. SNMP ● l10pictureTBL(5) group * Valid when MODE of DISPLAY selected is PICTURE. SYNTAX ACCESS VALUE/RANGE l10picBright l10pictureTBL.1 INTEGER -30 to 30 l10picContrast l10pictureTBL.2 OctetString 0.70 to 1.30 l10picGainTBL l10pictureTBL.3 Aggregate l10picGainRed l10picGainTBL.1 OctetString 0.70 to 1.30 l10picGainGreen l10picGainTBL.2 OctetString 0.70 to 1.30 l10picGainBlue...
  • Page 74 3. SNMP SYNTAX ACCESS VALUE/RANGE l10picGamutTBL l10pictureTBL.9 Aggregate l10picGamutError l10picGamutTBL.1 INTEGER 1 = ON 2 = OFF l10picGamutPattern l10picGamutTBL.2 INTEGER 1 = WHITE 2 = RED 3 = MESH l10picDispTBL l10pictureTBL.10 Aggregate l10picDispAfd l10picDispTBL.1 INTEGER 1 = ON 2 = OFF ●...
  • Page 75 3. SNMP SYNTAX ACCESS VALUE/RANGE l10audLissajouForm l10audLissajouTBL.3 INTEGER 1 = X-Y 2 = MATRIX l10audLissajouAutoGain l10audLissajouTBL.4 INTEGER 1 = ON 2 = OFF l10audLissajouMapTBL l10audLissajouTBL.5 Aggregate l10audlissajouMapSingleL l10audLissajouMapTBL.1 INTEGER 1 = CH1 2 = CH2 3 = CH3 4 = CH4 5 = CH5 6 = CH6 7 = CH7...
  • Page 76 3. SNMP SYNTAX ACCESS VALUE/RANGE l10audlissajouMapMultiR1 l10audLissajouMapTBL.4 INTEGER 1 = CH1 2 = CH2 3 = CH3 4 = CH4 5 = CH5 6 = CH6 7 = CH7 8 = CH8 9 = CH9 10 = CH10 11 = CH11 12 = CH12 13 = CH13 14 = CH14...
  • Page 77 3. SNMP SYNTAX ACCESS VALUE/RANGE l10audlissajouMapMultiL3 l10audLissajouMapTBL.7 INTEGER 1 = CH1 2 = CH2 3 = CH3 4 = CH4 5 = CH5 6 = CH6 7 = CH7 8 = CH8 9 = CH9 10 = CH10 11 = CH11 12 = CH12 13 = CH13 14 = CH14...
  • Page 78 3. SNMP SYNTAX ACCESS VALUE/RANGE l10audlissajouMapMultiR4 l10audLissajouMapTBL.10 INTEGER 1 = CH1 2 = CH2 3 = CH3 4 = CH4 5 = CH5 6 = CH6 7 = CH7 8 = CH8 9 = CH9 10 = CH10 11 = CH11 12 = CH12 13 = CH13 14 = CH14...
  • Page 79 3. SNMP SYNTAX ACCESS VALUE/RANGE l10audlissajouMapMultiL6 l10audLissajouMapTBL.13 INTEGER 1 = CH1 2 = CH2 3 = CH3 4 = CH4 5 = CH5 6 = CH6 7 = CH7 8 = CH8 9 = CH9 10 = CH10 11 = CH11 12 = CH12 13 = CH13 14 = CH14...
  • Page 80 3. SNMP SYNTAX ACCESS VALUE/RANGE l10audlissajouMapMultiR7 l10audLissajouMapTBL.16 INTEGER 1 = CH1 2 = CH2 3 = CH3 4 = CH4 5 = CH5 6 = CH6 7 = CH7 8 = CH8 9 = CH9 10 = CH10 11 = CH11 12 = CH12 13 = CH13 14 = CH14...
  • Page 81 3. SNMP SYNTAX ACCESS VALUE/RANGE l10audSImageMapTBL l10audSImageTBL.4 Aggregate l10audSImageMapL l10audSImageMapTBL.1 INTEGER 1 = CH1 2 = CH2 3 = CH3 4 = CH4 5 = CH5 6 = CH6 7 = CH7 8 = CH8 9 = CH9 10 = CH10 11 = CH11 12 = CH12 13 = CH13...
  • Page 82 3. SNMP SYNTAX ACCESS VALUE/RANGE l10audSImageMapRs l10audSImageMapTBL.4 INTEGER 1 = CH1 2 = CH2 3 = CH3 4 = CH4 5 = CH5 6 = CH6 7 = CH7 8 = CH8 9 = CH9 10 = CH10 11 = CH11 12 = CH12 13 = CH13 14 = CH14...
  • Page 83 3. SNMP SYNTAX ACCESS VALUE/RANGE l10audSImageMapLl l10audSImageMapTBL.7 INTEGER 1 = CH1 2 = CH2 3 = CH3 4 = CH4 5 = CH5 6 = CH6 7 = CH7 8 = CH8 9 = CH9 10 = CH10 11 = CH11 12 = CH12 13 = CH13 14 = CH14...
  • Page 84 3. SNMP SYNTAX ACCESS VALUE/RANGE l10audStatusUserBit l10audStatusTBL.3 INTEGER 1 = CH1 2 = CH2 3 = CH3 4 = CH4 5 = CH5 6 = CH6 7 = CH7 8 = CH8 9 = CH9 10 = CH10 11 = CH11 12 = CH12 13 = CH13 14 = CH14...
  • Page 85 3. SNMP SYNTAX ACCESS VALUE/RANGE l10audDolbyEMetaPrm l10audDolbyTBL.5 INTEGER 1 = PRM1 2 = PRM2 3 = PRM3 4 = PRM4 5 = PRM5 6 = PRM6 7 = PRM7 8 = PRM8 l10audDolbyDListening l10audDolbyTBL.6 INTEGER 1 = FULL 2 = EX 3 = 3stereo 4 = PHANTOM 5 = STEREO...
  • Page 86 3. SNMP ● l10statusTBL(7) group * Valid when MODE of DISPLAY selected is STATUS. SYNTAX ACCESS VALUE/RANGE l10staCounter l10statusTBL.1 INTEGER 1 = SEC 2 = FIELD 3 = PER-FIELD l10staReset l10statusTBL.2 INTEGER R/WO 1 = STATUS RESET l10staLogTBL l10statusTBL.3 Aggregate l10staLog l10staLogTBL.1 INTEGER...
  • Page 87 3. SNMP SYNTAX ACCESS VALUE/RANGE l10eyeJitterGain l10eyeJitterTBL.3 INTEGER 1 = X1 2 = X2 3 = X8 l10eyeJitterSweep l10eyeJitterTBL.4 INTEGER 1 = 1H 2 = 2H 3 = 1V 4 = 2V l10eyeJitterFilter l10eyeJitterTBL.5 INTEGER 1 = 100kHz 2 = 1kHz 3 = 100Hz 4 = 10Hz 5 = Timing...
  • Page 88: Enterprise Trap

    This section describes the enterprise traps of the LV 5800. The LV 5800 will not be able to perform trap processing on all events when events occur consecutively at a rate of one event per second or more. The trap buffer can store up to 1000 events.
  • Page 89: Specific Trap

    3. SNMP 3.5.2 Specific Trap Description Specific Trap Type Fan stop detection NO SIGNAL Line number error detection CRC error detection (LUMA) CRC error detection (CHROMA) Checksum error detection BCH error detection EDH error detection Reserved area error detection Parity error detection TRS error detection (POS) TRS error detection (CODE) Freeze error detection...
  • Page 90: Variable Binding List

    3. SNMP 3.5.3 Variable Binding List ● index 1 OID: leader(20111).lv5800(10).lv5800ST1(1).trapTBL(9).trapStrTBL(1).1.0 Syntax: Counter Range: 1 to 4294967295 (overflow occurs if this range is exceeded) Description: The total number of enterprise traps sent after starting up. ● index 2 OID: leader(20111).lv5800(10).lv5800ST1(1).trapTBL(9).trapStrTBL(1).2.0...
  • Page 91 3. SNMP List of format information List of error information for TRAP for TRAP Syntax Format Syntax Description 1080i/60 1080i/60 CRC_Y_ERR CRC error detection (LUMA) 1080sF/30 1080sF/30 CRC_C_ERR CRC error detection (CHROMA) 1080i/59.94 1080i/59.94 EDH_ERR EDH error detection 1080sF/29.97 1080sF/29.97 TRS_P_ERR TRS error detection (POS) 1080i/50...
  • Page 92: Firmware Revision History

    ・ Telnet and SNMP support were added for the new features of the LV 58SER01(A), LV 58SER03, and LV 58SER04. ● Ver. 3.7 ・ Telnet and SNMP support were added for the new features of the LV 5800 and for the features of the LV 58SER04 and LV 58SER40A. ● Ver. 3.4 ・...
  • Page 93 LEADER ELECTRONICS CORP. 2-6-33 Tsunashima-Higashi, Kohoku-ku, Yokohama 223-8505, Japan PHONE:81-45-541-2123 FAX:81-45-541-2823 http://www.leader.co.jp Nov. 20, 2009 Ver.10 (FW Ver.6.2)

Table of Contents