3-3-3. Prompter Level 1/2 Adjustment

Measures : SD waveform monitor (NTSC or PAL)
SD signal generator (NTSC or PAL)
Preparation
Connect the SD signal generator (for NTSC : SMPTE
color bar/for PAL : EBU color bar) to the PROMPTER IN
connector on the HDCU rear panel.
Adjustment Procedure
1. PROMPTER 1 level adjustment
Measuring point : PROMPTER 1 connector/CAMERA
side
Adjusting point : 1RV301 (G-1)/DTX-5 board
A = 140 ± 1 IRE
Specifications :
(terminated at 75 Z) (for NTSC)
A = 1000 ± 7 mV p-p
(terminated at 75 Z) (for PAL)
2. PROMPTER 2 level adjustment
Measuring point : PROMPTER 2 connector/CAMERA
side
Adjusting point : 1RV701 (G-2)/DTX-5 board
A = 140 ± 1 IRE
Specifications :
(terminated at 75 Z) (for NTSC)
A = 1000 ± 7 mV p-p
(terminated at 75 Z) (for PAL)
[for NTSC]
A
1
1
MM/HDCU1000 Series
[for PAL]
A
1
TP251
DTX-5 board (A side)
3-4. Video Signal System Adjustment
(Front board)

3-4-1. SD-SDI Input VCO Free-run Adjustment

Measure : Frequency counter, Oscilloscope
Note
After replacing IC251 on the DTX-5 board only, perform
this adjustment.
Preparation
. To be extended : DTX-5 board (front side)
. For the HDCU1000, disconnect the cables connected to
the HD SDI1 connector on the HDCU rear panel, and the
SD SDI1 connector on the HDCU rear panel
. For the HDCU1500, disconnect the cable connected to
the RET1 connector on the HDCU rear panel.
. Connect the measure as shown in the following figure.
. After turning on the power, wait for 10 minutes at least
and start adjustment.
CH2
Probe
IN
Oscilloscope
Adjustment Procedure
1. Measuring point : TP251 (E-4)/DTX-5 board
Adjusting point : 1RV251 (F-4)/DTX-5 board
27.0 ± 0.2 MHz
Specifications :
n
After finishing the adjustment and waiting for 10 minutes
at least, confirm that each specification is met.
If the specifications are not met, perform the adjustment
again.
Setting after Adjustment
After finishing the adjustment, reconnect the disconnected
cables.
CH2
IN
OUT
Frequency
counter