Page 1
SA58605 Dual operational amplifier and 2.5 V shunt regulator Product data Supersedes data of 2002 Mar 25 INTEGRATED CIRCUITS 2003 Nov 12...
Page 2
Dual operational amplifier and 2.5 V shunt regulator DESCRIPTION The SA58605 incorporates two op amps and 2.5 V shunt regulator in an unique circuit configuration. The output of the device is inverted when the inverting inputs of either or both op amps exceed the internally set reference voltages at their non-inverting inputs.
Philips Semiconductors Dual operational amplifier and 2.5 V shunt regulator ORDERING INFORMATION PACKAGE TYPE NUMBER TYPE NUMBER NAME DESCRIPTION SOT23-5, SA58605D Plastic small outline package; 5 leads; body width 1.6 mm SOT25, SO5 Part number marking The package is marked with a four letter code. The first three letters designate the product.
Philips Semiconductors Dual operational amplifier and 2.5 V shunt regulator MAXIMUM RATINGS SYMBOL Supply voltage Ambient operating temperature Storage temperature Power dissipation ELECTRICAL CHARACTERISTICS = 25 C, V = 5 V (see Figure 6 “Test circuit”, and Table 1 “Parameter test circuit 1 and power supply settings”), unless otherwise specified.
Philips Semiconductors Dual operational amplifier and 2.5 V shunt regulator TEST CIRCUITS 0.22 F 1.5 k 3.9 k 680 k 1.5 V 47 F Table 1. Parameter test circuit 1 switch and power supply settings SYMBOL PARAMETER Power supply current...
Figure 7 shows the schematic for a Universal Converter/Charger circuit in which the SA58605 Amp “A” is used to monitor the B+ level of the converter/charger. Amp “B” input is pulled to ground through a resistor and will remain there. The input to the Amp “A” is maintained at 0.5...
Philips Semiconductors Dual operational amplifier and 2.5 V shunt regulator PACKING METHOD GUARD TAPE BAND BARCODE LABEL 2003 Nov 12 REEL ASSEMBLY Figure 8. Tape and reel packing method. Product data SA58605 TAPE DETAIL COVER TAPE CARRIER TAPE SL01305...
Page 8
Philips Semiconductors Product data Dual operational amplifier and 2.5 V shunt regulator SA58605 Plastic small outline package; 5 leads; body width 1.6 mm SOP003 2003 Nov 12...
Life support — These products are not designed for use in life support appliances, devices, or systems where malfunction of these products can reasonably be expected to result in personal injury. Philips Semiconductors customers using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Philips Semiconductors for any damages resulting from such application.