CHAPTER 2
SPECIFIC INFORMATIONS
SAFETY INSTRUCTIONS
SERVICE MODE
ADJUSTING ITEMS AND DATAS IN THE SERVICE MODE:
Item
Name of adjustment
RCUT
R CUTOFF (B/W)
GCUT
G CUTOFF (B/W)
BCUT
B CUTOFF (B/W)
GDRV
G DRIVE
BDRV
B DRIVE
CNTX
SUB CONTRAST MAX (4:3 MODE)
BRTC
SUB BRIGHT CEN
COLC
SUB COLOR CEN NTSC
TNTC
SUB TINT CEN
COLP
SUB COLOR CEN PAL
COLS
SUB COLOR CEN SECAM
SCNT
SUB CONTRAST
VOLS
VOL SCART
FVOL
FM VOL PRE SCALE
NVOL
NICAM VOL PRE SCALE
NICL
NICAM THRESHOLD LEVEL
NICH
NICAM THRESHOLD LEVEL
IDL
IGR THRESHOLD LEVEL
DESIGN MODE
ADJUSTING ITEMS AND DATAS IN THE DESIGN MODE:
Item
OPT0
OPTION 0
OPT1
OPTION 1
OPT2
OPTION 2
OPT3
OPTION 3
OPT4
OPTION 4
SETTING & ADJUSTING DATA
HIGH VOLTAGE AT ZERO BEAM:
MAX HIGH VOLTAGE:
AC VOLTAGE
Table-1
Data
Preset
←
40H
←
40H
←
40H
←
35H
←
35H
←
7FH
←
80H
←
45H
←
1FH
←
01H
←
45H
←
0CH
←
75H
←
15H
←
3CH
←
03H
←
0AH
←
90H
Table-2
Name of adjustment
Preset Data
Table-3
34"
32.8 kV
(A)
33.4 kV
(B)
110~240 V
(C)
Item
Name of adjustment
IDH
IGR THRESHOLD LEVEL
EVOL
EXT PRE. VOLUME
HPOS
50Hz H-POSITION
VPOS
V-POSITION HEIGHT
HIT
HEIGHT
VLIN
V-LINEARITY
VSC
V-S CORRECTION
VPS
V-SHIFT
VCP
V-COMPENSATION
WID
PICTURE WIDTH
PARA
E-W PARABOLA
CNR
E-W CORNER
TRAP
TRAPEZIUM
HCP
H-COMPENSATION
VFC
V-F CORRECTION
SRY
SECAM R-Y
SBY
SECAM-B-Y
Data
00H
00H
42H
42H
04H
04H
DFH
DFH
63H
63H
– 18 –
Data
Preset
←
A0H
←
02H
2CH
2EH
AEH
B5H
61H
47H
←
13H
15H
16H
06H
0CH
←
05H
1EH
25H
1CH
18H
09H
0AH
1AH
28H
←
01H
←
0FH
07H
07H
04H
04H
Remarks