Electrical Connection - Bosch Tronic 1000T Installation And Operating Instructions Manual

Table of Contents

Advertisement

14 | Electrical connection

NOTICE:
This drain pipe must fall continuously, shall
be left open to the atmosphere, and shall be
in a frost free environment
WARNING:
Relief valve easing gear should be checked
and operated AT LEAST ONCE EVERY SIX
MONTHS.
If water does not discharge freely when the
lever is operated, the valve should be
checked by an authorised agent.
WARNING:
The relief valve and relief valve drain pipe
must not be sealed or blocked. Small
amounts of water may leak from the relief
valve during heating cycles.
WARNING:
Relief valves should be replaced at intervals
not exceeding 5years, or more frequently in
areas where water quality is poor
WARNING:
The function of the PTR valve is to discharge
high temperature water under certain
conditions. Therefore it is strongly
recommended that the pipe work connected
to the PTR valve is able to withstand water
temperatures exceeding 99 °C. Failure to
follow this recommendation may result in a
dangerous situation
Connect the outlet of the PTR valve to a suitable open drain so
that the discharge water cannot contact any electrical parts,
persons or animals, and to eliminate any other possible risks.
The drain line from the PTR valve must comply with the
requirements of AS/NZS 3500.4.
Always use a PTR valve of the same rated pressure and
temperature as the PTR Valve supplied with the unit.
6 720 821 421 (2017/04)
6
Electrical connection
Connection to this storage water heater must
be from a single phase 240V 50Hz supply
and comply with AS/NZS 3000 Wiring Rules.
Installations in New Zealand must comply
with the New Zealand Building Code.
A means for disconnection must be
incorporated in the fixed wiring in
accordance with the wiring rules
The appliance must only be installed by an
authorised person.
DANGER: Electric shock!
▶ Isolate the appliance from the power
supply using the circuit breaker isolation
switch or another electrical protection
device before carrying out any work on
electrical parts.
▶ The electrical connection is made to the water heater at the
terminal block located under the terminal box cover
▶ To remove this cover, simply remove two screws on the
outer casing and lift off the lid
The electrical enclosure is tested and
approved to IP X4.
The following must be observed during installation:
▶ Check all connections as wires may work loose in transit
▶ Check the thermostat setting is 65°C, which is the factory
setting, and adjust if required.
▶ Ensure the circuit incorporates an isolation switch or circuit
breaker.
▶ The household wiring to the water heater must be rated to
withstand the electric element load.
Tronic 1000 T

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents