GE C30 Instruction Manual page 355

Controller system ur series
Hide thumbs Also See for C30:
Table of Contents

Advertisement

APPENDIX B
Table B–10: MODBUS MEMORY MAP (Sheet 27 of 48)
ADDR
REGISTER NAME
9995
Teleprotection Terminal 2 ID
9996
Reserved (10 items)
9A00
Teleprotection Input 1-n Default States (16 items)
9A10
Teleprotection Input 2-n Default States (16 items)
9A20
Teleprotection Output 1-n Operand (16 items)
9A40
Teleprotection Output 2-n Operand (16 items)
Teleprotection Channel Tests (Read Only)
9AA0
Teleprotection Channel 1 Status
9AA1
Teleprotection Channel 1 Number of Lost Packets
9AA2
Teleprotection Channel 2 Status
9AA3
Teleprotection Channel 2 Number of Lost Packets
9AA4
Teleprotection Network Status
9AAF
Teleprotection Channel 1 Input States
9AB0
Teleprotection Channel 2 Input States
9AC0
Teleprotection Input 1 States, 1 per register (16 items)
9AD0
Teleprotection Input 2 States, 1 per register (16 items)
Selector Switch Actual Values (Read Only)
A210
Selector Switch 1 Position
A211
Selector Switch 2 Position
Selector Switch Settings (Read/Write) (2 modules)
A280
Selector 1 Function
A281
Selector 1 Range
A282
Selector 1 Timeout
A283
Selector 1 Step Up
A285
Selector 1 Step Mode
A286
Selector 1 Acknowledge
A288
Selector 1 Bit0
A28A
Selector 1 Bit1
A28C
Selector 1 Bit2
A28E
Selector 1 Bit Mode
A28F
Selector 1 Bit Acknowledge
A291
Selector 1 Power Up Mode
A292
Selector 1 Target
A293
Selector 1 Events
A294
Reserved (10 items)
A29E
...Repeated for Selector 2
Digital Counter (Read/Write Setting) (8 modules)
A300
Digital Counter 1 Function
A301
Digital Counter 1 Name
A307
Digital Counter 1 Units
A30A
Digital Counter 1 Block
A30C
Digital Counter 1 Up
A30E
Digital Counter 1 Down
A311
Digital Counter 1 Preset
A313
Digital Counter 1 Compare
A315
Digital Counter 1 Reset
A317
Digital Counter 1 Freeze/Reset
A319
Digital Counter 1 Freeze/Count
A31B
Digital Counter 1 Set To Preset
A31D
Reserved (11 items)
A328
...Repeated for Digital Counter 2
A350
...Repeated for Digital Counter 3
A378
...Repeated for Digital Counter 4
GE Multilin
RANGE
0 to 255
0 to 1
0 to 3
0 to 3
0 to 4294967295
0 to 4294967295
0 to 2
0 to 65535
0 to 2
0 to 65535
0 to 2
0 to 1
0 to 1
0 to 1
0 to 1
1 to 7
1 to 7
0 to 1
1 to 7
3 to 60
0 to 4294967295
0 to 1
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 1
0 to 4294967295
0 to 2
0 to 2
0 to 1
---
0 to 1
---
---
0 to 4294967295
0 to 4294967295
0 to 4294967295
–2147483647 to
2147483647
–2147483647 to
2147483647
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
---
C30 Controller System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
1
F001
---
1
F001
---
1
F086
---
1
F086
---
1
F300
---
1
F300
---
1
F134
---
1
F001
---
1
F134
---
1
F001
---
1
F134
---
1
F500
---
1
F500
---
1
F108
---
1
F108
---
1
F001
---
1
F001
---
1
F102
---
1
F001
s
0.1
F001
---
1
F300
---
1
F083
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F083
---
1
F300
---
1
F084
---
1
F109
---
1
F102
---
1
F001
---
1
F102
---
---
F205
---
---
F206
---
1
F300
---
1
F300
---
1
F300
---
1
F004
---
1
F004
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
---
F001
DEFAULT
0
0
0 (Off)
0 (Off)
0
0
1 (OK)
0
2 (n/a)
0
B
2 (n/a)
0
0
0 (Off)
0 (Off)
0
1
0 (Disabled)
7
50
0
0 (Time-out)
0
0
0
0
0 (Time-out)
0
0 (Restore)
0 (Self-reset)
0 (Disabled)
0
0 (Disabled)
"Counter 1"
(none)
0
0
0
0
0
0
0
0
0
0
B-35

Advertisement

Table of Contents
loading

Table of Contents