Camera-mounted eng/efp fiber optic transceiver system for jvc gy-hm790hd camcorder (86 pages)
Summary of Contents for Telecast CopperHead 3400
Page 1
A BELDEN Brand ™ CopperHead 3400 Series 3000 Camera-Mountable ENG/EFP Fiber Optic Transceiver System User Manual PRELIMINARY Telecast Fiber Systems, Inc. 102 Grove Street Worcester, MA 01605 Tel: 508-754-4858 Fax: 508-752-1520 www.telecast-fiber.com...
CopperHead 3400 Camera Unit Front Side ......................23 CopperHead 3400 Camera Unit Back Side – Identifying Controls and Connectors..........24 3.2. CopperHead 3400 Base Station......................27 Telecast Fiber Systems – CopperHead 3400 Transceiver System User Guide – Preliminary Version Page 1...
Page 4
CHAPTER 5. CONNECTION OF THE COPPERHEAD 3400 TRANSCEIVER SYSTEM..45 5.1. Section - Connections between the Copperhead 3400 Base Station and the Camera Unit ..... 45 Tactical Fiber between the Base Station and Camera Unit ..................46 SMPTE Hybrid Fiber between the Base Station (powered) and Camera Unit............47 SMPTE Hybrid Fiber between Base Station and Camera Unit (Infrastructure Wiring)...........
Page 5
RTS Intercom – Base Station 3 Pin XLR Connector Wiring..................83 Base Station 12VDC Terminal Block Wiring......................83 1.2. CopperHead 3400 Camera Unit Multi-Pin Connectors ................. 84 Telecast Fiber Systems – CopperHead 3400 Transceiver System User Guide – Preliminary Version Page 3...
Page 6
CopperHead 3400 Base Station 25-Pin Audio Input Cable..................93 CopperHead 3400 Base Station 25-Pin Audio Output Cable .................. 94 APPENDIX 5. SPECIFICATION.......................95 APPENDIX 6. COPPERHEAD 3400 TRANSCEIVER SYSTEM OVERVIEW......97 Telecast Fiber Systems – CopperHead 3400 Transceiver System User Guide – Preliminary Version Page 4...
FIGURE 17 - MOUNTING THE COPPERHEAD 3400 CAMERA UNIT TO THE CAMERA ..........40 FIGURE 18 - MOUNTING THE POWER WAFER UNIT TO THE COPPERHEAD 3400 CAMERA UNIT....... 41 FIGURE 19 - MOUNTING THE POWERPLUS UNIT TO THE COPPERHEAD 3400 CAMERA UNIT ........42 FIGURE 20 - COPPERHEAD 3400 BASE STATION WITH REAR MOUNTED FIBER CONNECTOR ........
TABLE 18 - CAMERA UNIT AUDIO 1 & 2 CONNECTOR WIRING................... 85 About this User Guide This CopperHead 3400 Fiber Optic Transceiver System can be delivered in a number of configurations depending on the Power and Battery Mount options selected. This user guide is designed to cover all of the various options and so not every page in this guide will apply to your specific system.
A claim of defect in materials or workmanship in any Product shall be allowed only when it is submitted in writing to Telecast Fiber Systems, Inc. within seven days after discovery of the defect, and in any event within the Warranty Period.
Power Fuses The CopperHead 3400 Base Station with internal power is equipped with Dual Cartridge fuses located next to the AC Power receptacle at the left rear of the unit. Refer to Appendix 5 for specific location information.
Suggestions for these cables are discussed later in this document. Leave the protective caps on the optical connectors whenever the fiber is disconnected. Telecast Fiber Systems – CopperHead 3400 Transceiver System User Guide – Preliminary Version Page 9...
A Belden Brand 1.4. Product Returns In the unlikely event of damage to your CopperHead 3400 Fiber Optic Transceiver System during shipping or delivery please note the damage with the delivery or shipping service and document the packaging and product where you see damage. If any component does not work correctly out of the box please contact Telecast Fiber Systems service at (508) 754-4858.
1) Fiber Optic Cable Concepts 2) CopperHead 3400 Transceiver System concepts 3) Signal paths in the CopperHead 3400 Transceiver System 4) CopperHead 3400 Transceiver System Components Telecast Fiber Systems – CopperHead 3400 Transceiver System User Guide – Preliminary Version Page 11...
A Belden Brand 2.1. Fiber Cable Concepts Fiber Optics and Fiber Optic Cable are the core technologies at the heart of the Telecast Fiber Systems CopperHead 3400 Transceiver System. The ability to multiplex and de-multiplex a variety of video, audio and data signals so that they can be carried over a thin strand of Fiber Optic cable for long distances enables the CopperHead System.
Depending on the type of Fiber Optic Cable used, different Connector types can be configured. The following table summarizes the various types of connectors typically used in a CopperHead 3400 Transceiver System configuration and the allowed Fiber Optic Cable usage. Each connector type is illustrated below.
Triax or multi-core cable is sent, bi-directionally, over a single lightweight fiber over distances as long as 5 km or more. The CopperHead 3400 is specifically designed to support the use of 3D or Dual-Link camera setups.
2.3. Signal paths in the CopperHead 3400 Transceiver System The CopperHead 3400 Transceiver System utilizes an optical fiber link between the Base Station and the Camera Unit to carry all of the required signals necessary for operation of the camera and associated production equipment.
The actual appearance of your CopperHead 3400 Camera Unit will vary depending on the battery mount and fiber cable connection options specified at the time of purchase. Telecast Fiber Systems – CopperHead 3400 Transceiver System User Guide – Preliminary Version...
Figure 7 - CopperHead 3400 Base Station Front Panel Figure 8 - CopperHead 3400 Base Station Connector or Back Panel The actual appearance of your CopperHead 3400 Base Station will vary depending on the fiber cable connection and power options specified at the time of purchase.
A Belden Brand CopperHead 3400 Transceiver System Additional Components In addition to the CopperHead 3400 Camera Unit and Base Station the system consists of: 1. External Power Supply or Power Cord for the Base Station (depending the unit configuration) 2. Cable Sets as required by your camera and remote controller types to connect the CopperHead Camera Unit to the camera, and to connect the Base Station to the optional remote controller 3.
3400 Transceiver System. Physical installation of the system and system connections and practical operation are covered in following chapters. For an overall view of component location please see the CopperHead 3400 Transceiver System overall diagrams in Appendix 6. These diagrams can be folded out from the back of this User’s Guide.
5) Audio 1 & 2 Input (Line Level) - (to Base Station) Typically audio program from camera line outputs 6) Audio 3 & 4 Output (from Base Station) Typically return audio from the Base Station Telecast Fiber Systems – CopperHead 3400 Transceiver System User Guide – Preliminary Version Page 20...
Page 23
(see Appendix 1 for wiring information) 8) Production DB15HD Connector for Tally, Intercom Trigger, Serial Communication (RS232/422/485) l (see Appendix 1 for wiring information) Telecast Fiber Systems – CopperHead 3400 Transceiver System User Guide – Preliminary Version Page 21...
Page 24
C) MX Expanded Beam (unpowered) Area F – Battery Mount The CopperHead 3400 Camera Unit is shipped with a variety of Battery Mount to camera types. The Anton Bauer mount and the Sony V-mount are the most common. PAG and other battery mount systems are available by special order.
C) Signal/Data LED Activity Indicators See Page 25 D) Digital Status Display & Power Switch See Page 26 Figure 10 - CopperHead 3400 Camera Unit Front Side Telecast Fiber Systems – CopperHead 3400 Transceiver System User Guide – Preliminary Version Page 23...
Area B – Camera Mounting Plate The CopperHead 3400 Camera Unit is shipped with a variety of Battery Mount to camera types. The Anton Bauer mount and the Sony V-mount are the most common. PAG and other battery mount systems are available by special order.
Page 27
A Belden Brand Area C – Signal/Data Indicators The CopperHead 3400 Camera Unit Indicator Panel has a series of LED displays that monitor the various signal paths between the Camera Unit and the Base Station. For signals remain constant such as time code and video the LED remains on as a steady green.
Page 28
Base Station this enables or disables camera power. When used with the low voltage Base Station this turns camera power on and off Telecast Fiber Systems – CopperHead 3400 Transceiver System User Guide – Preliminary Version Page 26...
A Belden Brand 3.2. CopperHead 3400 Base Station The CopperHead 3400 Base Station is available with a number of options. The unit is ordered with a specified Power Module, Audio/Intercom Module and Fiber Connector. For an overall view of component location please see the overall diagrams in Appendix 6.
Page 30
Monitors the time code signal generated by the Camera coming to the Base Station and the Base or House time code from the Base Station to the Camera Unit Telecast Fiber Systems – CopperHead 3400 Transceiver System User Guide – Preliminary Version Page 28...
Page 31
High voltage will not be applied to the camera until the open condition is corrected. CABLE SHORT - indicates that the high voltage cable connected is shorted. Telecast Fiber Systems – CopperHead 3400 Transceiver System User Guide – Preliminary Version Page 29...
Page 32
Red if there is a Base Station error. Refer to the Base Station DIAG for details on the error. Orange if there is a camera error. Refer to CAM DIAG for details for the error. Telecast Fiber Systems – CopperHead 3400 Transceiver System User Guide – Preliminary Version Page 30...
Area A – Power & Fiber Connectors (Power Module) The CopperHead 3400 Base Station can be configured with one of five different Power Module Options. The connection and practical use of each of these options is covered in Chapter 5. Multi-pin connector wiring suggestions are covered in Appendix 1.1.
Internal Power with STs and Molex Connectors 4) STs Connector with Molex for Camera power Internal Power with SMPTE 304M Connector 4) SMPTE 304M Connector Telecast Fiber Systems – CopperHead 3400 Transceiver System User Guide – Preliminary Version Page 32...
Page 35
Area D – Audio/Intercom Connectors The CopperHead 3400 Base Station can be configured with one of three different Intercom Options. The connection and practical use of each of these options is covered in Chapter 6 – Page 67. Multi-pin connector...
A Belden Brand 3.3. Additional Copperhead 3400 Transceiver System Items Your Copperhead 3400 Transceiver System may consist of one or more of the following items. 1. Portable fiber reel with fiber per your purchase order 2. Optional Universal Camera Control Unit (please refer to the User’s guide supplied with this product) 3.
The Power Wafer replaces the local camera battery and any local AC power supply adaptor. The Power Wafer gets its power from the use Hybrid fiber cable and the CopperHead 3400 Base Station equipped with the internal power supply or from the MPS external supply.
The unit allows PowerPlus to provide a continuous 100 Watts of 12VDC with peak output of 150 Watts of 12VDC. Figure 15 - HDX Power Supply Configuration HDX-FR-2 – Two Unit HDX Rack Mount Figure 16 - Two Unit HDX Rack Mount Telecast Fiber Systems – CopperHead 3400 Transceiver System User Guide – Preliminary Version Page 38...
2) Mounting of the optional Power Wafer Unit to the Copperhead 3400 Camera Unit 3) Mounting of the optional PowerPlus Unit to the Copperhead 3400 Camera Unit 4) Relocation of the Copperhead 3400 Base Station Fiber connector from the back panel to the front panel Telecast Fiber Systems –...
(camera model shown for illustrative purposes only – your camera may differ) 2) Attach the CopperHead 3400 Camera Unit to the camera battery mounting plate. The mounting is mechanically identical to attaching a battery. Instructions for attaching the required cables between the camera and the 3400 Camera Unit can be found on Page 57.
1) The CopperHead 3400 Camera Unit is mounted to the camera as described above on the previous page. 2) The Power Wafer is attached to the CopperHead 3400 Camera Unit in place of the battery. It is attached in the same manner as the camera battery.
1) The CopperHead 3400 Camera Unit is mounted to the camera as described above on Page 41. 2) The PowerPlus Unit is attached to the CopperHead 3400 Camera Unit in place of the battery. It is attached in the same manner as the camera battery.
4.4. Relocation of the Copperhead 3400 Base Station Fiber connector The CopperHead 3400 Base Station may be configured with the Fiber Connector mounted either on the back or the front of the Base Station. You may order your Base Station in either configuration and it is possible to relocate the Fiber Connector from one position to the other in the field.
Page 46
A Belden Brand Page Intentionally Left Blank Telecast Fiber Systems – CopperHead 3400 Transceiver System User Guide – Preliminary Version Page 44...
Chapter 5. Connection of the Copperhead 3400 Transceiver System Prior to connecting your Copperhead 3400 Transceiver System please insure that each of the required cables is available for use. This includes standard video, audio and data cables as well as custom multi- pin cable sets required for your particular installation.
The camera must be powered by local power, either a Battery or a local AC Power Supply (6). OpticalCON or MX Fiber Connector directly mounted on the Note: your configuration may have the Base Station Chassis. Telecast Fiber Systems – CopperHead 3400 Transceiver System User Guide – Preliminary Version Page 46...
The Base Station connector (4) may be mounted either on the front or back of the Base Station. The camera will be powered by the CopperHead Power Wafer Camera Power Supply (6). Telecast Fiber Systems – CopperHead 3400 Transceiver System User Guide – Preliminary Version Page 47...
Between the panel mounted receptacle and the Camera Unit is standard Hybrid Fiber Optic cable This cable is matched to the panel mounted receptacle with either an OpticalCON or SMPTE 304M (6). connector Telecast Fiber Systems – CopperHead 3400 Transceiver System User Guide – Preliminary Version Page 48...
The camera will be powered by the CopperHead Power Wafer Camera Power Supply (2). The Base Station will be powered by connection to local AC power (6). Telecast Fiber Systems – CopperHead 3400 Transceiver System User Guide – Preliminary Version Page 49...
The camera will be powered by the CopperHead PowerPlus Camera Power Supply (2). The Base Station will be powered by connection to local AC power (6). Telecast Fiber Systems – CopperHead 3400 Transceiver System User Guide – Preliminary Version Page 50...
D) Audio Out Connector Carries audio back from the camera location – connect to an audio processing chain or monitors. See Page 94 for wiring details Telecast Fiber Systems – CopperHead 3400 Transceiver System User Guide – Preliminary Version Page 51...
Wireless Access Point can be connected to the Production Environment IP network. VBS Out BNC Connector -Typically used for SD Monitoring Video return from the Camera Telecast Fiber Systems – CopperHead 3400 Transceiver System User Guide – Preliminary Version Page 52...
Page 55
BNC Connectors Audio In- Multi-Pin Connector DB25 – 25 pin Connector follows the Tascam TDIF standard. The CopperHead 3400 Transceiver System accommodates up to two Audio Channels at Line Level. This connector handles return audio to the Camera location as well as intercom Program Audio. Please see Page 93 for sample wiring.
This information duplicates some of that from above sections. It is presented here to provide a single list of all Camera Unit connections. Key numbers refer to the diagram above and to the Overview Diagram found in Appendix 6. Telecast Fiber Systems – CopperHead 3400 Transceiver System User Guide – Preliminary Version Page 54...
Multi-Pin Cable Assemblies Used with the Copperhead 3400 Camera Unit A) Camera Remote Control (Remote) Connector Connect this to the CCU input on your camera. The Telecast Fiber System supplied cable has a red sleeve at the end to be connected to the CopperHead 3400 Camera Unit...
Page 58
Fiber Connector Swivel Mounted Fiber Optic Cable receptacle – specific connector depends on your configuration. Intercom Headset Connector Mini-phone Jack – Provides listen only Intercom audio. Telecast Fiber Systems – CopperHead 3400 Transceiver System User Guide – Preliminary Version Page 56...
BNC Connector – Carries a Prompter Feed or additional Base Station return Video from the Camera Unit to the Camera. This requires a BNC cable between the Camera Unit and any external equipment. Telecast Fiber Systems – CopperHead 3400 Transceiver System User Guide – Preliminary Version Page 57...
Camera shown for illustrative purposes only Camera Unit (Camera Facing Side) to Camera Connections Figure 30 - Camera Unit (Camera Facing Side) to Camera Connections Telecast Fiber Systems – CopperHead 3400 Transceiver System User Guide – Preliminary Version Page 58...
A Belden Brand Camera Unit (Power Adaptor or Battery Facing Side) to Camera Connections Camera Unit Video Connections Figure 31 - Camera Unit Video Connections Telecast Fiber Systems – CopperHead 3400 Transceiver System User Guide – Preliminary Version Page 59...
A Belden Brand Camera Unit Audio and Data/Control Connections Figure 32 - Camera Unit Audio and Data/Control Connections Telecast Fiber Systems – CopperHead 3400 Transceiver System User Guide – Preliminary Version Page 60...
Chapter 6. Operation of the Copperhead 3400 Transceiver System This chapter describes in detail the operation of Copperhead 3400 Transceiver System. Please keep in mind that a wide variety of options and variations are available in using this product and so not every possible operational environment can be described.
The following sections provide additional detail on each aspect of setup and operation. It is important that you do an initial setup and test of your Copperhead 3400 Transceiver System as soon as your receive in order to confirm proper operation and to provide training to you and your team prior to an actual production.
4. Deploy the Fiber Cable (see the next section) – you are now ready to Power Up the system. 6.2. Connecting and Managing the Fiber Cable Connecting and managing the Fiber Cable between the CopperHead 3400 Camera Unit and Base Station or an intermediate power supply requires you to perform four tasks: 1.
Place the stationary cable connector inside center of the reel prior to unspooling the cable Telecast Fiber Systems – CopperHead 3400 Transceiver System User Guide – Preliminary Version Page 64...
Page 67
7. When re-spooling the Fiber Cable on to the spool guide it across the entire width of the spool so that it winds evenly and the possibility of cinching or kinks is greatly reduced. Telecast Fiber Systems – CopperHead 3400 Transceiver System User Guide – Preliminary Version Page 65...
A Belden Brand 6.3. Powering the System The CopperHead 3400 Base Station and the CopperHead 3400 Camera Unit each have a power up routine which tests the equipment and performs a system diagnostic. Powering the CopperHead 3400 Base Station Base Station Main Power 1.
User settings for the Intercom system occur on the CopperHead 3400 Camera Unit at the top of the Audio Interface box on the back (not camera facing) side of the Camera Unit Please see the Overview Diagram on Page 98 –...
Figure 34 - Local Activation of Channel 1 Talk Back The Copperhead 3400 Camera Unit allows you to select one or both Intercom Channels to be active. 1. To set listening level for an intercom channel, adjust the desired LISTEN control knobs at the top of the Audio Interface box.
Talk Switch is inactive. The selection of the active Talk Back Intercom Channel is identical to that when the Intercom Local/Remote Switch is in LOCAL. Telecast Fiber Systems – CopperHead 3400 Transceiver System User Guide – Preliminary Version Page 69...
The minimum recommended signal strength is -22 dBm or better. Typically the system should operate at levels between -8 dBm and -20 dBm. The standard CopperHead 3400 laser output strength is -6 dBm. Cable length affects signal strength as does the number of connections between the Camera Unit and the Base Station.
Page 73
This display cycle repeats itself and depending on timing may start with either OPT of the strength measurement – ROPT does not reappear in the repeating cycle Telecast Fiber Systems – CopperHead 3400 Transceiver System User Guide – Preliminary Version Page 71...
Page 74
Instead of OK, the display will show ERR if a power level is outside of DIAG/POWER normal – ERR is followed by a Hexadecimal code. Please note the error code and contact support at Telecast-Fiber. Telecast Fiber Systems – CopperHead 3400 Transceiver System User Guide – Preliminary Version Page 72...
Page 75
Indicates that the Camera Unit is reporting No fault DIAG/CAM Indicates that the Camera Unit is reporting Some fault This display cycle repeats until the Display Mode Selector is pushed Telecast Fiber Systems – CopperHead 3400 Transceiver System User Guide – Preliminary Version Page 73...
This display cycle repeats itself and depending on timing may start with either OPT of the strength measurement – ROPT does not reappear in the repeating cycle Telecast Fiber Systems – CopperHead 3400 Transceiver System User Guide – Preliminary Version Page 74...
Page 77
Indicates that mode is REV UBUS Indicates the UBUS microcontroller board is revision is being queried REVA Indicates that the REV for the UBUS board is REVA Telecast Fiber Systems – CopperHead 3400 Transceiver System User Guide – Preliminary Version Page 75...
Page 78
The four character Digital Display will indicate maximum brightness with this readout <-> The four character Digital Display will indicate minimum brightness with this readout Telecast Fiber Systems – CopperHead 3400 Transceiver System User Guide – Preliminary Version Page 76...
A Belden Brand 6.6. Standard Operation The section is devoted to a number of “Best Practices” for use of the CopperHead 3400 Transceiver System. Specific information on how to operate the system has been presented in the sections above. 1. Protect the Fiber Optic Cable and the Fiber Optic Connectors. Always keep these capped unless there are being connected.
Re-spool evenly across the reel. 6. If the Base Station is a permanent or semi-permanent installation then simply power off and disconnect and cap the Fiber Cable. Telecast Fiber Systems – CopperHead 3400 Transceiver System User Guide – Preliminary Version Page 78...
6. If the digital display indicates an error and displays a Hexadecimal error code you should contact Telecast Fiber support to assist in diagnosing the problem. Note the exact error code so you can report it to Telecast Fiber support. The hexadecimal errors indicate problems with the power supplies and the internal boards.
Page 82
A Belden Brand Page Intentionally Left Blank Telecast Fiber Systems – CopperHead 3400 Transceiver System User Guide – Preliminary Version Page 80...
+12VDC Bias for Format Table 7 - Base Station Tally/GPI Connector Wiring This cable is end-user supplied. Please see Appendix 4 – Page 92 for suggested wiring configuration Telecast Fiber Systems – CopperHead 3400 Transceiver System User Guide – Preliminary Version Page 81...
12VDC camera power supply Molex Connector –5 Pin Connector Wiring Function Wire Color White* Black* Ground Green Base Station #24 *Tied together at terminal lug end Telecast Fiber Systems – CopperHead 3400 Transceiver System User Guide – Preliminary Version Page 82...
Pin Function Minus Voltage Terminal Plus Voltage Terminal Table 13 - Base Station 12VDC Terminal Block Wiring Base Station #23 This cable is end-user supplied Telecast Fiber Systems – CopperHead 3400 Transceiver System User Guide – Preliminary Version Page 83...
+12VDC Bias for Format Table 15 - Camera Unit Production DB15HD Connector Wiring Please see Appendix 3 for a list of Telecast Fiber System supplied Camera Remote Cables. Telecast Fiber Systems – CopperHead 3400 Transceiver System User Guide – Preliminary Version Page 84...
Channel B/D (-) OUT Channel B/D (+) OUT Table 18 - Camera Unit Audio 1 & 2 Connector Wiring Camera Unit #4-5-6 This cable is end-user supplied Telecast Fiber Systems – CopperHead 3400 Transceiver System User Guide – Preliminary Version Page 85...
A Belden Brand Appendix 2. Configuring Tally for the CopperHead 3400 Transceiver System Figure 38 - Simple LED Tally Wiring Diagram Telecast Fiber Systems – CopperHead 3400 Transceiver System User Guide – Preliminary Version Page 86...
OpticalCON connector Cable Assembly, SMPTE 304M connectors CH3-BS-95VD-304 or MXRE -NEU or –STM Base Station MX Receptacle Flange Mount Assembly Breakout to w/internal Power Supply Telecast Fiber Systems – CopperHead 3400 Transceiver System User Guide – Preliminary Version Page 87...
Page 90
Camera Remote Cable, 10 Rack mount frame for 2 foot HDX units. (specify remote model) CH2-MPS-95VD-2ST-XXX or CH2-MPS-95VD-NEU-XXX Power Supply for Power Wafer Power Adaptor Telecast Fiber Systems – CopperHead 3400 Transceiver System User Guide – Preliminary Version Page 88...
Page 91
Base Fiber Plates - powered: Camera Signal Cable 26-pin ST /Molex or OpticalCON Multicore or 304M CHRCP-2050A CHRCP-2050-LCD Universal Camera Control Universal Camera Control Panel Panel w/TFT-LCD Display Telecast Fiber Systems – CopperHead 3400 Transceiver System User Guide – Preliminary Version Page 89...
RCP-D50 HR10A-10P-10P (10 pin) (no VTR) For information on these and other cable configurations please contact Telecast Fiber Systems, Inc. or your local CopperHead dealer. Telecast Fiber Systems – CopperHead 3400 Transceiver System User Guide – Preliminary Version...
A Belden Brand Appendix 4. Multi-Pin Wiring Suggestions Base Station Breakout Data/GPI Cable for CopperHead 3400 Figure 39 - Base Station Breakout Data/GPI Cable for CopperHead 3400 Telecast Fiber Systems – CopperHead 3400 Transceiver System User Guide – Preliminary Version Page 92...
A Belden Brand CopperHead 3400 Base Station 25-Pin Audio Input Cable Figure 40 - CopperHead 3400 Base Station 25-Pin Audio Input Cable Telecast Fiber Systems – CopperHead 3400 Transceiver System User Guide – Preliminary Version Page 93...
A Belden Brand CopperHead 3400 Base Station 25-Pin Audio Output Cable Figure 41 - CopperHead 3400 Base Station 25-Pin Audio Output Cable Telecast Fiber Systems – CopperHead 3400 Transceiver System User Guide – Preliminary Version Page 94...
Telecast Fiber Systems – CopperHead 3400 Transceiver System User Guide – Preliminary Version Page 95...
Page 98
A Belden Brand Page Intentionally Left Blank Telecast Fiber Systems – CopperHead 3400 Transceiver System User Guide – Preliminary Version Page 96...
A Belden Brand Appendix 6. CopperHead 3400 Transceiver System Overview Telecast Fiber Systems – CopperHead 3400 Transceiver System User Guide – Preliminary Version Page 97...
Page 100
A Belden Brand Page Intentionally Left Blank Telecast Fiber Systems – CopperHead 3400 Transceiver System User Guide – Preliminary Version Page 98...
A Belden Brand Camera Unit Indicators and Controls *Appears only on Hybrid Power Systems CopperHead Base Station Front Panel Telecast Fiber Systems – CopperHead 3400 Transceiver System User Guide – Preliminary Version Page 99...
Page 102
A Belden Brand End Page Telecast Fiber Systems – CopperHead 3400 Transceiver System User Guide – Preliminary Version Page 100...
Need help?
Do you have a question about the CopperHead 3400 and is the answer not in the manual?
Questions and answers