Siemens SIMATIC IPC477E Operating Instructions Manual

Siemens SIMATIC IPC477E Operating Instructions Manual

Hide thumbs Also See for SIMATIC IPC477E:
Table of Contents

Advertisement

SIMATIC
Industrial PC
SIMATIC IPC477E
Operating Instructions
12/2016
A5E37455003-AB
___________________
Preface
___________________
Overview
___________________
Safety instructions
___________________
Mounting and connecting the
device
___________________
Commissioning the device
___________________
Operating the device and
device functions
___________________
Expanding the device and
assigning device parameters
___________________
Maintaining and servicing
your device
___________________
Technical information
___________________
Technical support
___________________
Markings and symbols
___________________
List of abbreviations
1
2
3
4
5
6
7
8
A
B
C

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC IPC477E

  • Page 1 ___________________ Preface ___________________ Overview ___________________ SIMATIC Safety instructions ___________________ Mounting and connecting the device Industrial PC SIMATIC IPC477E ___________________ Commissioning the device ___________________ Operating the device and device functions Operating Instructions ___________________ Expanding the device and assigning device parameters ___________________...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Preface

    General knowledge in the field automation control engineering is recommended. Scope of the operating instructions These operating instructions apply to "SIMATIC IPC477E" industrial PCs with article numbers 6AV7241... (built-in unit). Scope of this documentation The documentation for the IPC includes the following: ●...
  • Page 4 Conventions In these operating instructions, "device" is used as the standard term for "SIMATIC IPC477E" (built-in unit). In these operating instructions, the terms "Windows Embedded Standard 7 P" and "Windows Embedded Standard 7 E" are also abbreviated with the term "Windows Embedded Standard".
  • Page 5: Table Of Contents

    Connecting the 24 V DC power supply ................... 49 3.3.3 Connecting peripheral equipment ................... 51 3.3.4 Connecting the device to networks ..................52 3.3.5 Securing cables on the built-in unit ..................53 3.3.5.1 Attaching the strain relief ......................53 SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 6 Built-in unit ..........................91 7.4.1.1 Replacing back-up battery (devices with 15", 19" or 22" display) .......... 91 7.4.1.2 Replacing the SSD (devices with 15", 19" or 22" display) ............. 93 7.4.1.3 Replacing HDD ........................95 SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 7 8.5.1.6 USB 2.0 ..........................141 8.5.2 Internal ports ......................... 142 8.5.2.1 PCIe card ..........................142 8.5.3 System resources ......................... 144 8.5.3.1 Currently allocated system resources ................... 144 8.5.3.2 Assignment of system resources ..................144 SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 8 Markings and symbols ........................... 167 Overview ..........................167 Safety ........................... 167 Operator controls ......................... 167 Certificates, approvals and markings ................... 168 Interfaces ..........................168 List of abbreviations ..........................171 Glossary ..............................177 Index ..............................185 SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 9: Overview

    Overview Product description Figure 1-1 Built-in unit with resistive single touch screen SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 10 The delivery note contains information on the precise scope of functions and product package for your device. The SIMATIC IPC477E is available in the following device variants, which differ in regard to the display size, operating method and optional expansions: Devices with resistive single touch screen ●...
  • Page 11 Built-in units with capacitive multi-touch screen ● Display: – 15.6" display, resolution: 1366 x 768 pixels – 19" display, resolution: 1366 x 768 pixels – 22'' display, resolution: 1920 x 1080 pixels ● With PCIe slot SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 12: Design Of The Built-In Units

    The bottom view shows a device with 24 V DC power supply. ① Recesses for one mounting clip each Rear view ① Rating plate ② Rear panel / rear panel of expansion ③ Labeling for the interface arrangement SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 13: Devices With Capacitive Multi-Touch Screen

    Recesses, each of which for a mounting clip ② Display with touch screen Bottom view ① Recesses for one mounting clip each Rear view ① Rating plate ② Rear panel ③ Labeling for the interfaces SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 14: Devices With Expansions

    Devices with PCIe card The following figures show the 15" device with resistive single-touch screen and a PCIe expansion as an example. Rear view and side view ① Rear panel ② PCIe card Bottom view SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 15: Interfaces And Operator Controls For Devices With 24 V Dc Power Supply

    ⑥ Display port ⑦ Display port ⑧ 3 × Ethernet port 3 x RJ45 (10/100/1000 Mbps) ⑨ COM1 port (optional) Serial interface, 9-pin D-Sub pin ⑩ COM2 port (optional) Serial interface, 9-pin D-Sub pin SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 16: Accessory Kit

    Additional documents may be enclosed with the accessory kit. Accessories Accessories are available for your device. These are not included in the product package. You can find Information on available accessories on the Internet at: Industry Mall (https://mall.industry.siemens.com) Expansion components and accessories (http://www.automation.siemens.com/mcms/pc- based-automation/en/industrial-pc/expansion_components_accessories) SIMATIC IPC CFast cards ●...
  • Page 17 Other accessories ● Touch stylus only for devices with resistive single-touch screen ● Mounting bracket If there are higher requirements for the front seal, fasten the device with mounting brackets in a control cabinet. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 18 Overview 1.4 Accessories SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 19: Safety Instructions

    Note that the built-in unit is classified as "Open Type" for use in the area of Industrial Control Equipment (UL508). The installation of the built-in unit in an enclosure conforming to UL508 is a mandatory requirement for approval and operation in accordance with UL508. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 20 When you touch electrostatic sensitive components, you can destroy them through voltages that are far below the human perception threshold. If you work with components that can be destroyed by electrostatic discharge, observe the ESD Guideline (Page 114). SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 21 In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement – and continuously maintain – a holistic, state-of-the-art industrial security concept. Siemens’ products and solutions only form one element of such a concept. Customer is responsible to prevent unauthorized access to its plants, systems, machines and networks.
  • Page 22: Notes On Usage

    • Observe the permitted mounting positions of the device. • Do not obstruct the venting slots of the device. • Always use suitable cleaning agents. Read the information about Chemical resistance of the HMI devices and industrial PCs (http://support.automation.siemens.com/WW/view/en/39718396) on the Internet. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 23 Use in an industrial environment without additional protective measures The device has been designed for use in a normal industrial environment in accordance with IEC 60721-3-3 (pollutant class 3C2 for chemical influences, 3S2 for dust without sand). SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 24 Safety instructions 2.2 Notes on usage SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 25: Mounting And Connecting The Device

    • Keep the original packaging. • Pack the device in the original packaging for transportation and storage. 5. Check the contents of the packaging and any accessories you may have ordered for completeness and damage. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 26 7. Please keep the enclosed documentation in a safe place. It belongs to the device. You need the documentation when you commission the device for the first time. 8. Write down the identification data of the device. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 27: Device Identification Data

    Only devices with preinstalled Windows operating systems Certificate of Authenticity (COA) have the COA label Ethernet address 1 BIOS setup, "Advanced" menu Ethernet address 2 Ethernet address 3 Example of rating plate on SIMATIC IPC477E SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 28 The COA label is present only when Windows Embedded Standard 7 or Windows 7 is installed. ● COA label of a device with the Windows Embedded Standard 7 operating system ● COA label of a device with Windows operating system SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 29: Built-In Unit

    ● Standard mounting position: Vertical installation in horizontal format In this mounting position, the device enclosure satisfies the requirements of a fire protection enclosure. For temperature specifications, see section "Environmental conditions (Page 133)". SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 30 4.6 and 4.7.3 of the IEC/UL/EN/DIN-EN 60950-1 standard. Display rotated 90° vertical from the standard position. The power supply is located at the top. For temperature specifications, see section "Environmental conditions (Page 133)". SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 31: Preparing The Mounting Cutout

    ● Permitted deviation from plane at the mounting cutout: ≤ 0.5 mm This condition must be fulfilled for the mounted HMI device. ● Permissible surface roughness in the area of the mounting seal: ≤ 120 µm (R 120) Dimensions of the mounting cutout SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 32 Width and height must be interchanged for mounting in vertical format. Device with capacitive multi-touch screen Device with resistive single touch screen Installation depth Information on the overall depth is available in the section "Dimension drawings (Page 117)". SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 33: Installing The Built-In Unit

    ● Provide adequate volume in the control cabinet for air circulation and heat transport. Keep at least 5 cm distance between the device and control cabinet. ● The ventilation slots of the device may not be covered or obstructed. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 34 ● Ensure there is enough clearance in the control cabinet to allow the backplane cover to be removed. ● Equip the control cabinet with struts for stabilizing the mounting cut-out. Install struts where necessary. See also Dimension drawings (Page 117) Technical specifications (Page 129) SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 35: Mounting Clips Or Mounting Brackets, Position For Ip65-Compliant Installation

    To achieve IP65 degree of protection for the device, the mounting clips or mounting brackets must be installed at the positions shown below. Device Position Touch screen device with: 15" display • 19" display • 22" display • SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 36: Mounting The Device With Mounting Clips

    Procedure Note If the mounting seal is damaged or protrudes from the device, the guaranteed degree of protection is not ensured. It is prohibited from mounting the device if the mounting seal is damaged. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 37 0.5 Nm. Repeat steps 2 and 3 for all mounting clips. Check the fit of the mounting seal. Mounting clips for devices with 15", 19" or 22" display SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 38: Mounting The Device With Mounting Brackets

    ● 2.5 mm hexagonal spanner Procedure Note If the mounting seal is damaged or protrudes over the device, the degree of protection is not guaranteed. Working from the front, insert the device into the mounting cut-out. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 39 • Installation with mounting clamps • The circumferential seal is properly attached to a correctly sized cutout. • Follow the instructions when measuring the dimensions as shown in the section "Preparing the mounting cutout (Page 31)". SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 40: Position Of The Mounting Clips For Ip66-Complaint Installation

    4 additional mounting clips (available as accessories) at the positions marked by the red boxes. The 15" display meets IP66 even without additional mounting clips. Device Position Touch screen device with: 19" display • 22" display • SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 41: Connecting The Device

    • Only connect I/O devices which are approved for industrial applications in accordance with EN 61000-6-2 and IEC 61000-6-2. • I/O devices that are not hotplug-capable may only be connected after the device has been disconnected from the power supply. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 42 Regenerative feedback of voltage to ground by a connected or installed component can damage the device. Connected or built-in I/Os, for example, a USB drive, are not permitted to supply any voltage to the device. Regenerative feedback is generally not permitted. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 43: Power Supply Built-In Unit

    • If a device is defective, decommission it without delay and mark it accordingly. Requirement ● The device is installed ● 1 protective conductor with minimum core cross-section of 2.5 mm ● 1 T20 screwdriver ● 1 cable lug for M4 SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 44 2. Connect the cable lug to the screw at the designated protective conductor connec- tion. 3. Connect the protective conductor to the protective conductor connection of the control cabinet in which the device is installed. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 45: Connect 100-240 Vac Power Supply

    SIMATIC IPCs with an active PFC. UPS characteristics are described and classified in the standards EN 50091-3 and IEC 62040-3. Devices with sinusoidal output voltage in the normal and buffered mode are identified with the classification "VFI-SS-.." or "VI-SS-..". SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 46 Requirement ● The device is installed. ● The protective conductor is connected, see the section "Connecting the protective earth (Page 43)". SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 47 The on/off switch does not disconnect the device from the power supply system. Always unplug the power plug to disconnect the device from the power supply system. Perform the steps for connecting the power supply cord in reverse order. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 48: Connecting The Terminal

    Make sure that the cores are connected to the correct terminals. Observe the labeling for the contacts on the front cover of the device. 1. Connect the lines as shown. Make sure the connection terminal is in the correct position as shown. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 49: Connecting The 24 V Dc Power Supply

    Requirements ● The device is installed. ● The protective conductor is connected. ● The connection terminal is wired. ● The corresponding 24 V DC power supply is switched off. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 50 3.3 Connecting the device Procedure Switch off the 24 V DC power supply. Connect the wires of the power supply. Connect the connection terminal at the marked position. Secure the connection terminal with the marked screws. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 51: Connecting Peripheral Equipment

    The product supplier in each case provides support for the USB devices. Moreover, the terms of liability of the individual vendors or suppliers apply here. Note Strain relief Use the metal eyelets on the rear side to mount the cable strain reliefs for cable ties. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 52: Connecting The Device To Networks

    Control level. Information on this can be found on the SIMATIC NET Manual Collection CD. The software package and the documentation are not included in the product package. Additional information You can find additional information on the Internet at: Technical Support (https://support.industry.siemens.com) SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 53: Securing Cables On The Built-In Unit

    Installation the 24 V DC power supply connection The 24 V DC power supply connec- tion is screwed on to the device at the marked positions. Secure the connection cable to the nearest at- tachment eyelet with a cable tie. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 54 Installation of the strain relief for the DP and USB connections 1. Screw on the strain relief with a screw at the marked positions. 2. Clip on the connector. 3. Secure each connector with a cable tie. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 55 Installation of the strain relief for the different connectors 1. Screw on the strain relief with screws at the marked positions. 2. Secure each connector with a cable tie. Removal Perform the steps for attaching the strain relief in reverse order. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 56 Mounting and connecting the device 3.3 Connecting the device SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 57: Commissioning The Device

    ● The device is connected to the power supply. ● The protective conductor is connected. ● The connection cables are plugged in correctly. ● The following hardware is available for initial commissioning: – One USB keyboard – One USB mouse SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 58: Initial Commissioning

    The product key is located on the "Certificate of Authentication", in the "Product Key" line. Result The interface of the operating system is displayed every time you turn on the device and after the startup routine. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 59 If the device is not going to be used for a long period of time after shutdown, set the on/off switch to the position. NOTICE Disconnecting the device from the power supply The on/off switch does not separate the device from the mains. To de-energize the device, remove the power supply terminal. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 60: Windows Action Center

    Windows settings. You can then either acknowledge this warning or prevent the program from changing the Windows settings. This option is enabled for Windows 7 and Windows Embedded Standard 7 with the factory settings. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 61: Operating The Device And Device Functions

    Do not touch the touch screen with pointed or sharp objects. Only touch the touch screen with your fingers, a touch stylus or an approved touch glove. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 62: Operating A Device With Resistive Single Touch Screen

    Appearance of blisters under extreme ambient conditions Under extreme environmental conditions such as high atmospheric humidity and temperature, bubbles can form on the touch surface in rare cases. This only affects the appearance and does not represent any functional restriction. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 63: Operating A Device With Capacitive Multi-Touch Screen

    Functions may not work properly. This can result in personal injury or property damage. • Always connect the device to a protective conductor. • Additional information on connecting the protective conductor can be found in the section "Connecting the protective earth (Page 43)." SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 64 ● There is a conductive liquid on the touch screen with ground contact via the enclosure or the operator, for example. ● Electromagnetic interference is present that exceeds the specification according to EN 61000-4-2. Once the interference is over, the touch screen is no longer locked. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 65: Ipc Driver And Tools

    ● Configuration via the IPC Configuration Center of: – Brightness – Screen saver – Tools – Touch settings – Ethernet Monitor settings All other functions are described in the IPC Panel Driver and Tools operating manual. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 66: Extended Device Functions

    SIMATIC IPC DiagMonitor is available on CD (not included in the scope of delivery). The CD contains both the monitoring software and the software for the stations to be monitored. The interface specifications and a library for creating your own applications are also provided. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 67: Temperature Monitoring/Display

    The temperature error is saved until the temperatures have fallen below the thresholds and it is reset by one of the following measures: ● Acknowledgment of the error message by the user with DiagBase or DiagMonitor software ● Restart of the device SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 68: Watchdog (Wd)

    Windows and damage to the installation. Watchdog monitoring times The monitoring time can be configured with the DiagBase or DiagMonitor software. Note When you change the monitoring time, the change becomes effective immediately. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 69: Battery Monitoring

    When the first warning level is reached, the battery for buffering CMOS data still has a remaining service life of at least one month. 5.5.1.5 Mass storage monitoring The state of HDD, SSD and CFast cards is monitored via SMART bit and reported by DiagBase or DiagMonitor. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 70: Enhanced Write Filter (Ewf)

    The SIMATIC IPC EWF Manager is preinstalled and included on the supplied USB stick (DocuAndDrivers\Drivers). Start the SIMATIC IPC EWF Manager as follows: ● "Start > All Programs >Siemens Automation > SIMATIC > EWF Manager > EWF Manager" SIMATIC IPC477E...
  • Page 71 5.5 Extended device functions Configure the SIMATIC IPC EWF Manager as follows: ● "Start > All Programs > Siemens Automation > SIMATIC > EWF Manager > EWF Settings" ● Click the "SIMATIC IPC EWF Manager" icon in the system tray.
  • Page 72 "Start > Control Panel > Date and Time", remove the check mark from the "Automatically adjust clock for daylight saving changes" check box. 2. Save the change you have made with and then reboot the system. ewfmgr c: commit SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 73: File Based Write Filter (Fbwf)

    This may damage the machine or plant. Make sure that you only activate one write filter for each partition. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 74: Buffer Memory Nvram

    A memory window with a maximum size of 512 KB can be displayed by means of PCI address register. The base address is initialized by the BIOS. A corresponding function is implemented there for using the NVRAM under WinAC RTX and for using the CPU150xS SW controller. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 75: Active Management Technology (Amt)

    SIMATIC IPC Remote Manager The "SIMATIC IPC Remote Manager" software is available for utilization of the AMT functions with SIMATIC IPCs. The software can be ordered from the Siemens online ordering system. For detailed information about "SIMATIC IPC Remote Manager", refer to the corresponding product documentation: SIMATIC IPC Remote Manager (http://support.automation.siemens.com/WW/view/en/48707158)
  • Page 76 Configuration of the AMT PC You configure AMT by means of the BIOS setup and MEBx (Management Engine BIOS Extension). MEBx is a BIOS extension for configuration of AMT (see BIOS description in chapter "Technical specifications"). SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 77: Trusted Platform Modul (Tpm)

    The warranty does not cover a reset of the hardware in the event of a loss of a password. Please store the password carefully and make sure it is protected against unauthorized access. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 78 Operating the device and device functions 5.5 Extended device functions SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 79: Expanding The Device And Assigning Device Parameters

    For devices without expansions, only the rear panel of the device is removed. Requirement ● The device is disconnected from the power supply. ● All cables are removed from the device. ● The device is removed. ● T10 screwdriver SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 80 2. Loosen the screws marked in green. Position and number of the fastening screws are the same for the devices with 15", 19" and 22" display. 3. Remove the rear panel of the device. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 81: Installing And Removing A Memory Module

    The motherboard is equipped with one slot for an SO-DIMM DDR4 memory module. You can use it to expand the memory capacity of the device to a maximum of 32 GB. Note Use only the memory modules recommended by Siemens AG. You can find additional information in the section "Accessories (Page 16)". Requirements ●...
  • Page 82 Installation 1. Insert the memory module into the marked slot at an incline with the contact side toward the motherboard. 2. Carefully press the memory module into the contact strip until the latches engage. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 83: Installing And Removing A Pcie Card (Built-In Units With Pcie Card)

    Note the protective measures required when working with ESD in the section "ESD guideline (Page 114)". Installation 1. Remove the marked screws and take off the rear panel of the of the enclosure. 2. Remove the marked screws and pull out the blanking plate. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 84 5. Push the PCIe card holder in the direc- tion of the PCIe card and secure this with the marked screw. 6. Close the device. Removal Follow the steps for installation in reverse order. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 85: Installing And Removing A Cfast Card

    If you are using the memory card in a device installed in a system, you must observe the safety regulations for work on electrical systems. Note Carefully insert the CFast card into the slot without applying excess force. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 86: Assigning Cpu Power Consumption Parameters

    Same as standard, but additionally optimized for deterministic operation with optimized constant CPU frequency. Temperature Setting for lowest power consumption. optimized The CPU clock is limited at a higher load. The maximum power consumption of the CPU is 12 W. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 87: Maintaining And Servicing Your Device

    Unauthorized opening and improper repairs on the device may result in substantial damage to equipment or endanger the user. If you install or replace a system expansion and damage your device, the warranty will become void. The device may only be repaired by qualified personnel. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 88 Do not recharge, open, or short lithium batteries. Do not reverse lithium battery polarity or heat the batteries to over 100°C. Keep lithium batteries out of direct sunlight and protect them from moisture and condensation. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 89 UL approval of the device only applies when the UL-approved components are used according to their "Conditions of Acceptability". We are not liable for functional limitations caused by the use of third-party devices or components. See also Spare parts and repairs (http://support.automation.siemens.com/WW/view/en/16611927) SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 90: Cleaning The Device Front

    • Compressed air Procedure 1. Switch off the device. 2. Dampen the cleaning cloth. 3. Spray the cleaning agent on the cloth and not directly on the device. 4. Clean the device with the cleaning cloth. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 91: Installing And Removing Hardware

    Make a note of the current BIOS setup settings or save them as a user profile in the BIOS setup Exit menu. You will find a list for noting the settings in the BIOS description. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 92 2. Grip the marked battery and pull it up and out of its holder. Installation For installation, follow the removal steps in reverse order and close the device. See also General safety instructions (Page 19) Repair information (Page 87) SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 93: Replacing The Ssd (Devices With 15", 19" Or 22" Display)

    ● The device is disconnected from the power supply. ● The device is open, see the section "Opening the device (Page 79)". ● SSD ● T10 screwdriver Procedure Removal 1. Remove the marked screws. 2. Remove the connectors from the port. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 94 • Screws to fasten the hard disk holder to the device (long screws) Make sure you use the correct screws for each operation. For installation, follow the removal steps in reverse order and close the device. See also Repair information (Page 87) SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 95: Replacing Hdd

    3. Remove the connector in the direction of the arrow. 4. Detach the hard disk from the base plate. Remove the four screws that connect the hard disk and the base plate. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 96 • Screws to fasten the hard disk holder to the device (long screws) Make sure you use the correct screws for each operation. For installation, follow these steps in reverse and close the device. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 97: Installing The Software

    The supplied USB stick contains the documentation, hardware drivers and updates. In Windows, these contents are available via a menu. Restore function If you have ordered IPC477E with operating system, the supplied USB stick contains the Restore function. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 98: Restoring The Delivery State

    4. To boot from the USB stick, select the Boot Manager. 5. Select the USB stick in the Boot Manager and confirm the entry. 6. Select the Restore function and confirm the entry. 7. Follow the on-screen instructions. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 99: Windows 7

    The BIOS selection menu is displayed when initialization is completed. 4. To boot from the USB stick, select the Boot Manager. 5. Select the USB stick in the Boot Manager and confirm the entry. 6. Select the Recovery function and confirm the entry. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 100 For this purpose, you can either select one of the preinstalled languages or install a new language package. The following command sequences are described in English. Depending on the default setting, they can be displayed in another language. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 101 1. Choose: "Start > Control Panel > Clock, Language, and Region > Regional and Language Options" 2. Select the "Keyboards and Languages" tab. 3. Click the "Install/uninstall languages" button and make the required changes. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 102 Maintaining and servicing your device 7.5 Installing the software The following languages can be installed at a later time: Language Windows 7 German English French Italian Spanish Chinese (Hong Kong) Chinese (simplified) Chinese (Taiwan) Japanese Russian SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 103: Windows Embedded Standard 7

    Note the license terms of Windows Embedded Standard 7 Note the license terms for Windows Embedded Standard 7 and especially the extended software terms of the Siemens AG. You can find the license terms in the delivered document "MICROSOFT SOFTWARE LICENSE TERMS for Windows Embedded Standard 7"...
  • Page 104 8. After selecting the menu dialog language, select the menu entry "Manage language packages". Depending on the current language setup, you have the following options in the "Manage language packages" menu: – Display language settings – Install language – Change language – Uninstall installed language SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 105: Partitioning Data Media

    Second Data Remainder Remainder NTFS not compressed To restore the partitions to their original delivery state, we recommend the software SIMATIC IPC Image & Partition Creator. Additional information is available in the accompanying documentation. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 106: Partitioning In Windows 7 Ultimate

    Procedure - Reduce partition A partition can only be reduced if sufficient space is available. 1. Click with the right mouse button on the partition to be reduced and click on "Reduce size". 2. Follow the instructions. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 107 1. Click in the partition manager with the right mouse button on the partition to be increased and click on "Increase size". 2. Follow the instructions on the screen. Additional information is available in the "Help" menu under "Help topics" and "Search". SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 108: Installing Drivers And Software

    6. Open the folder with the driver data by clicking on the link next to "Driver path". 7. Start the setup program in this folder. Note For a new installation of Windows operating systems, the chipset driver must be installed before all other drivers, if required. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 109: Update Installation

    (images). The SIMATIC IPC Image & Partition Creator can be ordered using the Siemens online ordering system (https://mall.industry.siemens.com). For more information about SIMATIC IPC Image & Partition Creator, refer to its product documentation.
  • Page 110 Maintaining and servicing your device 7.6 Recycling and disposal SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 111: Technical Information

    Panel PC certificates (http://support.automation.siemens.com/WW/view/en/10805572/134200). ISO 9001 certificate The Siemens quality management system for our entire product creation process (development, production and sales) meets the requirements of ISO 9001:2008. This has been certified by DQS (the German society for the certification of quality management systems).
  • Page 112 This product meets the requirements of Korean certification. This product satisfies the requirement of the Korean Certification (KC Mark). 이 기기는 업무용(A급) 전자파 적합기기로서 판매자 또는 사용자는 이 점을 주의하시기 바라며 가정 외의 지역에서 사용하는 것을 목적으로 합니다. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 113: Directives And Declarations

    EN 61000-3-3 (voltage fluctuations and flicker). Low-voltage directive The device with AC power supply complies with the requirements of the EU Directive 2014/35/EU "Low Voltage Directive". Conformance with this standard has been verified according to EN 60950-1. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 114: Esd Guideline

    The consequences are incalculable and range from unforeseeable malfunctions to a total failure of the machine or system. Avoid touching components directly. Make sure that persons, the workstation and the packaging are properly grounded. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 115 There is no equipotential bonding without grounding. An electrostatic charge is not discharged and may damage the ESD. Protect yourself against discharge of static electricity. When working with electrostatic sensitive devices, make sure that the person and the workplace are properly grounded. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 116 This way, the discharge energy does not reach and damage the sensitive components. – Discharge your body electrostatically before you take a measurement at a module. Do so by touching grounded metallic parts. Always use grounded measuring instruments. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 117: Dimension Drawings

    The figure shows the front view and directly associated side view and top view of a device without PCI expansion. The side view and top view of a device with PCI expansion are shown beyond at a distance. Device without PCI expansion Device with PCI expansion SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 118 Technical information 8.3 Dimension drawings All dimensions in mm. Device depths 75.5 mm • Without expansion cards: 102.5 mm • With PCIe card: SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 119: Dimension Drawing Of 19" Device With Capacitive Multi-Touch Screen

    The figure shows the front view and directly associated side view and top view of a device without PCI expansion. The side view and top view of a device with PCI expansion are shown beyond at a distance. Device without PCI expansion Device with PCI expansion All dimensions in mm. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 120 Technical information 8.3 Dimension drawings Device depths 75.5 mm • Without expansion cards: 102.5 mm • With PCIe card: SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 121: Dimension Drawing Of 22" Device With Capacitive Multi-Touch Screen

    The figure shows the front view and directly associated side view and top view of a device without PCI expansion. The side view and top view of a device with PCI expansion are shown beyond at a distance. Device without PCI expansion Device with PCI expansion SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 122 Technical information 8.3 Dimension drawings All dimensions in mm. Device depths 75.4 mm • Without expansion cards: 102.5 mm • With PCIe card: SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 123: Dimension Drawing Of 15" Device With Resistive Single-Touch Screen

    The figure shows the front view and directly associated side view and top view of a device without PCI expansion. The side view and top view of a device with PCI expansion are shown beyond at a distance. Device without PCI expansion Device with PCI expansion SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 124 Technical information 8.3 Dimension drawings All dimensions in mm. Device depths 75.5 mm • Without expansion cards: 106.1 mm • With PCIe card: SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 125: Dimension Drawing Of 19" Device With Resistive Single-Touch Screen

    The figure shows the front view and directly associated side view and top view of a device without PCI expansion. The side view and top view of a device with PCI expansion are shown beyond at a distance. Device without PCI expansion Device with PCI expansion All dimensions in mm. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 126 Technical information 8.3 Dimension drawings Device depths 76.1 mm • Without expansion cards: 106.1 mm • With PCIe card: SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 127: Dimension Drawing Of 22" Device With Resistive Single-Touch Screen

    The figure shows the front view and directly associated side view and top view of a device without PCI expansion. The side view and top view of a device with PCI expansion are shown beyond at a distance. Device without PCI expansion Device with PCI expansion SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 128 Technical information 8.3 Dimension drawings All dimensions in mm. Device depths 75.5 mm • Without expansion cards: 106.1 mm • With PCIe card: SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 129: Technical Specifications

    The table below shows the maximum power consumption of the devices with and without expansion. Device type Without expansion With PCIe 15" Touch 70 W 77 W 19" Touch 78 W 85 W 22" Touch 75 W 82 W SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 130 16 GB DDR4-SDRAM SODIMM • Memory module with ECC (not combinable with i5 CPU): 8 GB DDR4-SDRAM SODIMM • 16 GB DDR4 SDRAM SODIMM • Backup memory 512 kB NVRAM optional For devices with retentivity SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 131 MTBF: Operating hours after which the maximum brightness is reduced by half compared to the original value. MTBF is increased by using the integrated dimming function, for example, time- controlled via screen saver or centrally via PROFIenergy. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 132 For unique labeling, the Ethernet ports are numbered on the enclosure. The numbering by the operating system can differ. Teaming can be set and initiated in the configuration interface. In teaming operation, jumbo frames, e.g. for the camera application, are not supported. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 133: Environmental Conditions

    -20 °C to +60 °C vices Storage/transport, gradient Max. 20 °C/h, no condensation Note: The ambient temperature must be reduced by 5 °C for the setting "Performance Optimized" (see Assigning CPU power consumption parameters (Page 86)). SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 134 5 to 8.4 Hz: 3.5 mm 8.4 Hz to 500 Hz: 9.8 m/s Shock resistance, tested in accordance with IEC 60068-2-27, IEC 60068-2-29 Operation 50 m/s , 30 ms Storage/transport 250 m/s , 6 ms SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 135: Power Requirements Of The Components

    The peak value of the starting current depends on the input voltage and the impedance of the 24 V DC power supply. Peak currents greater than 6.5 A are possible. This will not have a negative impact on device functionality. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 136: Ac Voltage Supply

    The peak value of the starting current depends on the input voltage and the impedance of the power supply, and can be up to 50 A for < 1 ms. This will not have a negative impact on device functionality. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 137: Hardware Descriptions

    Pin assignment RS422 Short description Meaning Transmit data - (O) for full-duplex mode Transmit data + (O) for full-duplex mode Receive data + (I) for full-duplex mode Receive data - (I) for full-duplex mode Signal ground SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 138: Cfast

    LED Output (not connected) PC10 Reserved Input/Output (not connected) PC11 Reserved Input/Output (not connected) PC12 Reserved Input/Output (not connected) PC13 Device Power (3.3V) PC14 Device Power (3.3V) PC15 Device GND PC16 Device GND PC17 Card Detect Out SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 139: Displayport

    Output Ground ML_Lane3- DP data 3- Output CONFIG1 CAD Cable Adapter Detect Input CONFIG2 Ground (PullDown) AUX_CH+ Auxiliary channel+ Bidirectional Ground AUX_CH- Auxiliary channel- Bidirectional Hot Plug Detect Input Ground DP_PWR +3.3V (fused) Output SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 140: Ethernet

    + 5 V (fused) Output Data channel USB2 Input / output Data channel USB2 Input / output Ground – Data channel USB3 Input Data channel USB3 Input Ground – Data channel USB3 Output Data channel USB3 Output SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 141: Usb 2.0

    USB 2.0 port Pin no. Short description Meaning USB_P5V_fused (O) + 5 V (fused) for external USB interface USB_D0M (I/O) Data-, USB channel 0 USB_D0P (I/O) Data+, USB channel 0 USB_GND Ground for external USB interface SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 142: Internal Ports

    Ground PERp0 Receiver differential pair, Lane 0 PRSNT2# Hot-plug presence detect PERn0 Receiver differential pair, Lane 0 (not connected) Ground Ground PETp1 Transmitter differential pair, RSVD Reserved Lane1 PETn1 Transmitter differential pair, Ground Lane1 SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 143 Lane2 PETp3 Transmitter differential pair, Ground Lane3 PETn3 Transmitter differential pair, Ground Lane3 Ground PERp3 Receiver differential pair, Lane3 RSVD Reserved PERn3 Receiver differential pair, Lane3 PRSNT2# Hot-plug presence detect Ground Ground RSVD Reserved SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 144: System Resources

    ISA exclusive (CAN) IRQ6 Free IRQ7 Free IRQ8 System CMOS / real-time clock ISA exclusive IRQ9 ACPI-SCI (system control interrupt) IRQ10 Free IRQ11 Free IRQ12 Free IRQ13 Numeric data processor ISA exclusive IRQ14 Free IRQ15 Free SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 145 Graphics Management Engine Interface USB XHCI Controller IRQ17 PCIe-x4 slot on Riser PCI exclusive IRQ18 PCIe-x4 slot on Riser PCI shared LAN2 (I210) IRQ19 LAN3 (I210) (optional) PCI exclusive IRQ20 Free IRQ21 Free IRQ22 Free IRQ23 Free SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 146: I/O Address Areas

    066h select register selection Reserved Scaler watchdog time (Normal/Macro) 94 ms / 2 s (default) 210 ms / 4 s 340 ms / 6 s 460 ms / 8 s 590 ms / 16 s SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 147: Battery Status Register (Read-Only, Address 50Ch)

    NVRAM address register PCI register address: PCI register content: Length of the memory area NVRAM base address regis- NVRAM memory address (default) E300 0000 Address is assigned dynamically 80000 h (depending on device configura- tion) SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 148: Bios Description

    Setup parameters may not be included, depending on your order. The interface of your BIOS Setup can deviate from the figures in this document. You can find a detailed description of the BIOS on the Support website under Entry ID 92189178 (http://support.automation.siemens.com/WW/view/en/92189178). SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 149: Opening The Bios Selection Menu

    Exit selection menu, continue start sequence Boot Manager Specify the boot media from which to start, for example: Hard disk drive • USB device • Device Management Start device manager for UEFI boot media SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 150 Update BIOS from USB memory stick MEBx Intel Management Engine BIOS Extension from Active Management Tech- nology Support (AMT) Available as of Windows 8, if supported by device Only if the hardware supports AMT SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 151: Structure Of The Bios Setup Menu

    ③ Settings, submenus and Information about your device is displayed in the center device-specific information left-hand area; here you can edit settings which are partly in submenus. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 152 Short help texts on the currently selected setup parame- ters are displayed in the center right-hand area. ⑤ Key assignment The key assignment for navigation in the BIOS Setup is found in the footer. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 153: Exit Menu

    Defaults". Save Custom Defaults The currently configured Setup parameters are saved as a custom profile (see also "Load Custom Defaults"). Discard Changes All changes are discarded. See also SIMATIC IPC after-sales information system (http://www.siemens.com/asis) SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 154: Bios Update

    BIOS update Check regularly if updates are available for download to your device. Additional information can be found on the Internet at the following address: After-sales information system for SIMATIC PC/PG (http://www.siemens.com/asis). Noting down and restoring BIOS Setup settings NOTICE Irretrievable loss of data All BIOS Setup settings are deleted after the BIOS update.
  • Page 155: Alarm, Error And System Messages

    The CMOS clock was operated without battery or with a battery that was too weak, during bat- tery change, for example. Check the CMOS clock. Keyboard controller error or no keyboard present Keyboard defective or not connected SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 156: Active Management Technology (Amt)

    SIMATIC IPC with Intel® AMT from it. The following figure shows remote maintenance of SIMATIC IPCs with Intel® AMT, e.g. for troubleshooting a corrupt operating system or incorrect BIOS settings: SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 157: Overview Of Amt

    5. Activate the option "Intel AMT Configuration Screens". 6. Exit the BIOS Setup with <F10> key (Save and Exit). Settings in the MEBx 1. Use the arrow keys to select "MEBx" and confirm with the <Enter> key. 2. Select "MEBx Login". SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 158 5. Switch to the "Intel(R) ME General Settings" submenu and enable access via the network with "Activate Network Access". 6. Confirm the dialogs that appear with "Y". Drivers are automatically installed once with the Windows system start in the subsequent restart. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 159: Resetting The Intel® Amt To The Default Settings And Disabling Amt

    1. You can obtain the address of the AMT server in the command line in Windows using "ipconfig" and in UNIX using "ifconfig". If the AMT server and operating system do not use the same network address, ask your network administrator for the address you have been assigned. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 160: Forcing User Consent

    Available Available Fax and Scan Available Available File Based Write Filter (FBWF) Available Available Fonts Help and Support Engine Available Available Hibernate Once Resume Many (HORM) Available Available Image Mastering API V2 Available Available SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 161 Note the licensing agreements for Windows Embedded Standard 7. Additional information on language selection is available in the section "Setting up the language selection by means of the Multilanguage User Interface (MUI) (Page 100)". SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 162 Technical information 8.8 Functional scope in Windows SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 163: Technical Support

    You can find additional information and support for the products described on the Internet at the following addresses: ● Technical support (https://support.industry.siemens.com) ● Support request form (http://www.siemens.com/automation/support-request) ● After Sales Information System SIMATIC IPC/PG (http://www.siemens.com/asis) ● SIMATIC Documentation Collection (http://www.siemens.com/simatic-tech-doku-portal) ● Your local representative (http://www.automation.siemens.com/mcms/aspa- db/en/Pages/default.aspx)
  • Page 164: Problem Solving

    "chkdsk" is not function- EWF (Enhanced Write Filter) has Deactivate the EWF or use an alternative method to been activated. The "chkdsk" com- "chkdsk". mand is not supported if the EWF has been activated. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 165: Notes On The Use Of Third-Party Modules

    PC. If the error no longer occurs, the third- Signal frequencies or signal • party expansion card was the cause of the fault. Replace levels are not adhered to this expansion card with a Siemens card or contact the card Different connector pin as- • supplier. signments If the PC still crashes, contact your technical support team.
  • Page 166 Technical support A.3 Notes on the use of third-party modules SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 167: Markings And Symbols

    Opening for Kensington lock opening Attention ESD (Electrostatic sensitive Warning of hot surface device) Operator controls Symbol Meaning Symbol Meaning On/off switch, without electrical isola- Eject CD/DVD tion On/off switch, without electrical isola- tion SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 168: Certificates, Approvals And Markings

    Approved for Korea Period) marking for China Test mark of the Underwriters La- Disposal information, observe the boratories local regulations. Interfaces The following table shows symbols relating to ports that may be available on the device. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 169 DVI-D interface Line In LAN interface, not approved for con- Line Out necting WAN or telephone Serial port Microphone input USB port Universal Audio Jack USB 2.0 high-speed port Headphone output USB 3.0 super-speed port SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 170 Markings and symbols B.5 Interfaces SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 171: List Of Abbreviations

    Clock signal for controllers CMOS Complementary Metal Oxide Semiconduc- Complementary metal oxide semiconductors tors Certificate of authentication Microsoft Windows Product Key Certificate of License License authorization Communications Port Term for the serial interface Communication Processor Communication computer SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 172 Escape character Control character Enhanced Write Filter Frequently Asked Questions FAQs FAT 32 File Allocation Table 32-bit 32-bit file allocation table FBWF File Based Write Filter Floppy disk Disk drive, 3.5" Front Side Bus SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 173 Memory card of the format 32 mm x 24.5 mm Multipoint-capable interface for program- ming devices MRAM Magnetoresistive Random Access Memory Non-volatile data memory. Data memory is re- tained without external power supply. MS-DOS Microsoft Disc Operating System MTBF Mean Time Between Failures SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 174 Installation of device in operating facilities with restricted access - for example, a locked switch- gear cabinet Random Access Memory Ring Input Incoming call Read-Only Memory RS 485 Reconciliation Sublayer 485 Bi-directional bus system designed for up to 32 nodes SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 175 Ultra Extended Graphics Array Graphic standard, maximum resolution 1600x1200 pixels. V.24 ITU-T standardized recommendation for data transfer via serial ports Positive supply voltage of integrated circuits Verein deutscher Elektrotechniker (Union of German Electrical Engineers) SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 176 Program monitoring with error detection and alarming. WLAN Wireless LAN LWireless local area network Wake on Local Area Network World Wide Web Execute Disable Capability Hardware implementation Extended Graphics Array Graphic standard, maximum resolution 1024x768 pixels. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 177: Glossary

    Cache High-speed access buffer for interim storage (buffering) of requested data. CE marking Communauté Européene The CE mark confirms compliance of the product with corresponding EC Directives, for example, with the EMC Directive. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 178 The data are stored in a configuration file and enable the operating system to load the correct device drivers and configure the correct device parameters. . If changes are made to the hardware configuration, the user can change entries in the configuration file using the SETUP program. . SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 179 10/100/1000 Mbps. Execute Disable Capability Hardware implementation that prevents mutual memory accesses by programs and applications. It is only effective when all relevant system components, such as processors, operating systems and applications are supported. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 180 Intel Active Management Technology This technology permits the diagnostics, management and remote control of PCs. It is only effective when all relevant system components, such as processors, operating systems and applications are supported. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 181 Legacy Boot Device Conventional drives can be used as USB devices. License key The license key represents the electronic license stamp of a license. Siemens provides the license keys for protected software. License key disk The license key disk contains the authorizations or license keys required to enable protected SIMATIC software.
  • Page 182 Recovery function of the USB stick Contains the tools for configuring hard disks and the Windows operating system. Reset Hardware reset: Reset/restart of the PC using a button/switch. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 183 This design makes SSDs more rugged, provides shorter access times, low energy consumption and rapid data transfer. STEP 7 Programming software for the creation of user programs for SIMATIC S7 controllers. Troubleshooting Error cause, cause analysis, remedy SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 184 Wake on Local area network. This function allows the PC to be started via the LAN interface. Warm restart The restart of a computer after a program was aborted. The operating system is loaded and restarted again. The CTRL+ ALT+ DEL hotkey can be used to initiate a warm restart. SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 185: Index

    Connecting Ethernet interface, 140 Network, 52 EU Declaration of Conformity, 111 Peripherals, 41 EWF (Enhanced Write Filter), 70 Power supply, 51 Protective conductor, 43, 44 Connecting the protective conductor, 44 Creating an image, 109 SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 186 Memory modules, 130 Processor, 130 Monitoring functions, 66 PROFINET, 145 Motherboard, 130 Protective conductor, 43, 63 Mounting Connecting, 43 Device, 36 Protective conductor connection, 63 with latch fasteners, 38 Protective measure Static electricity, 116 SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 187 Setting up partitions, 105 System partition, 98 Windows XP Professional System resources, 144 Data backup, 109 Wiring information, 46 Temperature monitoring, 67 TFT technology, 10 Third-party expansion cards, 165 Touch screen Operation, 61 Trigger register Watchdog, 146 SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...
  • Page 188 Index SIMATIC IPC477E Operating Instructions, 12/2016, A5E37455003-AB...

Table of Contents