Troubleshooting Charts and Error Codes Troubleshooting Charts
Verify "Recorder Configuration" is set to
Record RX only in the Audio Parameters of
the Consolette Configuration.
Apply an on-channel signal at -47dBm,
modulated by a 1kHz tone at 60% rated
system deviation, to the Consolette receiver.
Is there a 1kHz, ~300
mVrms tone at the Recorder
Connector (J23-1)?
Yes
STOP
Figure 7-21. Recorder RX Audio - A
68009482001
No
Is the APX7500 mobile
operating properly?
Yes
Is the RX Codec Adjustment
in the Consolette Configuration
properly tuned?
Yes
Is there a 1kHz,
~300mVrms tone at U1813-
6 on the Consolette
Mainboard?
Yes
Is there a 1kHz,
~300mVrms tone at
R2834?
Yes
~300mVrms tone present
Refer to the APX7500
Detailed Service
No
Manual for correct
operation and
troubleshooting.
Refer to the "Receive
–
No
Audio Tuning
RX_AUDIO" section of
the manual.
No
Reprogram/Replace Consolette
Mainboard.
Verify R1896, U1813,
No
C1855, R1894, R1893,
C1885, Q1806 & C1856 are
placed properly.
Is ~3.3Vdc
present at
U1813-2?
Yes
Does U1813-1
measure ~2.8Vdc?
Yes
Replace U1813.
There may be an issue with the
No
internal board routing of
VCC_3.3V.
Reprogram/Replace Consolette
No
Mainboard.
September 9, 2011