GE B90 Instruction Manual page 334

Low impedance bus differential system
Hide thumbs Also See for B90:
Table of Contents

Advertisement

INPUTS/OUTPUTS
Program the Latching Outputs by making the following changes in the
OUTPUTS  CONTACT OUTPUT H1a
OUTPUT H1a OPERATE
OUTPUT H1a RESET
Program the pushbuttons by making the following changes in the
 USER PUSHBUTTON 1
PUSHBUTTON 1 FUNCTION
PUSHBTN 1 DROP-OUT TIME
PUSHBUTTON 2 FUNCTION
PUSHBTN 2 DROP-OUT TIME
Application example 2
A relay, having two latching contacts H1a and H1c, is to be programmed. The H1a contact is to be a Type-a contact, while
the H1c contact is to be a Type-b contact (Type-a means closed after exercising the operate input; Type-b means closed
after exercising the reset input). The relay is to be controlled from virtual outputs: VO1 to operate and VO2 to reset.
Program the Latching Outputs by making the following changes in the
OUTPUTS  CONTACT OUTPUT H1a
OUTPUT H1a OPERATE
OUTPUT H1a RESET
OUTPUT H1c OPERATE
OUTPUT H1c RESET
Since the two physical contacts in this example are mechanically separated and have individual control inputs, they do not
operate at exactly the same time. A discrepancy in the range of a fraction of a maximum operating time can occur.
5
Therefore, a pair of contacts programmed to be a multi-contact relay do not guarantee any specific sequence of operation
(such as make before break). If required, the sequence of operation must be programmed explicitly by delaying some of the
control inputs as shown in the next application example.
Application example 3
A make before break functionality must be added to the preceding example. An overlap of 20 ms is required to implement
this functionality.
Write the following FlexLogic equation (EnerVista example shown).
Set both timers (Timer 1 and Timer 2) to 20 ms pickup and 0 ms dropout.
Program the Latching Outputs by making the following changes in the
OUTPUTS  CONTACT OUTPUT H1a
OUTPUT H1a OPERATE
OUTPUT H1a RESET
OUTPUT H1c OPERATE
OUTPUT H1c RESET
5-178
menu (assuming an H4L module):
:
"PUSHBUTTON 1
ON"
:
"PUSHBUTTON 2
ON"
and
menus:
USER PUSHBUTTON 2
: "Self-reset"
: "0.00 s"
: "Self-reset"
: "0.00 s"
and
CONTACT OUTPUT H1c
: "VO1"
: "VO2"
: "VO2"
: "VO1"
and
CONTACT OUTPUT H1c
: "VO1"
: "VO4"
: "VO2"
: "VO3"
SETTINGS  INPUTS/OUTPUTS  CONTACT
PRODUCT SETUP  USER-PROGRAMMABLE PUSHBUTTONS
SETTINGS  INPUTS/OUTPUTS  CONTACT
menus (assuming an H4L module):
SETTINGS  INPUTS/OUTPUTS  CONTACT
menus (assuming an H4L module):
B90 LOW IMPEDANCE BUS DIFFERENTIAL SYSTEM – INSTRUCTION MANUAL
CHAPTER 5: SETTINGS