Specifications
Environmental specifications
Specification
Temperature range
2
Operating
Nonoperating
Relative humidity (noncondensing)
Operating
Nonoperating
1
All temperature ratings shown are for sea level. An altitude derating of 1.0°C per 304.8 m (1.8°F per 1000 ft)
to 3048 m (10,000 ft) is applicable. No direct sunlight allowed. Maximum rate of change is 20°C per hour
(36°F per hour). The upper limit and rate of change might be limited by the type and number of options
installed.
2
System performance during standard operation might degrade if there is a fan fault or if the internal server
temperature is above 30°C (86°F).
Server specifications
Dimension
Height
Depth
Width
Weight (approximate values)
Minimum (one drive and one DIMM installed, no media
drive or expansion board installed)
Maximum (four drives, two DIMMs, optical drive or
SSD, and two expansion boards installed)
Power supply specifications
The server is configured with a non-hot-plug, nonredundant 200 W power supply.
1
Value
—
10°C to 35°C (50°F to 95°F)
-30°C to 60°C (-22°F to 140°F)
—
10% to 90%
28°C (82.4°F) maximum web bulb temperature
(noncondensing) across the operating temperature
range of 0°C to 40°C.
5% to 95%
38.7°C (101.7°F), maximum wet bulb temperature
Value
23.50 cm (9.25 in)
25.40 cm (10.00 in)
23.00 cm (9.06 in)
6.495 kg (14.32 lb)
9.69 kg (21.36 lb)