PREPARATION BEFORE OPERATION
Remote controller
How to set the batteries and the current
1
time
Remove the front lid and insert batteries.
Then reattach the front lid.
Insert the minus pole of the batteries first.
Check if the polarity of the batteries is correct.
Insert the minus pole
2
of the batteries first.
Press the RESET button.
Press here using
a thin stick.
• If the RESET button is not pressed, the remote con-
3
troller may not operate correctly.
Press the CLOCK set button.
Press here using
a thin stick.
4
HR.
MIN.
Press the
and
buttons (TIME SET
buttons) to set the current time.
FAN
STOP
I FEEL COOL
VANE
START
HEAT
DRY
MODE
HR.
ECONO COOL
LONG
MIN.
RESET CLOCK
HR.
• Each time the
button is pressed, the set time is
MIN.
counted up by 1 hour, and each time the
5
is pressed, the set time is counted up by 1 minute.
Press the CLOCK set button again and close
the front lid.
VN79C550H01_EN
5
Handling of the remote controller
• The range that the signal can reach is about 6 m when
the remote controller is pointed at the front of the in-
door unit.
• When a button is pressed, one or two beeps will be
heard from the indoor unit. If no sound is heard, op-
erate again.
• Use the remote controller carefully.
If it is dropped, thrown or it gets wet, the remote con-
troller may not operate.
• Since the display on the remote controller is made of
liquid crystal (glass),it may not light up if it is damaged
from falling.
• Refer to page 10 when the indoor unit does not
respond to the remote control signal.
When installing on a wall, etc.
• Install the remote controller holder in a position where
the signal reception sound (beep) can be heard from
ON/OFF
the indoor unit when the
button is pressed.
How to install/remove the remote controller
Installing :Insert the remote controller downward.
Removing :Pull it up.
Remote control-
ler holder
Dry-cell batteries
I Reference for replacing batteries
Replace the batteries with new AAA alkaline batteries
in the following cases:
·
When the indoor unit does not respond to the remote
control signal.
·
When the display on the remote controller becomes dim.
·
When a button of the remote controller is pressed, all
displays appear on the screen, and then disappear
immediately.
Do not use manganese batteries. The remote controller
could malfunction.
• The service life of an alkaline battery is about 1 year.
However, a battery whose time limit is approaching
may be exhausted soon. The recommended usable
time limit is indicated (month/year) on the bottom of
the battery.
• To prevent liquid leakage, take out all batteries when
the remote controller is not going to be used for a
long time.
button
CAUTION:
If liquid from the batteries gets onto your skin or clothes,
wash it well with clean water.
If liquid from the batteries gets into your eyes, wash
them well with clean water and consult a doctor at once.
• Do not use rechargeable batteries.
• Replace the 2 batteries with new ones of the same type.
• Dispose of exhausted batteries in the correct manner.
When the remote controller cannot be used (emergency operation)
When the batteries of the remote controller run out or the remote controller malfunctions, the emergency operation
1
can be done using the EMERGENCY OPERATION switch.
Press the EMERGENCY OPERATION switch.
• Each time the EMERGENCY OPERATION switch is
pressed, the unit will operate in order of EMER-
GENCY COOL MODE, EMERGENCY HEAT MODE
and STOP MODE.
However, when the EMERGENCY OPERATION
switch is once pressed, the unit will operate in test
run for 30 minutes and then the operation mode
shifts to EMERGENCY MODE.
Details of EMERGENCY MODE are as shown below.
However, the temperature control does not work for 30
minutes in test run and the unit is set to continuous
operation. The fan speed is set to High in test run and
shifts to Medium after 30 minutes.
Operation mode
COOL
HEAT
Set temperature
24°C
24°C
Fan speed
Medium
Medium
Horizontal vane
Auto
Auto
The operation mode is indicated by the Operation
Indicator lamp on the indoor unit as following figure.
Operation Indicator lamp
EMERGENCY COOL
EMERGENCY HEAT
STOP
Operation Indicator
Operation Indicator
Operation Indicator
18/10/2004, 5:16 PM
2
To stop the emergency operation, press the
EMERGENCY OPERATION switch once (in
case of EMERGENCY HEAT MODE) or twice
(in case of EMERGENCY COOL MODE).