6. Electrical work
Function table
Select unit number 00
Mode
Power failure automatic recovery
Indoor temperature detecting
LOSSNAY connectivity
Power voltage
Select unit numbers 01 to 03 or all units (AL [wired remote controller]/07 [wireless remote controller])
Mode
Filter sign
Fan speed
No. of air outlets
Installed options (high-performance fi lter)
Up/down vane setting
*1 When the power supply returns, the air conditioner will start 3 minutes later.
*2 Power failure automatic recovery initial setting depends on the connecting outdoor unit.
6.3.3 How to set the fi xed up/down air direction
(Only for wired remote controller and PUHZ, PU(H) application)
• Only the particular outlet can be fixed to certain direction with the
procedures below. Once fi xed, only the set outlet is fi xed every time air
conditioner is turned on. (Other outlets follow UP/DOWN air direction
setting of the remote controller.)
Explanation of word
• "Refrigerant address No." and "Unit No." are the numbers given to
each air conditioner.
• "Outlet No." is the number given to each outlet of air conditioner.
(Refer to the right.)
• "Up/Down air direction" is the direction (angle) to fi x.
Reset
1
2
horizontal
Settings
Not available
Available
Indoor unit operating average
Set by indoor unit's remote controller
Remote controller's internal sensor
Not Supported
Supported (indoor unit is not equipped with outdoor-air intake)
Supported (indoor unit is equipped with outdoor-air intake)
240 V
220 V, 230 V
Settings
100Hr
2500Hr
No fi lter sign indicator
Silent
Standard
High ceiling
4 directions
3 directions
2 directions
Not supported
Supported
Equipped with vanes (vanes angle setup 3)
Equipped with vanes (vanes angle setup 1)
Equipped with vanes (vanes angle setup 2)
3
4
5
Mode no.
01
*1
02
03
04
Mode no.
07
08
09
10
11
Horizontal airflow
Remote controller setting
The airflow direction of
this outlet is controlled by
the airflow direction setting of
remote contoller.
Outlet No.3
Outlet No.2
Note: "0" indicates all outlets.
Setting no. Initial setting
setting
1
2
Ο
1
Ο
2
3
1
Ο
2
3
1
2
Ο
Setting no. Initial setting
setting
1
2
Ο
3
1
2
Ο
3
1
Ο
2
3
1
Ο
2
1
2
3
Ο
Downward
Fixed setting
The airflow direction of
this outlet is fixed
in particular direction.
When it is cold because of direct airflow,
the airflow direction can be fixed
horizontally to avoid direct airflow.
Outlet No.4
MITSUBISHI
ELECTRIC
label
Outlet No.1
11