Installation Location; Installing The Indoor Unit - Mitsubishi Electric PKA-RP-KAL Installation Manual

Hide thumbs Also See for PKA-RP-KAL:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1

2. Installation location

PKA-RP60, 71, 100KAL
B
L
M
F
G
Fig. 2-1

3. Installing the indoor unit

1
2
4
5
7
8
0
Fig. 3-1
PKA-RP60, 71, 100KAL
F
H
15.5
0
25
50
75
100
117
125
142
192
242
279.5
292
C
A
K
Fig. 3-2
B
A
C
E
D
Fig. 3-3
A
(mm)
1170
C K
D
E
*
H
3
6
9
G
A
E
100m
I
J
A
Sleeve
B
Hole
C
(Indoors)
D
Wall
E
(Outdoors)
2.1. Outline dimensions (Indoor unit) (Fig. 2-1)
Select a proper position allowing the following clearances for installation and
maintenance.
PKA-RP60, 71, 100KAL
A
Min. 100.5
Min. 52.3
F
Air outlet: Do not place an obstacle within 1500 mm of the air outlet.
G
Floor surface
H
Furnishing
I
When the projection dimension of a curtain rail or the like from the wall exceeds 60 mm,
J
extra distance should be taken because the fan air current may create a short cycle.
I
J
1800 mm or greater from the floor surface (for high location mounting)
K
108 mm or greater with left or rear left piping and optional drain pump installation
L
550 mm or greater with optional drain pump installation
M
Minimum 7 mm: 265 mm or greater with optional drain pump installation
3.1. Check the indoor unit accessories (Fig. 3-1)
The indoor unit should be supplied with the following accessories.
PART NUMBER
1
Mount board
Tapping screw 4 × 25
2
3
Felt tape
4
L-shaped connection pipe
5
Charge nut
6
Wireless remote controller
7
Remote controller holder
8
Alkali batteries (size AAA)
9
Tapping screw 3.5 × 16
0
Spacer
3.2. Installing the wall mounting fixture (Fig. 3-2)
3.2.1. Setting the wall mounting fixture and piping positions
► Using the wall mounting fixture, determine the unit's installation position
(mm)
and the locations of the piping holes to be drilled.
Warning:
B
Before drilling a hole in the wall, you must consult the building contractor.
54
25
0
PKA-RP60, 71, 100KAL
12.5
37.5
A
1
62.5
Mount board
87.5
B
104.5
Indoor unit
129.5
C
Bottom left rear pipe hole (ø75-ø80)
167
D
217
Bottom right rear pipe hole (ø75-ø80)
229.5
E
264
Knockout hole for left rear hole (75 × 480)
292
F
308.5
Bolt hole (4-ø9 hole)
311
G
Center measurement hole (ø2.5 hole)
D
H
Tapping hole (75-ø5.1 hole)
I
Hole centre
J
Align the scale with the line.
K
Insert scale.
3.2.2. Drilling the piping hole (Fig. 3-3)
► Use a core drill to make a hole of 75-80 mm diameter in the wall in the
piping direction, at the position shown in the diagram to the left.
► The hole should incline so that the outside opening is lower than the
inside opening.
► Insert a sleeve (with a 75 mm diameter and purchased locally) through the
hole.
Note:
The purpose of the hole's inclination is to promote drain flow.
B
C
D
Min. 48
Min. 250
QUANTITY
ACCESSORY
60, 71, 100
1
7
2
1
1
1
1
2
2
1
(mm)
E
Min. 220
LOCATION OF
SETTING
Fix at the back of the
unit
Make use of
packaging material
3