3. Operation

■ About the operation method, refer to the operation manual that comes with each remote controller.
3.1. Turning ON/OFF
3.1.1. For wired remote controller
[ON]
Press the [ON/OFF] button.
The ON/OFF lamp will light up in green,
and the operation will start.
■ Operation status memory
Operation mode
Operation mode before the power was turned off
Preset temperature
Preset temperature before the power was turned off
Fan speed
Fan speed before the power was turned off
3.1.2. For wireless remote controller
[ON]
■ Press the ON/OFF button ① .
Note:
● When the unit is restarted, initial settings are as follows.
Remote Controller settings
Mode
Last operation mode
Temperature setting
Last set temperature
Fan speed
Last set fan speed
Airflow up/down
Mode
[OFF]
■ Press the ON/OFF button ① again.
Note:
Even if you press the ON/OFF button immediately after shutting down the operation is progress, the air conditioner will not start for about three minutes.
This is to prevent the internal components from being damaged.
3.2. Mode select
3.2.1. For wired remote controller
Press the [F1] button to go through the
Fri
operation modes in the order of "Cool",
"Dry", "Fan", "Auto", and "Heat". Select the
Room
Cool
Set temp.
desired operation mode.
Mode
Temp.
Fan
F1
F2
F3
F4
• Operation modes that are not available to
the connected indoor unit models will not
appear on the display.
What the blinking mode icon means
The mode icon will blink when other indoor units in the same refrigerant
system (connected to the same outdoor unit) are already operated in a
different mode. In this case, the rest of the unit in the same group can
only be operated in the same mode.
Remote controller setting
COOL or DRY
Horiz. outlet
HEAT
Last setting
FAN
Horiz. outlet
Cool
Dry
Fan
Auto
Heat
[OFF]
Press the [ON/OFF] button again.
The ON/OFF lamp will come off, and
the operation will stop.
■ Settable preset temperature range
Operation mode
Preset temperature range
Cool/Dry
19 – 30 °C
Heat
17 – 28 °C
Auto
19 – 28 °C
Fan/Ventilation
Not settable
2
ON/OFF
FAN
MODE
VANE
CHECK
LOUVER
TEST RUN
SET
RESET
(option)
AAA
AAA
3.2.2. For wireless remote controller
■ Press the operation mode (
operation mode 2.
Cooling mode
Drying mode
Fan mode
Heating mode
Automatic (cooling/heating) mode
Ventillation mode
Only indicated on the following condition
Wired remote controller used
LOSSNAY connected
3
4
TEMP
AUTO STOP
AUTO START
h
min
CLOCK
) button ② and select the
7