Single T9800 Tank Loading Installation - Bosch Greentherm T9800 SEC 160/199 Applications Manual

Indoor residential and commercial tankless water heaters
Table of Contents

Advertisement

1 4 | Greentherm T9800 SE(C) 160/199

4.4.1 Single T9800 tank loading installation

Local code requirements
may require installation
Hot
of a thermostatic mixing
Water
valve in some
Supply
installations.
Storage Tank
Legend
Full-port
ball valve
Union
Potable
expansion
tank
1) as required by local code.
Recommended Pump:
Manufacturer
Grundfos
Taco
B & G
Table 7
DISCLAIMER: This drawing is conceptual in nature, not to scale and for reference only. Additional functional, installation, and safety devices may be needed or
required. All work pertaining to the installation shall be in full compliance with all legal requirements, including national and local codes. Best installation practices
should be followed.
Data subject to change
External NTC sensor
(part# 7 736 504 583)
Thermostatic
mixing valve
Check valve
Pressure
relief valve
Model
UP 26-99 SF
0013 SF3
PL-36
see wiring detail
Section 4.4, page 13
Gas
Cold Water
Supply
Y-type strainer
Aquastat or Thermistor
Circulator
Application Manual
NBT-23
Condensate
)
Neutralizer 1
(part# 7 738 005 514)
To drain or
pump
06.2017 | Bosch Thermotechnology Corp.