ELMETRON CP-411 User Manual

ELMETRON CP-411 User Manual

Waterproof ph-meter
Hide thumbs Also See for CP-411:

Advertisement

Quick Links

WATERPROOF
pH-METER
CP-411
USERS MANUAL
Sp. j.
41-814 Zabrze, ul. Witosa 10, POLAND
tel. +48 32 / 273 8106, tel./fax +48 32 / 2738114
www.elmetron.com.pl
e-mail: info@elmetron.com.pl

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CP-411 and is the answer not in the manual?

Questions and answers

Summary of Contents for ELMETRON CP-411

  • Page 1 WATERPROOF pH-METER CP-411 USERS MANUAL Sp. j. 41-814 Zabrze, ul. Witosa 10, POLAND tel. +48 32 / 273 8106, tel./fax +48 32 / 2738114 www.elmetron.com.pl e-mail: info@elmetron.com.pl...
  • Page 2 WATERPROOF pH-METER CP-411 USERS MANUAL Before use, please read this instruction carefully!  Users manual CP-411 pH meter...
  • Page 3 W A R R A N T Y The “ELMETRON” company gives 24 months of warranty CP-411 pH-meter number......... In case of damage the producer will repair the meter within 14 days from the day of delivery. The warranty doesn’t cover the damages caused by...
  • Page 4: Table Of Contents

    CONTENTS 1. Exploitation notices 2. The characteristics of the pH-meter CP-411 3. What is the meter designed for? 4. Outside view 5. Switching the meter ON and OFF 6. Preparation to work 7. Preparation of the pH electrode 8. Calibration of the pH electrode 8.1 Calibration with automatic temperature compens.
  • Page 5: Exploitation Notices

    The essential feature of our products is their low failure frequency. However if your pH-meter will fail, our firm immediately performs its warranty repair. We wish to you a pleasant and trouble-free work with our meter.  Users manual CP-411 pH meter...
  • Page 6: The Characteristics Of The Ph-Meter Cp-411

    - 3 - - 20 - 2. THE CHARACTERISTICS OF THE pH-METER CP-411 15. TECHNICAL DATA The CP-411 pH-meter belongs to the newest generation of FUNCTION: temperature measuring devices with high accuracy and repeatability of - 50.0 ÷ 199.9 o C RANGE: 0.00 ÷...
  • Page 7: What Is The Meter Designed For

    In dependence on the be changed. To do this it is necessary to unscrew the two kind of used pH electrode the CP-411 may measure clean screws in the lower wall of the meter pull out the whole wall water, sewage, soil, milk, meat, cheese, etc.
  • Page 8: Outside View

    1. F - BNC-50 connector for connecting the combination pH electrode or Redox electrode; 2. t - Chinch input for connecting the temperature probe; 3. pin input for connecting a reference electrode; 4. P - Power adapter input 9V.  Users manual CP-411 pH meter...
  • Page 9: Technical Data

    Small differences of the results are connected with the accuracy of the meter. The accuracy of CP-411 is ±0,01 pH, ±1 digit, what practically means that in extreme conditions results of two measurements of this same solution may differ ±0,05 pH and this will be an acceptable error.
  • Page 10 In case of working on the batteries to save them the meter switches it self automatically off after 10 minutes from the last pressing of any button. This function is switched off for the time of calibration or working with the power adapter.  Users manual CP-411 pH meter...
  • Page 11 Before starting the work one should : MEASUREMENTS RESULTS join the power adapter plug to the right input (P) if work The CP-411 pH meter has an automatic temperature with the power adapter is planned; compensation, which enables eliminating errors which result...
  • Page 12 (usually as the electrolyte a KCl solution is used).  Users manual CP-411 pH meter...
  • Page 13 CP-411 enables calibration in buffer solutions with values electrode to the right connectors on the meter (pic.1); determined by the manufacturer, this value is automatically if the electrode wasn’t calibrated or was already used...
  • Page 14 7.00 and 9.00 buffers is advised. buffer and acting according to the point b. In CP-411 characteristic of the electrode is approximated segmentaly between the calibration points. If after entering the calibration mode one will exit it...