Warning
Fire hazard Incorrect fuses overload the electrical system.
Only use fuses with the required ampere value.
Do not bypass or repair fuses.
Info
The main fuse protects all power consumers of the vehicle.
Recharge the battery.
Guideline
Maximum charging voltage
Maximum charging current
Maximum charging time
Charge the battery regularly when
the motorcycle is not in use
Ideal charging and storage tem-
perature of the lithium-ion battery
Connect the battery charger to the battery. Switch on the battery charger.
Battery charger (81229074000)
The charging time may be longer at low temperatures.
This battery charger is not suitable for the trickle charging of lithium-ion batteries.
Switch off the battery charger after charging and disconnect from the battery.
Finishing work
Install the battery.
Mount the seat. (
Install the air filter box cover. (
Preparatory work
Switch off all power consumers and switch off the engine.
Remove the air filter box cover. (
Remove the seat. (
Main work
Pull starter relay
S01345-10
Info
If the charging current, charging voltage, or charging time are
exceeded, the battery will be destroyed.
If the battery is left in a discharged state for an extended period, it
will become over-discharged and sulfated, destroying the battery.
The battery is maintenance-free.
Never remove cover
.
(
p. 87)
p. 55)
p. 56)
p. 55)
p. 54)
from the holder.
14.4 V
3.0 A
12 h
6 months
10... 20 °C (50... 68 °F)
89