Performance Data Sheet - KitchenAid P9WB2L Use & Care Manual

French door bottom mount refrigerator
Table of Contents

Advertisement

Available languages

Available languages

Water Filtration System
Model
P9WB2L/P9RFWB2L
Capacity
200 Gallons
(757 Liters)
System
tested and certified
by NSF International
against
NSF/ANSI
Standard
42, Standard
53, and Standard
401 for
the reduction
of contaminants
specified
on the Performance
Data Sheet.
This system has been tested according to NSF/ANSI Standards
42, 53 and 401 for the reduction of the substances
listed below. The concentration
of the indicated substances
in water entering the system was reduced to a concentration
less than or equal to the permissible limit for water leaving
the system, as specified
in NSF/ANSI Standards 42, 53, and 401.
Substance
Reduction Aesthetic
Effects
Influent Challenge
Concentration
Chlorine Taste/Odor
Particulate Class I*
Contaminant
Reduction
Lead: @ pH 6.5 / @ pH 8.5
Benzene
p-Dichlorobenzene
Carbofuran
Toxaphene
Atrazine
Asbestos
Live Cysts T
Turbidity
Lindane
Tetrachloroethylene
O-Dichlorobenzene
Ethylbenzene
1,2,4-Trichlorobenzene
2,4 - D
Styrene
Toluene
Endrin
Atenolol
Trimethoprim
Linuron
Estrone
Nonylphenol
2.0 mg/L _+10%
At least 10,000 particles/mL
Influent Challenge
Concentration
0.15 mg/L+ 10%
0.015 mg/L_+ 10%
0.225 mg/L_+ 10%
0.08 mg/L _+10%
0.015 _+10%
0.009 mg/L _+10%
107to
108fibers/L tt
50,000/L min.
11 NTU _+10%
0.002 _+10%
0.015 mg/L_+ 10%
1.8 mg/L_+ 10%
2.1 mg/L_+ 10%
0.210 mg/L_+ 10%
0.210 mg/L_+ 10%
2.0 mg/L_+ 10%
3.0 mg/L _+10%
0.006 mg/L _+10%
200 _+20%
140 _+20%
140 _+20%
140 _+20%
1400 _+ 20%
Test Parameters: pH = 7.5 + 0.5 unless otherwise
noted. Flow = 0.75 gpm (2.84
22°C). Rated service capacity = 200 gallons (757 liters).
Maximum
Permissible
Product Water Concentration
50% reduction
85% reduction
Maximum
Permissible
Product Water Concentration
0.010 mg/L
0.005 mg/L
0.075 mg/L
0.040 mg/L
0.003 mg/L
0.003 mg/L
99%
99.95%
0.5 NTU
0.0002 mg/L
0.005 mg/L
0.60 mg/L
0.70 mg/L
0.07 mg/L
0.07 mg/L
0.1 mg/L
1.0 mg/L
0.002 mg/L
30 ng/L
20 ng/L
20 ng/L
20 ng/L
200 ng/L
Lpm). Pressure = 60 psig (413.7 kPa). Temp. =
Average% Reduction
97.0%
>99.9%
Average%
Reduction
>99.3%
/ 98.6%
93.8%
99.8%
81.9%
>95%
87.0%
>99%
>99.99%
96.9%
>99.2%
96.6%
92.3%
86.9%
>99.8%
88.5%
99.6%
93.5%
81.7%
95.7%
96.1%
96.3%
95.3%
95.5%
68°F to 71.6°F
(20°C to
The compounds
certified under NSF 401 have been deemed as "emerging compounds/incidental
contaminants."
Emerging compounds/incidental
contaminants
are those compounds
that have been detected in drinking water supplies at trace levels. While occurring at only trace levels, these
compounds
can affect the public acceptance/perception
of drinking water quality.
It is important that operational,
maintenance,
and filter replacement
requirements
be carried out for the product to perform as advertised.
Property damage can occur if all instructions
are not followed.
The disposable
cartridge must be changed at least every 6 months.
Use replacement
filter P9RFWB2L, part #EDR2RXD1/EDR2RXD1B.
2015 suggested
retail price of $49.99 U.S.A./S49.99
Canada. Prices
are subject to change without notice.
The filter monitor system measures the amount of water that passes
through the filter and alerts you when it is time to replace the filter.
Refer to the "Using the Controls"
or "Water Filtration System" section
(in the User Instructions
or User Guide) to learn how to check the
water filter status.
After changing the water filter, flush the water system. See "Water
and Ice Dispensers"
or "Water Dispenser"
in the User Instructions or
User Guide.
These contaminants
are not necessarily in your water supply. While
testing was performed under standard laboratory conditions,
actual
performance
may vary.
The product
is for cold water use only.
The water system must be installed in compliance
with state and
local laws and regulations.
Do not use with water that is microbiologically
unsafe or of unknown
quality without adequate disinfection
before or after the system.
Systems certified for cyst reduction may be used on disinfected
waters that may contain filterable cysts.
EPA Est. No. 082047-TWN-001
Refer to the "Warranty"
section (in the User Instructions
or User
Guide) for the Manufacturer's
limited warranty, name and telephone
number.
Application
Guidelines/Water
Supply Parameters
Water Supply
City or Well
Water Pressure
30 - 120 psi (207 - 827 kPa)
Water Temperature
33 ° - 100°F (0.6 ° - 37.8°C)
Service Flow Rate
0.75 gpm (2.84 L!min.) @ 60 psi
*Class I particle size: >0.5 to <1 um
tBased on the use of Cryptosporidium
parvum oocysts
ttFibers greater than 10 um in length
® NSF is a registered trademark
of NSF International.
38

Advertisement

Table of Contents
loading

This manual is also suitable for:

P9rfwb2l

Table of Contents