Norton 6900 PowerMatic Installation Instructions Manual

Low energy power operator

Advertisement

80-9369-0120-020 (09-08 )
Standard Duty Double Lever Arm Application for Frame Reveals to 6-7/8" (175mm)
Stop (Push) Side of Door Installation For Handed (Not Reversible) Units
Door Openings 85° to 110° Use Series 6920 / 6921
Door Openings 111° to 180° Use Series 6930 / 6931
Left Hand Door
Activation Modes (Modes are configured during installation.)
• Selectively Activated Mode -
switches or scanners for activation of functions.
• Automatically Activated Mode -
movement of the door toward the open position
ELS switching that automatically activates the functions. External
switches or scanners may also be used for activation.
Functions (Functions are configured during installation.)
• Power Operator function (POR)
energy power door operator. Field settings allow for following two

functions:

1. Selectively Activated Mode (See Above).
2. Automatically Activated Mode (See Above).
• Power Assist function (PAS)
door closer unless activated via one of the Modes listed above.
Upon activation the door opening resistance is reduced, for a
selected period of time, well below A.D.A. guidelines. When the
time period expires, the door closes under normal door closer
spring power.
NOTE: The
ELS Board Dip Switches
Selectively Activated Mode
20 VOLT POTENTIAL PRESENT. MAKE SURE
POWER IS TURNED OFF DURING
INSTALLATION PROCEDURE.
Basic Requirements
Parts Identification
Installation Template
Installation Sequence
Regulation & Adjustment
80-9369-0120-020 (09-08)
unit depends upon external
unit will operate
with a slight
utilizing on-board
– The unit performs as a low
– The unit operates as a standard
are factory set in the
as a
Power Operator Function.
ARNING
®
6900 PowerMatic
Installation Instructions
Right Hand Door
AmericansWith Disabilities Act (A.D.A.)
These door operators can be installed and adjusted to conform with
A.D.A. regulations.
ANSI Standards
ANSI A117.1
assemblies to conform to the requirements of this
specification "for buildings and facilities –
accessibility and usability for physically
handicapped people"
• ANSI A156.19
– These products are designed to conform to this
specification
"for power assist and low energy power
operated doors"
.
– "PAS" Function is designed to meet or exceed all of the
Requirements for the "Power Assist Door".
– "POR" Function is designed to meet or exceed all of the
requirements for the "Low Energy Power Operated Door".
U.L. Listing
Underwriters Laboratories, Inc. listed for use on
U L
C
US
fire and smoke barrier door assemblies when the
®
120VAC (60Hz) power input is supplied through
the normally closed alarm contacts of a
compatible U.L. Listed alarm system or alarm
panel.
An incorrectly installed or improperly
adjusted door operator can cause property
damage or personal injury. These
instructions should be followed to avoid the
possibility of misapplication or
2
2
3
ELS "Timing" Calibration
4
5
Low Energy Power Operator
– These door operators permit door
.
misadjustment.
providing
6
6
7
8
8

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 6900 PowerMatic and is the answer not in the manual?

Questions and answers

Scott
January 26, 2025

is there a parts manual for the norton 6900 powermatic

1 comments:
Mr. Anderson
February 10, 2025

The provided context does not mention a specific parts manual for the Norton 6900 PowerMatic. However, it does include a "Parts Identification" section, which may contain relevant details.

This answer is automatically generated

Summary of Contents for Norton 6900 PowerMatic

  • Page 1 ® 6900 PowerMatic Low Energy Power Operator Installation Instructions 80-9369-0120-020 (09-08 ) Standard Duty Double Lever Arm Application for Frame Reveals to 6-7/8” (175mm) Stop (Push) Side of Door Installation For Handed (Not Reversible) Units Door Openings 85° to 110° Use Series 6920 / 6921 Door Openings 111°...
  • Page 2 Requirements • U.L. labeled fire or smoke barrier door assemblies require that • Minimum suggested and required material thickness for hollow the 120VAC (60Hz) power input to the PowerMatic™ door metal frames (skin plus reinforcement) is charted on page 3. operator be supplied through normally closed alarm contacts of •...
  • Page 3 DETERMINE HAND OF DOOR Hollow Metal Door Frame Reinforcing Reinforcing Frame Material Recommended Min. Required Left Right 12 Ga. 12 Ga. 18 Ga. Hand Hand .1046 .1046 .0478 Door Door (2.66) (2.66) (1.21) 14 Ga. 10 Ga. 12 Ga. .0747 .1343 .1046 (1.90)
  • Page 4 nstallation Sequence • Install and tighten 1/4-20 Flange Head Screw with 7/16” • Determine hand of door from illustration on Page 3. wrench or socket. • Using template, locate and prepare holes in the frame and door: Arm Mark Pinion Frame Flat –...
  • Page 5 Adjustments for the PowerMatic Product TEACHING CLOSED AND OPEN DOOR POSITIONS: The following adjustments mechanical, hydraulic and electrical are Before operating, the PowerMatic 6900 must be “taught” the listed in a suggested sequence. fully closed and fully open door positions. NOTE: Make sure that power to unit is •...
  • Page 6 General Product Information (See illustrations on page 2 for location of switch and valves.) – Power Operator Funtion Only (POR). • Selector Mode Switch – This is a three (3) position switch that has positions marked "OFF” “ON” “H/O". Adjusts the opening speed of the door. –...
  • Page 7 ELS Board Timing Instructions: LH-PUSH UNITS: • Rotate the ELS Board Pulley Clockwise unit hard stop is reached. • Depress and hold Black Button on the ELS Board. While WARNING: Make sure dip switch #3 on ELS Board depressing button, turn power input to unit “ON” and continue is in the “A”...
  • Page 8 Adjust Obstruction Sensitivity to a longer time setting. See page 7. ASSA ABLOY 3000 Highway 74 East • Monroe, NC 28112 Norton ® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company. Tel: (877)-974-2255 • Fax: (800)-338-0965 Copyright ©...

Table of Contents

Save PDF