Setting the DP-110
Connector installation screw
Inch-type hexagonal lock screws are installed in the connector for serial cable connection of DP-110. 
If millimeter-type lock screws are needed, use the millimeter-type lock screws of the accessory.
Notch (one or more lines)
inch-type

Jumper setting

Set the jumpers as follows:
JP1
JP2
1-2
1-2
2-3
2-3
millimeter-type
For connecting both the TM printer and the DP-110. (Default setting)
Set this when using a standalone connection.
Installation screw