Fans

The FT5000 server contains five removable chassis fans (and can accept up to three more) to cool
the boards and removable media drives. These chassis fans connect to the front panel board and
are enclosed in a removable foam assembly. The integrated power supply fan(s) provides more
cooling and airflow.
Removing the system fan assembly
1.
Observe the precautions as given in Safety & Regulatory Notices at the front of this
handbook.
2.
Remove the access cover as previously detailed.
3.
Remove the foam cover from the front subchassis by pulling it straight out as above. For
better access to the individual fan cables on the front panel board, carefully rotate the right
edge of the foam fan assembly outward into the opening where the foam cover was.
4.
Label and disconnect the individual fan cables from the front panel board. For fan cabling
considerations, see page.
5.
Remove the fan assembly from the chassis.
Removing an individual system fan
N N O O T T E E
Correct airflow direction: The side of each fan is embossed with directional arrows indicating
airflow direction. Always note the direction of the arrows on a fan before removing it. Contact
your Mitsubishi dealer for suitable replacement fans.
1.
Observe the precautions as given in Safety & Regulatory Notices at the front of this
handbook.
2.
Remove the access cover as previously detailed.
W o r k i n g i n s i d e t h e s y s t e m
FT5000 HANDBOOK
2/7