PROMPTS
Trip Inputs 1or2
30
w/Bell Out (N)_
Telco Zone
31
(0)_
Open/Close Zone
32
(0)_
Zn1 Trigger Type
33
(V+)_
Invert Zn1 Y/N
34
(N)_
Restore Zn1 Y/N
35
(Y)_
Delay Zn1 (secs)
36
(00)_
Rpt Zn1 ONLY if
37
Armed (N)_
Invert Zn2 Y/N
38
(N)_
4204/
ZONE
ENTRY
2-4204
TRIG.
OPTIONS
[Y], [N]
Use if the zone 1 and 2 connection to the control's
bell output causes a bell fault on the control panel.
NOTES:
1. If used, EOLR trigger type is not available for
zones 1, 2 and 3.
2. Do not use with Lynx controls.
Zone Trig:
See Important Information Regarding Zone Input
[3-7]
Options on previous page.
Enter the zone number to be used for Telco line
4204: [1-4]
fault reports. This zone assignment must be unique
2-4204: [1-8]
from the Open/Close Zone selected in Prompt 35.
Zone Trigger Mode: If any zone is programmed for
[0] = not used
"report only if armed," zone 7 cannot be used. If
Lynx Panic is enabled, zone 3 cannot be used.
4204 Mode: If any zone is programmed for "report
only if armed," zone 4 cannot be used.
2-4204 Mode: If any zone is programmed for "report
only if armed," or if tamper is enabled, zone 8
cannot be used.
NOTE: Connect the Telco line fault output (or relay
output programmed for "Telco line fault") to the
Telco zone.
Zone Trig:
Enter the zone number to be used for open/close
(arm/disarm) reports.
[3-7]
This zone assignment must be unique from the
4204: [1-4]
Telco Zone selected in Prompt 34.
Zone Trigger Mode: If any zone is programmed for
2-4204: [1-8]
"report only if armed," zone 7 cannot be used as an
[0] = not used
open/close zone. If Lynx Panic is enabled, zone 3
cannot be used.
4204 Mode: If any zone is programmed for "report
only if armed," zone 4 cannot be used as an
open/close zone.
2-4204 Mode: If any zone is programmed for "report
only if armed," or if tamper is enabled, zone 8
cannot be used as an open/close zone.
NOTE: Connect an open/close (arm/disarm) trigger
(or relay output) from the control panel to the
open/close zone.
• (EOLR)
Selects the triggering method for this zone input.
• (V+)
Press the [space] key to scroll through choices.
UL: V+ must be set as inverted and V- as non-
• (V–)
inverted
[Y], [N]
Inverts the alarm and normal states of the zone 1
trigger; otherwise uses normal input signal.
[Y], [N]
Enables restore reporting for zone 1.
[01-15]
Defines the reporting delay in seconds for zone 1.
UL: Must be 00
[00]=no delay
[Y], [N]
Report alarms on zone 1 ONLY if the conditional
zone (zone 7 in zone trigger mode; zone 4 in 4204
mode; or zone 8 in 2-4204 mode) is triggered
(armed).
If [N], always reports alarms on zone 1.
Inverts the alarm and normal states of the zone 2
[Y], [N]
trigger; otherwise uses normal input signal.
Section 3: Programming the 7847i-E