Ir Image Management; Maintenance - Fluke 279 FC User Manual

True-rms thermal multimeter
Hide thumbs Also See for 279 FC:
Table of Contents

Advertisement

IR Image Management

You can manage your IR images through SmartView
software installed on your PC. Use SmartView to download
and delete the IR images from the Multimeter.
To download or delete IR images:
®
1.
Open SmartView
on the PC.
2.
Connect a USB 2.0 (High Speed) cable to the Multimeter.
Plug in the large (USB "A") connector of the cable to your
PC and the small (USB "Micro B") connector to the
Multimeter.
3.
With SmartView, choose from the following options:
Download New - download only the new files created
after the previous download.
Download All - download all files.
Download All & Delete - download all files and delete
from the MultiMeter.
Delete All - delete all files on the Multimeter.

Maintenance

®
desktop
To prevent a possible electrical shock, fire, or
personal injury:
Remove the input signals before you clean the
Product.
Use only specified replacement parts.
Have an approved technician repair the
Product.
Disconnect the battery charger and move the
Product or battery to a cool, non-flammable
location if the rechargeable battery becomes
hot (>50 °C) during the charge period.
Replace the rechargeable battery after 5 years
of moderate use or 2 years of heavy use.
Moderate use is defined as recharged twice a
week. Heavy use is defined as discharged to
cutoff and recharged daily.
Batteries contain hazardous chemicals that can
cause burns or explode. If exposure to
chemicals occurs, clean with water and get
medical aid.
Do not short the battery terminals together.
Do not disassemble or crush battery cells and
battery packs.
Do not put battery cells and battery packs near
heat or fire. Do not put in sunlight.
True-rms Thermal Multimeter
Maintenance
XW
Warning
33

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents