Checking the hour meter

1. Disconnect the hour meter coupler from
the wiring harness.
2. Connect the positive battery lead to the
yellow (Y) terminal a, also connect the
negative battery lead to the black (B) ter-
minal b, and then check that the hour
meter displayed the all segments which
has been illuminated for 2 seconds.
Replace the hour meter if there is no illu-
minated.