Erase-Programming Additional Flash Elements; Reading Additional Flash Elements; Flash Elements Accesable Through Iap-Lite - Philips P89LPC902 User Manual

8-bit microcontrollers with accelerated two-clock 80c51 core 1kb 3v low-power byte-eraseable flash with 128 byte ram
Table of Contents

Advertisement

Philips Semiconductors
FLASH PROGRAM MEMORY
Table 14-1: Flash elements accesable through IAP-Lite
Element
Address Description
UCFG1
00h
User Configuration byte 1.
Boot Vector
02h
Boot vector
Status Bit
03h
Status bit byte
Security
08h
Security byte, sector 0
byte 0
Security
09h
Security byte, sector 1
byte 1
Security
0Ah
Security byte, sector 2
byte 2
Security
0Bh
Security byte, sector 3
byte3
Mfgr Id
10h
Signature byte, manufacturer id
Id_1
11h
Signature byte,id 1
Id_2
12h
Signature byte,id 2

Erase-programming additional flash elements

The erase-program cycle takes 4ms to complete and is accomplished using the following steps:
• Write the address of the flash element to FMADRL.
• Write the CONF command (6CH) to FMCON.
• Write the data to be programmed to FMDATA.
• Read FMCON to check status. If aborted, repeat this sequence.
Writing the data to be programmed to FMDATA will start the erase-program process and place the CPU in a program-idle state.
The CPU will remain in this idle state until the erase-program cycle is either completed or terminated by an interrupt. When the
program-idle state is exited, FMCON will contain status information for the cycle.
If an interrupt occurs during an erase/programming cycle, the erase/programming cycle will be aborted and the OI flag (Opera-
tion Interrupted) in FMCON will be set. If the application permits interrupts during erasing-programming the user code should
check the OI flag (FMCON.0) after each erase-programming operation to see if the operation was aborted. If the operation was
aborted, the user's code will need to repeat the process.

Reading additional flash elements

The read cycle is accomplished using the following steps:
• Write the address of the flash element to FMADRL.
• Write the CONF command (6CH) to FMCON.
• Read the data from FMDATA
The read cycle completes in a single machine cycle and thus will not enter an idle state. It can be interrupted. However, there is
no need to check status.
An assembly language routine to perform an erase/program operation of a flash element is shown in Figure 14-4. A similar C-
language routine is shown in Figure 14-5. A C-language routine to read a flash element is shown in Figure 14-6.
2003 Dec 8
97
User's Manual - Preliminary -
P89LPC901/902/903