Siemens SIRIUS 3RW44 User Manual page 243

Soft starter
Hide thumbs Also See for SIRIUS 3RW44:
Table of Contents

Advertisement

Soft
Line contactor up to
starters
400 V
Nominal
(option)
ToC
2
current
Q11
Q21
Type
A
Type
3)
Utilization class 2
: I
= 65 kA
q
3RW44 22
29
3RT10 34
3RW44 23
36
3RT10 35
3RW44 24
47
3RT10 36
3RW44 25
57
3RT10 44
3RW44 26
77
3RT10 45
3RW44 27
93
3RT10 46
3RW44 34
113
3RT10 54
3RW44 35
134
3RT10 55
3RW44 36
162
3RT10 56
3RW44 43
203
3RT10 64
3RW44 44
250
3RT10 65
3RW44 45
313
3RT10 75
3RW44 46
356
3RT10 75
3RW44 47
432
3RT10 76
3RW44 53
551
3TF68
44-0CM7
3RW44 54
615
3TF68
44-0CM7
3RW44 55
693
3TF69
44-0CM7
3RW44 56
780
3TF69
44-0CM7
3RW44 57
880
—2 x 3TF69 44-0CM7
3RW44 58
970
3RW44 65
1076
3RW44 66
1214
1) If the "Combined braking" stopping function is selected, no braking contactor is required.
If the "DC braking" function is selected, a braking contactor must be additionally used (for type, see table).
The "DC braking" function is recommended for applications with larger centrifugal masses (J
2) Additional K4 auxiliary relay:
LZX:RT4A4T30 (3RW44 soft starter with 230 V AC rated control supply voltage),
LZX:RT4A4S15 (3RW44 soft starter with 115 V AC rated control supply voltage).
3) "Utilization class 2" refers to the soft starter in combination with the protective device listed (circuit breaker/fuse), not to
other components in the branch. For utilization class, see page 10-20.
SIRIUS 3RW44 manual
GWA 4NEB 535 2195-02 DS 06
1)2)
Braking contactor
(Circuit suggestions from page 9-2)
Q91
Q92
Type
Type
3RT15 26
3RT15 26
3RT15 35
3RT15 35
3RT10 24
3RT10 35
3RT10 25
3RT10 36
3RT10 34
3RT10 44
3RT10 36
3RT10 45
3RT10 44
3RT10 45
3RT10 44
3RT10 54
3RT10 44
3RT10 55
3RT10 54
3RT10 56
3RT10 54
3RT10 56
3RT10 55
3RT10 64
3RT10 64
3RT10 66
3RT10 64
3RT10 75
3RT10 65
3RT10 75
3RT10 65
3RT10 75
3RT10 75
3RT10 76
3RT10 75
3RT10 76
3RT10 75
3TF68
3RT10 76
3TF68
Circuit breaker
440 V +10 %
Rated current
Q1
Type
A
3RV10 41-4HA10
50
3RV10 41-4JA10
63
3RV10 41-4KA10
75
3RV10 41-4LA10
90
3RV10 41-4MA10
100
3RV10 41-4MA10
100
3VL17
16-1DD36
160
3VL17
16-1DD36
160
3VL37
25-1DC36
250
3VL47
31-1DC36
315
3VL47
31-1DC36
315
3VL47
40-1DC36
400
3VL47
40-1DC36
400
3VL57
50-1DC36
500
3VL67
80-1AB36
800
3VL67
80-1AB36
800
3VL67
80-1AB36
800
3VL77
10-1AB36
1000
3VL77
10-1AB36
1000
3VL77
12-1AB36
1250
3VL77
12-1AB36
1250
3VL77
12-1AB36
1250
> J
).
load
motor
General Technical Data
Line fuse, maximum
690 V +5 %
Rated current
E1
Type
A
3NA3 820-6
50
3NA3 822-6
63
3NA3 824-6
80
3NA3 830-6
100
3NA3 132-6
125
3NA3 136-6
160
3NA3 244-6
250
3NA3 244-6
250
3NA3 365-6
500
2 x 3NA3 354-6
2 x 355
2 x 3NA3 354-6
2 x 355
2 x 3NA3 365-6
2 x 500
2 x 3NA3 365-6
2 x 500
2 x 3NA3 365-6
2 x 500
2 x 3NA3 365-6
2 x 500
2 x 3NA3 365-6
2 x 500
2 x 3NA3 365-6
2 x 500
2 x 3NA3 365-6
2 x 500
2 x 3NA3 365-6
2 x 500
3 x 3NA3 365-6
3 x 500
3 x 3NA3 365-6
3 x 500
3 x 3NA3 365-6
3 x 500
Size
00
00
00
00
1
1
2
2
3
3
3
3
3
3
3
3
3
3
3
3
3
3
10-25

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents