Free User-Interface - HP A7500 Series Command Reference Manual

Fundamentals
Hide thumbs Also See for A7500 Series:
Table of Contents

Advertisement

A flow control mode takes effect on both inbound and outbound directions. In inbound flow control, the
local device listens to the remote device for flow control information while in the outbound flow control,
the local device sends flow control information to the remote device.
Two ends must be configured with the same flow control mode.
NOTE:
The command is only applicable to the asynchronous serial port (console port).
The switch supports the none flow control mode only.
Examples
# Configure no flow control in the inbound and outbound directions for AUX 0.
<Sysname> system-view
[Sysname] user-interface aux 0
[Sysname-ui-aux0] flow-control none

free user-interface

Syntax
free user-interface { num1 | { aux | vty } num2 }
View
User view
Default level
3: Manage level
Parameters
num1: Absolute number of a user interface. The value range varies with devices, and typically starts from
0.
aux: Specifies the AUX user interface.
vty: Specifies the VTY user interface.
num2: Relative number of a user interface. The value range varies with devices for an AUX user interface
and the value is in the range of 0 to 15 for a VTY user interface.
Description
Use the free user-interface command to release the connection(s) established on the specified user
interface.
This command cannot release the connection that you are using.
Examples
# Release the connection established on user interface VTY 1.
Display the users that are operating the device.
<Sysname> display users
The user application information of the user interface(s):
Idx UI
+ 18
VTY 0
19
VTY 1
Following are more details.
Delay
Type Userlevel
00:00:00 TEL
3
00:09:51 TEL
3
26