display transceiver alarm

Syntax
display transceiver alarm interface [ interface-type interface-number ] [ | { begin | exclude | include }
regular-expression ]
View
Any view
Default level
2: System level
Parameters
interface [ interface-type interface-number ]: Displays alarms that are present on the specified or all
transceiver modules. The interface-type interface-number arguments specify an interface by its type and
number. If no interface is specified, the command displays present alarm information for all transceiver
modules.
|: Filters command output by specifying a regular expression. For more information about regular
expressions, see Fundamentals Configuration Guide.
begin: Displays the first line that matches the specified regular expression and all lines that follow.
exclude: Displays all lines that do not match the specified regular expression.
include: Displays all lines that match the specified regular expression.
regular-expression: Specifies a regular expression, a case-sensitive string of 1 to 256 characters.
Description
Use the display transceiver alarm command to display alarms present on transceiver modules.
If no error has occurred, None is displayed.
occur. Support for the transceiver modules depends on the device model.
Table 29 Common transceiver module alarms
Field
SFP/SFP+
RX loss of signal
RX power high
RX power low
TX fault
TX bias high
TX bias low
TX power high
TX power low
Temp high
Temp low
Voltage high
Table 29
describes the transceiver module
Remarks
Incoming (RX) signal is lost.
Incoming (RX) power level is high.
Incoming (RX) power level is low.
Transmit (TX) fault
TX bias current is high.
TX bias current is low.
TX power is high.
TX power is low.
Temperature is high.
Temperature is low.
Voltage is high.
180