6. DISASSEMBLY AND REASSEMBLY: MODULE QW-5311

6-1. REMOVING THE CROWN

1) Check that the crown is in the baseline position.
2) While pressing the setting lever with a thin stick through the removal opening, disengage and
remove the setting stem.
* The setting stem cannot be removed while the crown is pulled out.
Crown
baseline position
Note: After replacing the setting stem or the Center ASS'Y, apply silicon oil to the crown pipe.
Refer to P.1�

6-2. REMOVING THE MODULE

When removing the back cover, do not misplace the spring/coils. Please insert a precision screw driv-
er into the gap pointed an arrow between the module and the case.
SPRING/COIL 5311-1
Location of the setting lever
1�
"PUSH" is engraved here.
SPRING/COIL 5311-1
– 9 –
QW-5311
Setting stem