Philips MX400 Instructions For Use Manual Page 90

Intellivue series patient monitors.
Hide thumbs
   
1
2
Table of Contents
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534

Advertisement

4 Patient Alarms and INOPs
INOP Message, Indication
Tven INOPs
Tvesic INOPs
SpO2 INOPs
INOP Message, Indication
<SpO₂ Label> Chk Sensor The condition of the signal at the SpO
<SpO₂ Label> Deactivated
INOP tone
<SpO₂ Label> Equip Malf
Numeric is replaced by -?-
INOP tone
<SpO₂ Label> Erratic
Numeric is replaced by -?-
INOP tone
<SpO₂ Label>
Extd.Update
Numeric is replaced by -?-
(questionable numeric)
<SpO₂ Label>Interference
Numeric is replaced by -?-
INOP tone
<SpO₂ Label> Low Perf
Numeric is replaced by -?-
(questionable numeric)
<SpO₂ Label> No Pulse
Numeric is replaced by -?-
INOP tone
<SpO₂ Label> No Sensor
Numeric is replaced by -?-
INOP tone
<SpO₂ Label> NoisySignal
Numeric is replaced by -?-
INOP tone
<SpO₂ Label> Poor Signal
Numeric is replaced by -?-
(questionable numeric)
<SpO₂ Label> Pulse?
Numeric is replaced by -?-
INOP tone
<SpO₂ Label> Searching
Numeric unavailable
<SpO₂ Label> Sensor Malf
Numeric is replaced by -?-
INOP tone
90
What to do
See <Temp Label> INOPs
See <Temp Label> INOPs
What to do
Check proper application of the sensor in accordance with the Instructions for Use. If the INOP
persists, consider exchanging the sensor.
The SpO
measurement label in the measurement device has been deactivated by deactivating the label
2
in the Measurement Selection window. The measurement automatically disappears from the
display. To switch the measurement on again, reactivate the measurement label in the Measurement
Selection window.
The MMS or module is faulty. Unplug and replug the MMS or module. If the INOP persists, contact
your service personnel.
Check the sensor placement. Try another adapter cable and sensor. If the INOP persists, contact your
service personnel.
The update period of displayed values is extended due to an NBP measurement on the same limb or
an excessively noisy signal.
There is too much interference, caused by a high level of ambient light and/or electrical interference.
Cover the sensor to minimize ambient light. If the INOP persists, make sure that the sensor cable is
not damaged or positioned too close to power cables.
Accuracy may be compromised due to very low perfusion. Stimulate circulation at sensor site. If INOP
persists, change the measurement site.
Check the perfusion at measurement site. If necessary, stimulate circulation or change measurement
site. If the INOP is due to NBP measurement on the same limb, wait until the NBP measurement is
finished.
Make sure the SpO
sensor is connected. If the INOP persists, try another adapter cable and sensor. If
2
you silence this INOP, the measurement will be switched off.
Excessive patient movement or electrical interference is causing irregular pulse patterns. Try to reduce
patient movement or to relieve the cable strain on the sensor.
The signal condition of the SpO
compromised. If the INOP persists, consider changing the application site or using another sensor.
The detectable pulsations of the SpO
SpO
is analyzing the patient signal to derive Pulse, SpO
2
analysis is complete.
The SpO
sensor or adapter cable is faulty. Try another adapter cable and sensor. If the INOP persists,
2
contact your service personnel.
sensor is not as expected. Accuracy may be compromised.
2
measurement is poor and measurement accuracy may be
2
signal are outside the specified pulse rate range.
2
and Perf values. Please wait until the search
2

Advertisement

Table of Contents

This manual is also suitable for:

Mx700Mx800Mx450Mx500Mx550Mx600

Comments to this Manuals

Symbols: 0
Latest comments: