Download  Print this page

Philips MX400 Instructions For Use Manual Page 83

Intellivue series patient monitors.
Hide thumbs
   
1
2
Table of Contents
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534

Advertisement

INOP Message, Indication
No Central Monit.
INOP tone
No ECG at Central
OtherMon INOP
!! OtherMon INOP
!!! OtherMon INOP
Rem.AlarmDev.Malf.
INOP tone
Settings Malfunct
INOP tone
Speaker Malfunct
INOP tone
SRR Incompatible
INOP tone
SRR Interference
INOP tone
SRR Invalid Chan
INOP tone
SRR Malfunction
INOP tone
TAAP Disabled
INOP tone
Tele Config Unsupp
INOP tone
Tele ECG Malfunct.
Numeric is displayed with a -?-
INOP tone
Tele Equip Malf
INOP tone
Tele Incompatible
Tele INOP
!! Tele INOP
!!! Tele INOP
Tele Unsupported
INOP tone
TimeExpired:<Timer
Label>
INOP tone
T-Mon INOP
!! T-Mon INOP
!!! T-Mon INOP
INOP tone
TransportEquipment
What to do
There is a problem with the communication to the network. Central monitoring is currently not
possible (no patient alarms or information). Check the connection. In case the connection is via a
telemetry device, the current telemetry use model does not support central monitoring. Contact your
service personnel.
The ECG measured with the monitor ECG is not being sent to the Information Center via the
telemetry device.
Another monitor assigned to the patient (e.g. a transport monitor) is in an INOP condition. Check the
detailed INOP information at the Information Center and resolve the INOP condition(s) at the other
monitor.
There is a problem with the connection to the remote alert device. Contact your service personnel to
check the remote alert device and its connections.
The monitor cannot use the predefined settings for monitoring. Contact your service personnel.
Contact your service personnel to check the speaker and the connection to the speaker.
The short range radio component has compatibility problems. Contact your service personnel.
The short range radio connection has interference from another device. Try using another channel.
The channel configuration of the Short Range Radio is invalid. Check channel and channel mask
configuration.
Malfunction in the short range radio device. If the INOP persists contact your service personnel.
The currently selected telemetry configuration on the monitor does not allow connection of telemetry
devices to the monitor.
Telemetry Workflow configuration not supported. Check revision and configuration of monitor and
central.
Contact your service personnel.
The ECG in the Telemetry device is faulty.
The telemetry device has a malfunction. Disconnect and reconnect the telemetry device. If the INOP
reappears, replace the telemetry device.
SRR-enabled telemetry device is not supported by this central software revision. Please check
configuration.
A telemetry device assigned to the patient is in an INOP condition. Check the detailed INOP
information at the Information Center and resolve the INOP condition(s) at the telemetry device.
This telemetry device is not supported for direct connection to the monitor.
The time has expired for the timer indicated in the INOP text. Clearing the timer clears the INOP.
A transport monitor assigned to the patient is in an INOP condition. Check the detailed INOP
information at the Information Center and resolve the INOP condition(s) at the transport monitor.
The equipment is ready for transport. See the Equipment window for details.
4 Patient Alarms and INOPs
83

Advertisement

Table of Contents

This manual is also suitable for:

Mx700Mx800Mx450Mx500Mx550Mx600

Comments to this Manuals

Symbols: 0
Latest comments: