Download  Print this page

Philips MX400 Instructions For Use Manual Page 124

Intellivue series patient monitors.
Hide thumbs
   
1
2
Table of Contents
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534

Advertisement

5 Managing Patients and Equipment
source is a patient monitor connected to the Information Center via IntelliVue Instrument Telemetry
(IIT), only the adjust HR alarms setting is available.
Viewing and Silencing Other Device Alarms at the Bedside
When other devices are assigned to the patient, alarms from those devices will also be indicated on the
monitor, in addition to the main indication at the Information Center.
If configured, a generic alarm message will appear in the alarm status area with standard alarm tones.
The alarm message will have the color and * or ! coding corresponding to the severity of the alarm.
The specific alarm message (for example
If configured, alarms generated from another device can be silenced at the bedside. Either the monitor
Silence
key is configured to silence both monitor and other device alarms (must be configured at the
Information Center) or the
Select the own patient overview window.
1
Select the
2
Depending on your Information Center configuration, the
device alarms and bedside alarms.
WARNING
Even when the other device data is not visible on the screen, you may be silencing monitor alarms and
other device alarms, if the Information Center and monitor are so configured.
Switching Off or Pausing Alarms From Other Devices
When you select
bedside measurements. When you switch alarms off or pause alarms at the Information Center, both
monitor alarms and alarms from other assigned devices are affected.
Refer to the Information Center Instructions for Use for more details on the Suspend/Pause alarms
behavior of the Information Center.
Using Standby
When you select Standby mode at the monitor, the bedside goes into Standby mode but other assigned
devices may continue monitoring.
Refer to the Information Center Instructions for Use for details on how selecting Standby at the
Information Center affects the monitor and other devices.
ECG Source Tracking at the Information Center
The Information Center continuously checks whether a valid ECG signal is coming from the monitor
or from another assigned device. If you unplug the ECG patient cable from the monitor and plug it
into another device, the Information Center will automatically switch to monitoring the ECG from the
other device. At the monitor, its own ECG measurement will be deactivated and the
will no longer be accessible.
When you unplug the patient cable from the other device and plug it back into the monitor again, the
Information Center will switch back to monitoring the ECG from the monitor.
124
Silence Bed
Silence Bed
pop-up key.
Pause Alarms
Alarms Off
or
** HR Low
) will appear in the own patient overview window.
pop-up key will be available:
Silence Bed
at the monitor, the alarms are off or paused for the
key may silence both other
Setup ECG
menu

Advertisement

Table of Contents

This manual is also suitable for:

Mx700Mx800Mx450Mx500Mx550Mx600

Comments to this Manuals

Symbols: 0
Latest comments: