Parameter Attributes - Siemens SINAMICS G120 Operating Instructions Manual

Hide thumbs Also See for SINAMICS G120:
Table of Contents

Advertisement

Commissioning (software)
5.2 Parameters
5.2.3

Parameter Attributes

Overview
In the Parameter List, the header line of each parameter shows all the attributes and groups
for that specific parameter. The figure below shows the details for parameter P0700 and
r1515.
Figure 5-2
Figure 5-3
Index
Using the index, a parameter (e.g. p0013[20]) is defined with several consecutive elements
(in this case, 20). Each individual index is defined using a numerical value.
When transferred to a parameter this means that an indexed parameter can have several
values. The values are addressed using the parameter number including the index value
(e.g. p0013[0], p0013[1], p0013[2], p0013[3], p0013[4], ...).
Indexed parameters are used, for example:
● Drive Data Sets (DDS)
● Command Data Sets (CDS)
● Sub functions.
5-4
Description of attributes for parameter P0700
Description of attributes for parameter r1515
Operating Instructions, 11/2006, A5E00766042B AA