HP Synergy 480 Gen9 Maintenance And Service Manual Page 44

Compute module.
Hide thumbs

Advertisement

CAUTION:
THE PINS ON THE SYSTEM BOARD ARE VERY FRAGILE AND EASILY DAMAGED. To avoid
damage to the system board, do not touch the processor or the processor socket contacts.
2. Close the processor retaining bracket. When the processor is installed properly inside the processor
retaining bracket, the processor retaining bracket clears the flange on the front of the socket.
CAUTION:
Do not press down on the processor. Pressing down on the processor might damage the processor
socket and the system board. Press only in the area indicated on the processor retaining bracket.
3. Press and hold the processor retaining bracket in place, and then close each processor locking lever.
Press only in the area indicated on the processor retaining bracket.
4. Align and install the heatsink. Alternate tightening the screws until the heatsink is seated properly.
5. Install all DIMM baffles.
6. Install the access panel.
7. Install the compute module.
44
Removal and replacement procedures
2
2
1
2
2