Connecting the MiniScan
To connect the MiniScan to the host, connect the imager cables in the order shown in
Typical Connection Diagram
Figure 2-4
Male jack shown for reference
1
2
3
Note: Due to many variations of
jack and socket styles, identify
terminals as shown before
soldering leads.
Trigger Jack Connector Pins
Figure 2-5
To Host
3
5
Trigger or Photo
Sensor (Optional)
Insertion
Direction
1 - Ground (Sleeve)
1 - Ground (Sleeve)
2 - Vcc (Middle Contact)
2 - Battery (Middle Contact)
3 - Trigger (Tip)
3 - Trigger (Tip)
4
1
Trigger Jack (Optional)
See
Figure 2-5
2
1
2
3
Getting Started
2 - 5
Figure
2-4.