11 - 34 Symbol MS4404/MS4407 Integration Guide
Clear Transmission Buffer
To clear the transmission buffer, capture the Clear Buffer bar code below, which contains only a start character, a
dash (minus), and a stop character.
The imager issues a short high/low/high beep.
The imager erases the transmission buffer.
No transmission occurs.
Clear Buffer
NOTE The Clear Buffer contains only the dash (minus) character. To decode this command, set the Code 39
length to include length 1.
Transmit Buffer
There are two methods to transmit the Code 39 buffer.
Capture the Transmit Buffer bar code below, which contains only a start character, a plus (+), and a stop
1.
character.
The imager transmits and clears the buffer.
The imager issues a Low/High beep.
Capture a Code 39 bar code with a leading character other than a space.
2.
The imager appends new decode data to buffered data.
The imager transmits and clears the buffer.
The imager signals that the buffer was transmitted with a low/high beep.
The imager transmits and clears the buffer.
NOTE The Transmit Buffer contains only a plus (+) character. To decode this command, set the Code 39 length to
include length 1.
Transmit Buffer