KRONOS system version ... update
complete. Please restart the system.
Meaning: This message will appear when you've used the
Global P0 page menu command Update System Software,
after the update is complete. Restart the system to use the
updated software.
• Turn the power switch off, and then on again.
M (Master–Multisample)
Master Track can't be recorded alone
Meaning: When real-time-recording a single track, you
attempted to begin recording with the master track as the
current track.
• Select a MIDI or Audio Track for recording, instead of
the Master Track.
Master Track is empty
Meaning: You cannot open Audio Event Edit because the
Master Track is empty. To solve this problem:
• Execute the Sequencer P4– Track Edit page menu
command Set Song Length etc. with an appropriate
length to create a master track, and then open Audio
Event Edit.
Measure number over limit
Meaning: The attempted edit operation would cause the
track length to exceed 999 measures.
• Delete unnecessary measures.
Measure size over limit
Meaning: When loading a Standard MIDI File, the number
of events in a measure exceeded the maximum
(approximately 65,535 events).
Meaning: The attempted edit operation would cause the
maximum number of events in a measure (approximately
65,535) to be exceeded.
To solve either of these problems:
• Use event editing etc. to delete unwanted data.
Medium changed
Meaning: When executing the Copy command in the Disk
mode Utility page, the media was exchanged or ejected, and
it was not possible to copy between separate media on the
same drive.
Medium unavailable
Meaning: You selected a medium that does not allow
writing.
Error and confirmation messages K
Medium write protected
Meaning: The other writing-destination media is write-
protected.
• Turn off write protect on the other media, and execute
the command once again.
Memory full
Meaning: In Sequencer mode when editing a song, track or
pattern, the total data of all songs has used up all of the
sequence data memory, and further editing is not possible.
To solve this problem:
• Delete other song data etc. to increase the amount of free
memory.
Meaning: While real-time recording in Sequencer mode,
there is no more free memory to accommodate the recorded
data, so recording has been forcibly halted. To solve this
problem:
• Delete other song data etc. to increase the amount of free
memory.
Memory overflow
Meaning: While receiving exclusive data in Disk mode
Save Exclusive, all remaining internal memory was used up.
To solve this problem:
• If you are receiving two or more sets of exclusive data,
transmit them separately to the KRONOS.
Meaning: In Disk mode, you attempted to load more sample
waveform data than there was free memory capacity. To
solve this problem:
• In Sampling mode, execute Delete sample to create free
space in the sample waveform data area, and re-load the
data.
Memory Protected
Meaning: The internal program, combination, song, drum
kit, wave sequence, KARMA GE, or Internal HDD Save is
protected.
Meaning: The song was protected when you executed.
• In Global mode, turn off write-protect, and execute the
write or load operation once again.