Venting Information - Maytag *TC Installation Instructions Manual

Two-stage condensing gas furnaces with fixed & variable speed blowers - 95.1 % afue
Table of Contents

Advertisement

VENT TERMINAL
Clearance Location
Clearance above grade, veranda, porch, deck,
A
balcony, or maximum expected snow level.
B
Clearance to window or door that may be opened.
C
Clearance to permanently closed window
Vertical clearance to ventilated soffi t located above the
D
terminal within a horizontal distance of 2 feet (61cm)
from the center line of the terminal.
E
Clearance to unventilated soffi t.
F
Clearance to outside corner.
G
Clearance to inside corner.
Clearance to each side of center line extended above
H
meter/regulator assembly.
I
Clearance to service regulator vent outlet.
Clearance to non-mechanical air supply inlet to
J
building or the combustion air inlet to any other
appliance.
K
Clearance to mechanical air supply inlet.
Clearance above paved sidewalk or driveway located
L
on public property.
M
Clearance under veranda, porch, deck, or balcony.
a
In accordance with the current CSA B149.1 Natural Gas and Propane Installation Guide Code
b
In accordance with the current ANSI Z223.1 / NFPA 54 Natural Fuel Gas Code
c
A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings and serves both dwellings.
d
Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the fl oor.
For clearances not specifi ed in ANSI Z223.1 / NFPA 54 or CSA B149.1, the following statement shall be included: "Clearance in accordance with local installation codes, and the requirements of the
*
gas supplier and the manufacturers installation instructions." / "Dégagement conforme aux codes d'installation locaux, aux exigences du fournisseur de gaz et aux
instructions d'installation du fabricant".

VENTING INFORMATION

AIR SUPPLY INLET
CANADIAN INSTALLATIONS
Direct Vent (2-pipe) &
Conventional Vent (1-pipe)
Furnaces
12 inches (30cm)
6 inches (15cm) for appliances
< 10,000 Btuh (3kW)
12 inches (30cm) for appliances
10,000 Btuh - 100,000 Btuh (30kW)
36 inches (91cm) for appliances
> 100,000 Btuh (30Kw)
*
*
*
*
*
3 feet (91cm) within a height 15 feet
above the meter/regulator assembly
3 feet (1.83m)
6 inches (15cm) for appliances
< 10,000 Btuh (3kW)
12 inches (30cm) for appliances
10,000 Btuh - 100,000 Btuh (30kW)
36 inches (91cm) for appliances
> 100,000 Btuh (30Kw)
6 feet (1.83m)
c
7 feet (2.13m)
d
12 inches (30cm)
NOTES:
Table 17. Vent Termination Clearances
AREA WHERE TERMINAL IS NOT PERMITTED
a
US INSTALLATIONS
Direct Vent
(2-pipe) Furnaces
12 inches (30cm)
6 inches (15cm) for appliances
< 10,000 Btuh (3kW)
9 inches (23cm) for appliances
10,000 Btuh - 50,000 Btuh (30kW)
12 inches (30cm) for appliances
> 50,000 Btuh (30Kw)
*
*
*
*
*
*
*
6 inches (15cm) for appliances
< 10,000 Btuh (3kW)
9 inches (23cm) for appliances
10,000 Btuh - 50,000 Btuh (30kW)
12 inches (30cm) for appliances
> 50,000 Btuh (30Kw)
3 feet (91cm) above if within
10 feet (3m) horizontally
*
*
b
Conventional Vent
(1-pipe) Furnaces
12 inches (30cm)
4 ft. (1.2m) below or to side of opening;
1 ft. (300mm) above opening
*
*
*
*
*
*
*
4 ft. (1.2m) below or to side of opening;
1 ft. (300mm) above opening
3 ft. (91cm) above if within
10 feet (3m) horizontally
7 ft. (2.13m)
*
45