Menus and dialog boxes for SIMATIC PDM in the SIMATIC Manager
9.1 "Edit" menu
Field
Short address*
(default value: 1)
* Entry can be changed.
Table 9-1
Field
Master type
(default value:
Secondary master)
"Ignore secondary
master" check box
"Prefer 'Long address'"
check box
MODBUS
communication
(default value: Serial)
Response time*
(default value: 1000 ms)
Subnet ID*
(default value:
0x00000000)
PROFIBUS CP slot*
(default value: 2)
DP master address*
(default value: 1)
Long address*
(default value:
0x0000000000)
* Entry can be changed.
NOTICE
HART device replacement
For a device replacement, this long address must be set to 0 so that a replacement device
can be newly identified.
The replacement device must be the only device on the HART modem.
198
Explanations/operating instructions
The short address is displayed here for HART devices.
"Properties" area
Explanations/operating instructions
The HART modem uses the serial port of a PC and a HART modem or HART
interface connected to it to communicate with the connected HART devices.
It can be both primary and secondary master.
If there is no secondary master, the time behavior can be optimized and
devices can be addressed faster by enabling this option.
Once a device is known, communication with it is performed only via the long
address. In this case, multiple devices on the same HART modem can have
the short address 0. To make a device known with short address, no other
devices can be connected to the HART modem.
Serial: COM interface must be suitably set for the device. (interface, baud
rate, etc)
IrDA: USB infrared adapter required. The device (1 at a time) then
communicates via this adapter. (multiple USB IR adapters are not
supported.)
This is the time waited to obtain a response from a MODBUS device. If this
value is too low, it is possible that no connection to the device will be made.
If it is too high, the communication can be extremely slow.
The S7 subnet ID of the network. This parameter is optional - this value is
ignored when configuring via HW Config.
The slot address of the PROFIBUS network. This parameter is optional - this
value is ignored when configuring via HW Config.
The address of the hierarchical master on the bus. This parameter is optional
- this value is ignored when configuring via HW Config.
For HART devices, the long address is displayed here.
As soon as the device is known, the long address is stored.
Help for SIMATIC PDM (V8.2)
Operating Manual, 02/2014, A5E33203676-AA