Power Specifications
Table B-1
Power Specifications for the Cisco Nexus Fabric Extender (continued)
Power Supply
Cisco Nexus
N2K-PAC-200W
Fabric
Extender
Heat
560/680 BTU/hr
Dissipation
(typical/maximum)
Power Cord
3 A@100 Vin,
Rating
1.5 A@240 Vin
Cubic Inches
51 in^3
Power Density
3.9 W/in^3
Operating
50°C
Temperature
Cooling
Internal fans to cool
the supply
Input connector AC connector in the
power supply face
Output
DC output
connector
connector in the
back
Supply
Supply Health:
Indicators
Green indicates the
power supply is
operational and red
indicates a fault.
AC good indicator:
Solid green
indicates that AC is
present and is
within the supply
specifications.
Cisco Nexus 2000 Series Hardware Installation Guide
B-4
N2200-PAC-400W (Blue)
N2200-PAC-400W-B (Red)
Cisco Nexus 2332TQ:
510/850 BTU/hour (typical/maximum)
Cisco Nexus 2348TQ and 2348TQ-E:
952/1190 BTU/hour (typical/maximum)
Cisco Nexus 2348UPQ:
425/680 BTU/hour (typical/maximum)
Cisco Nexus 2248TP-E and 2248TP:
374/442 BTU/hour (typical/maximum)
Cisco Nexus 2232PP:
918BTU/hour (typical)
Cisco Nexus 2224TP:
289/340 BTU/hour (typical/maximum)
Cisco Nexus 2232TM:
1190/1312 BTU/hour (typical/maximum)
6 A@100 Vin,
3 A@240 Vin
39 in^3
10.2 W/in^3
50°C
Internal fans to cool the
supply
AC connector in the power
supply face
DC output connector in the
back
Supply Health: Green
indicates the power supply
is operational and amber
indicates a fault.
AC good indicator: Solid
green indicates that AC is
present and is within the
supply specifications.
Appendix B
N2200-PDC-400W (Blue)
N2200-PDC-350W-B
15A@-48Vin,
8A@-60Vin
39 in^3
10.2 W/in^3
50°C
Internal fans to cool the
supply
DC connector in the power
supply face
DC output connector in the
back
Supply Health: Green
indicates the power supply
is operational and amber
indicates a fault.
Technical Specifications
NXA-PHV-500W (Blue)
NXA-PHV-500W-B (Red)
4A @ 240Vin and 277Vin,
3A@ 380 Vin
39 in^3
10.2 W/in^3
50°C
Internal fans to cool the
supply
HVAC + HVDC connector
in the power supply face
DC output connector in the
back
Supply Health: Green
indicates the power supply
is operational and amber
indicates a fault.

Advertisement