Adjusting a Play in the Moving Head
Needle drop adjusting rail
Adjusting roller
1. Remove the static head cover (right).
2. Check the play in the direction of the arrows.
If there is a detectable play, loosen the
setscrew and tighten it while pressing the
adjusting roller against the needle drop adjust-
ing rail.
Setscrew
3. Adjust the needle drop position (see page 24).
4. Attach the static head cover (right).