Archgard EURO-25 Installation And Operation Instructions Manual

Vented gas fireplace insert heating appliance

Advertisement

INSTALLATION AND OPERATION INSTRUCTIONS
f i r e - p a r t s . c o m
DO NOT store or use gasoline or any other flammable vapors or liquids in the vicinity
of this or any other appliance
IF YOU SMELL GAS:
- Do not try to light any appliance.
- Open windows.
- Do not touch electrical switches.
- Extinguish any open flame.
- Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's
instructions.
- If you cannot reach the gas supplier, call the fire department.
- Do not use this appliance if any part has been under water. Immediately call a
qualified service technician to inspect the appliance and to replace any part of the
control system and any control which has been under water.
PLEASE READ INSTRUCTIONS CAREFULLY BEFORE INSTALLING AND
WARNING: Improper installation, adjustment, alteration, service or maintenance
Installation and service must be performed by a qualified installer, service agency or the
gas supplier.
Installer, please leave this manual with the appliance owner for future reference.
FOR USE WITH NATURAL GAS AND PROPANE
FOR YOUR SAFETY
OPERATING THE APPLIANCE
voids all the manufacturer's warranties and may cause property damage,
personal injury or loss of life.
NOT FOR USE WITH SOLID FUEL
200-0045
13NOV01

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EURO-25 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Archgard EURO-25

  • Page 1 FOR USE WITH NATURAL GAS AND PROPANE INSTALLATION AND OPERATION INSTRUCTIONS FOR YOUR SAFETY f i r e - p a r t s . c o m DO NOT store or use gasoline or any other flammable vapors or liquids in the vicinity of this or any other appliance IF YOU SMELL GAS: - Do not try to light any appliance.
  • Page 2: Table Of Contents

    APPENDIX A, Installation Into Vented Gas Fireplaces 21 - 24 Suitable Host Fireplaces and Specific Installation Instructions 25 - 29 Important Information Form Warranty Replacement Parts Manufactured by Archgard Industries Ltd., 7116 Beatty Drive, Mission, B.C., Canada. V2V 6B4 Patents Pending...
  • Page 3: Introduction

    INTRODUCTION Thank you for purchasing the Archgard Euro-25 Gas Fireplace Insert Heater. The Euro-25 is one of the most advanced gas heating appliance on the market. It is designed using the latest technology and manufactured to the highest quality. Some of the many features are: ∗...
  • Page 4: General Information

    - ANSI Z21.50-1996/CGA 2.22-M96, Vented Gas Fireplace, and - CAN/CGA-2.17-M91, Gas-Fired Appliances for Use at High Altitudes. This certification and installation manual also covers the Euro-25 insert. Please contact Archgard Industries Ltd., if you have any questions regarding the certification of these appliances.
  • Page 5: Appliance Description And Dimensions

    APPLIANCE DESCRIPTION & DIMENSIONS FRONT SURROUND TOP LOUVERS BAY GLASS DOOR CONVECTION FAN SPEED CONTROL GAS VALVE f i r e - p a r t s . c o m SPARKER REMOVABLE CONTROL COVER APPLIANCE DIMENSIONS 30 1/4” (768 mm) 19 1/4”...
  • Page 6: Installation Instructions

    CAUTION: This appliance is designed for use in any masonry, factory-built wood burning and specific zero-clearance vented gas fireplaces (Due to constant additions, contact Archgard Industries for an updated list of suitable gas fireplaces). This appliance cannot be enclosed with combustible material and...
  • Page 7 INSTALLATION INSTRUCTIONS Cont... MINIMUM MASONRY FIREPLACE DIMENSIONS SIDE TOP VIEW 12” (305 19 1/2” (495 mm) 17” (432 mm) 25” (635 mm) The standard flue adapter will fit if is less than 7”. It will also fit if is higher than 8” and is less than 7”.
  • Page 8 INSTALLATION INSTRUCTIONS Cont... MINIMUM ZERO-CLEARANCE WOOD BURNING FIREPLACE DIMENSIONS SIDE TOP VIEW 12” (305 15 1/4” (387 mm) 17” (432 mm) 25” (635 mm) f i r e - p a r t s . c o m The standard flue adapter will fit if X is less than 7”. It will also fit if Y is higher than 8” and Z is less than 7”. The extended flue adapter (Part # FAE25) will fit for X less than 10”, or Y is higher than 8”...
  • Page 9 INSTALLATION INSTRUCTIONS Cont... To install the Euro 25 into a vented gas fireplaces, see APPENDIX A for installation instructions. PRECAUTIONS • This appliance must be installed by a qualified gas installer and the installation conform to the installation codes. • This appliance needs fresh air for safe operation and must be installed so there are provisions for adequate combustion and ventilation air.
  • Page 10: Gas Connections

    INSTALLATION INSTRUCTIONS Cont... VENTING Cont... Caution: Make sure the flue adapter plate is not too far back. Otherwise the appliance will not vent properly. The arms on the adapter plate must not pass the rectangular hole on top of the appliance. NOTE: the arms on the adapter plate is not past the rectangular hole.
  • Page 11 INSTALLATION INSTRUCTIONS Cont... ATTACHMENT OF FIREPLACE SURROUND The surround has four hooks that clips onto the sides of the appliance. Make sure the surround sits evenly with the front of the fireplace. After the surround is properly installed, the bottom of the mid section of the surround is about 3/4” from the top of the f i r e - p a r t s .
  • Page 12 INSTALLATION INSTRUCTIONS Cont... GLASS DOOR WARNING: Glass door is fragile. Do not strike or abuse glass. Do not operate appliance with broken glass. Do not attempt to fix a broken glass door. It must be replaced with an identical one from the manufacturer. Do not attempt to remove the glass door when the appliance is hot. Removing the Glass Door Remove the louvers by lifting and unhooking it off the appliance.
  • Page 13 INSTALLATION INSTRUCTIONS Cont... PLACEMENT OF LOG SET, FIBER COALS & EMBER WOOL Place the back log at the back of the burner tray as shown, behind the two tabs on the burner • tray. A bag of fiber coals and a bag of ember wool are provided with the heater. •...
  • Page 14: Operation Instructions

    OPERATION INSTRUCTIONS FOR YOUR SAFETY, READ BEFORE LIGHTING INITIAL OPERATION Check that the appliance is properly vented and connected to the gas supply. • Check that the logs and branches are properly placed. • Check all external parts, such as grills, door and control cover are properly attached and •...
  • Page 15 OPERATION INSTRUCTIONS Cont.. START-UP PROCEDURE Set the thermostat, if present, to the lowest level. Set the flame adjustment knob to the HI position. Press slightly and turn the control knob clockwise to the OFF position and wait 5 minutes; thus allowing any gases to escape which may have accumulated in the combustion chamber.
  • Page 16: Maintenance

    MAINTENANCE CAUTION : Only conduct maintenance on a cold appliance. CLEANING THE APPLIANCE The exterior painted surfaces, glass and gold trims may be cleaned with a soft, non-abrasive cloth and water or a suitable, mild, non-abrasive cleaner. Regularly, Clean and remove any lint accumulations or debris from the grills and in any •...
  • Page 17: Trouble Shooting Instructions

    TROUBLE SHOOTING Please check to make sure the instructions are followed exactly before attempting trouble shooting of the appliance. WARNING: Trouble shooting and servicing of gas and electrical devices of the appliance should only be conducted by a qualified service technician. SYMPTOM ACTION Pilot will not light after pressing the...
  • Page 18 TROUBLE SHOOTING Cont... SYMPTOM ACTION The main burner does not turn on with 3. Check to make sure the thermostat is set high enough to turn on the appliance. the pilot lit. Cont... 4. Check that the remote switch or the thermostat is turned on. 5.
  • Page 19: Servicing

    SERVICING SERVICING UNDER WARRANTY Before servicing, read the terms and conditions of the Archgard warranty at the back of the manual. Contact the Archgard authorized dealer from which you have purchased the appliance and provide him with details of the problem and the installation information which the installer has filled out at the back of this manual.
  • Page 20 SERVICING Cont... REPLACEMENT OF FAN Disconnect the power to the appliance. • Remove the louvers, control cover and the door. • Remove the firebox back/baffle by removing the two screws holding the tabs of the baffle to the • side of the firebox. Remove the eight screws located at the back of the firebox. Take the firebox back/baffle out.
  • Page 21 SERVICING Cont... REPLACING MAJOR GAS COMPONENTS If any or the major gas components need to be replaced, such as the pilot or the gas valve, we recommend replacing the complete gas component assembly. The assembly is designed to be quickly and easily replaced with minimal inconvenience to the customer. Once replaced, the service technician can repair the defective assembly safely and comfortably in his shop and with the right tools and test equipment.
  • Page 22: Appendix A, Installation Into Vented Gas Fireplaces

    Archgard’s list of suitable gas fireplaces. Each of these fireplaces was tested and approved for use with the EURO 25. Please contact Archgard Industries for an updated list of gas fireplaces and any additional installation instructions. Due to constant additions, a list cannot be included in with this manual.
  • Page 23 • Remove the burner or sandpan, pilot, and all parts of the gas train assembly. • Attach the Archgard modification warning plate (see sample, page 24) to the • host fireplace label. Attach the warning label (see sample, page 24) provided with the EURO 25 •...
  • Page 24 EURO-25 INSTALLATION INSTRUCTIONS FOR INSTALLATION INTO VENTED GAS FIREPLACES Cont... VENTING OF THE EURO-25 INSIDE THE HOST GAS FIREPLACE A connector kit (BCV4-KIT or BCV5-KIT) is used to connect the EURO 25 insert to the host gas fireplace’s venting system. The connector slips into the host fireplace’s B-vent.
  • Page 25 : This fireplace has been modified for use with the Archgard EURO-25 gas insert. Usage f i r e - p a r t s . c o m without the EURO-25 gas insert may cause property damage, personal injury or loss of life.
  • Page 26 All installation requirement in the manual must also be carefully observed and followed. 7. Use Archgard BCV5 connector kit to connect the insert to the host’s B-vent or connect a 4” diameter flexible aluminum gas vent from the insert to the host’s vent cap.
  • Page 27 - p a r t s . c o m carefully observed and followed. 6. Use Archgard BCV5 connector kit to connect the insert to the host’s B-vent or connect a 4” diameter flexible aluminum gas vent from the insert to the host’s vent cap.
  • Page 28 All installation requirement in the manual must also be carefully observed and followed. 8. Use Archgard BCV5 connector kit to connect the insert to the host’s B-vent or connect a 4” diameter flexible aluminum gas vent from the insert to the host’s vent cap.
  • Page 29 All installation requirement in the manual must also be carefully observed and followed. 8. Use Archgard BCV5 connector kit to connect the insert to the host’s B-vent or connect a 4” diameter flexible aluminum gas vent from the insert to the host’s vent cap.
  • Page 30 - p a r t s . c o m carefully observed and followed. 8. Use Archgard BCV5 connector kit to connect the insert to the host’s B-vent or connect a 4” diameter flexible aluminum gas vent from the insert to the host’s vent cap.
  • Page 31: Important Information Form

    IMPORTANT INFORMATION * Please have the installer fill-out the installation information for warranty and future reference. APPLIANCE MODEL NUMBER EURO-25 SERIAL NUMBER GAS TYPE NATURAL GAS VALVE TYPE Robertshaw 7000MVRB DATE PURCHASED OWNER NAME ADDRESS CITY STATE/PROVINCE f i r e - p a r t s . c o m...
  • Page 32: Warranty

    Place of Purchase Date of Purchase Problem Description NOTE: Warranty may be void if work is carried out by unqualified personnel. Only original Archgard parts may be used. Please consult your Archgard representative if in doubt. OBTAINING WARRANTY SERVICE: To obtain warranty service, the consumer shall return the defective part to the original selling dealer transportation prepaid, along with the serial number of the appliance and proof of purchase.
  • Page 33: Replacement Parts

    Replacement Parts for EURO-25 Item # Item Description Qty Unit 200-0045 OWNER'S MANUAL, EURO 25 1 EA 301-0006 PANEL NUT FOR BULKHEAD ORIFICES 1 EA 301-0009 TUBING 3/8 DIA. ALUMINUM 4.75 IN 301-0010 SLEEVE 3/8 STD COMPRESSION 36/38 1 EA...
  • Page 34: 7116 Beatty Drive, Mission, B.c., Canada. V2V 6B4

    Postage WARRANTY REGISTRATION ARCHGARD INDUSTRIES LTD. 7116 BEATTY DRIVE MISSION, B.C. CANADA V2V 6B4 FOLD DOWN AT LINE f i r e - p a r t s . c o m FOLD DOWN AT LINE & TAPE CLOSED Model No:____________________________...