Power Supply Adjustments; Channel B-A Check; Adjustment And Calibration; Cover Removal - HP 3300A Technical Manual

Generator, signal sg-747/u
Table of Contents

Advertisement

Model 3300A
b.
Connect the instruments as shown in Figure
5-2.
Remove FREQ.
CONTROL shorting bar.
c.
Set 3300A controls as follows:
CHANNEL A function switch ......SINE
RANGE switch............................X10
CHANNEL A AMPLITUDE .........Max. CW
d.
Monitor frequency as power supply is varied
from 0 to -10 volts. Frequency should vary
over the decade, 10 to 100 cycles.
5-20.

CHANNEL B-A CHECK.

a.
Test equipment required: Oscilloscope (-hp-
Model 175A/1750B).
b.
Connect CHANNEL A OUTPUT to one
channel of the oscilloscope and CHANNEL
B OUTPUT to the other channel of the
oscilloscope.
c.
Set 3300A controls as follows:
CHANNEL A function switch ......SINE
CHANNEL B function switch ......-A
d.
The output of CHANNEL B should be a sine
wave, but 1800 out of phase with the output
of CHANNEL A.
5-21.

ADJUSTMENT AND CALIBRATION.

5-22.

COVER REMOVAL.

When it is necessary to repair or adjust the Model
3300A, one or more covers will have to be removed. To
remove either the top or bottom cover, remove the two
phillips screws and slide the cover to the rear.
Allow a 30-minute warm-up period
before making any adjustments.
5-23.

POWER SUPPLY ADJUSTMENTS.

5-24.
The adjustment and calibration procedures are
designed to adjust and calibrate the -hp- Model 3300A
and should be undertaken only if the performance
checks
indicate
the
specifications.
(See
identification and indication.)
5-25.
The measurement points, adjustments and
voltage limits are given in Table 5-2. Refer to Figure 5-4
for convenient top and bottom chassis location for
monitoring supply voltage. Supplies should be adjusted
in the following order: -26. 5V, +26.5 V, -20 V, +20 V.
The supplies should be rechecked and, if necessary,
readjusted in the same order.
5-26.

POWER SUPPLY RIPPLE CHECK.

POWER
SUPPLY
+40
ANY RED WIRE (except on S2)
-40
ANY VIOLET WIRE
-26.5
ANY WHITE/VIOLET WIRE
+26.5
ANY WHITE/RED WIRE
-20
ANY WHITE/BLACK/VIOLET WIRE
+20
ANY WHITE/BLACK/RED WIRE
DIAL-to-FREQ.
NOTE
instrument
does
not
Figure
5-3
for
adjustment
Table 5-2. Power Supply Adjustments
MEASUREMENT
POINT
a.
b.
c.
5-27.

POWER SUPPLY REGULATION CHECK.

a.
b.
c.
5-28.

OVEN REGULATION.

a.
This voltage will vary with oven
amplifier transistors.
b.
5-29.

FREQUENCY SYMMETRY ADJUST.

5-30.
Lower Frequency Symmetry Adj. (A13R22).
meet
a.
b.
RANGE Switch........................... X.1
CHANNEL A Function................ SQUARE
Output Attenuation ..................... Max. CW
FREQUENCY dial ...................... 1
ADJUSTMENTS
NONE
NONE
A12R20
A12R7
A12R26
A12R25
5-3
Test equipment required: AC Voltmeter (-
hp- Model 400F/FL).
With the AC Voltmeter, check the regulated
power supplies (i26. 5 V and +20.00 V) for
ripple.
Ripple should be < 20 millivolts.
Test equipment required: DC Voltmeter (-
hp- Model 3440A/3443A) and Variable Line
Voltage Transformer.
Apply
power
to
the
variable line voltage transformer.
With the DC Voltmeter, check the regulated
power supplies as input voltage to the
3300A is varied from 103 to 127 Vac (207
to 253 Vac).
Voltage limits are given in
Table 5-2.
After 3300A has been on approximately 30
min, connect a DC Voltmeter between
circuit ground and collector of Q7 (Q9 on
instruments Serial prefixed: 519-, 533-,
609-, 616- and 622-.) Voltage noted should
be approximately 20 volts.
NOTE
Turn 3300A off for approximately 1 minute,
then turn it on.
Voltage should have
decreased
to
approximately 15
Voltage
should
then
overshoot that noted in step a but in time
damp out to approximately 20 V.
Test
equipment
required:
Counter (-hp- Model 5245L with 5262A
Time Interval Plug-in).
Set 3300A controls as follows:
+40±3 V
-40±3 V
-26.5 ± 02 V
+26.5 + .02 V
-20.00+0.01 V
+20.00+. 01 V
Section V
3300Athroughthe
volts.
increase
and
Electronic
VOLTAGE
LIMITS

Hide quick links: